Refine
Document Type
- Journal article (36)
- Book chapter (2)
Language
- English (38) (remove)
Is part of the Bibliography
- yes (38)
Institute
- Life Sciences (36)
- Informatik (2)
Publisher
- De Gruyter (17)
- Macmillan Publishers Limited (3)
- Springer (3)
- American Chemical Society (2)
- CRC Press (2)
- Elsevier (2)
- MDPI (2)
- Royal Society of Chemistry (2)
- Wiley (2)
- Beilstein-Institut zur Förderung der Chemischen Wissenschaften (1)
Thermoplastic polycarbonate urethane elastomers (TPCU) are potential implant materials for treating degenerative joint diseases thanks to their adjustable rubber-like properties, their toughness, and their durability. We developed a water-containing high-molecular-weight sulfated hyaluronic acid-coating to improve the interaction of TPCU with the synovial fluid. It is suggested that trapped synovial fluid can act as a lubricant that reduces the friction forces and thus provides an enhanced abrasion resistance of TPCU implants. Aims of this work were (i) the development of a coating method for novel soft TPCU with high-molecular sulfated hyaluronic acid to increase the biocompatibility and (ii) the in vitro validation of the functionalized TPCUs in cell culture experiments.
Knee osteoarthritis is a common complication and can lead to total loss of joint function in patients. Treatment by either partial or total knee replacement with appropriate UHMWPE based implantsis highly invasive, may cause complications and may show unsatisfying results. Alternatively, treatment may be done by insertion of an elastic interpositional knee spacer with optimized material characteristics.
We report the development of high performance polyurethane-based polymers modified with bioactive molecules for fabrication of such knee spacers. In order to tailor mechanical and tribological properties and to improve resist to enzymatic degradation we propose a core-shell model for the spacer with specifically adapted properties.
Polyurethane-bases block copolymers (TPCUs) are block-copolymers with systematically varied soft and hard segments. They have been suggested to serve as material for chondral implants in joint regeneration. Such applications may require the adhesion of chondrocytes to the implant surface, facilitating cell growth while keeping their phenotype. Thus, aims of this work were (1) to modify the surface of soft biostable polyurethane-based model implants (TPCU and TSiPCU) with high-molecular weight hyaluronic acid (HA) using an optimized multistep strategy of immobilization, and (2) to evaluate bioactivity of the modified TPCUs in vitro. Our results show no cytotoxic potential of the TPCUs. HAbioactive molecules (Mw =700kDa) were immobilized onto the polyurethane surface via polyethylenimine (PEI) spacers, and modifications were confirmed by several characterization methods. Tests with porcine chondrocytes indicated the potential of the TPCU-HA for inducing enhanced cell proliferation.
Cell-cell and cell-extracellular matrix (ECM) adhesion regulates fundamental cellular functions and is crucial for cell-material contact. Adhesion is influenced by many factors like affinity and specificity of the receptor-ligand interaction or overall ligand concentration and density. To investigate molecular details of cell ECM and cadherins (cell-cell) interaction in vascular cells functional nanostructured surfaces were used Ligand-functionalized gold nanoparticles (AuNPs) with 6-8 nm diameter, are precisely immobilized on a surface and separated by non-adhesive regions so that individual integrins or cadherins can specifically interact with the ligands on the AuNPs. Using 40 nm and 90 nm distances between the AuNPs and functionalized either with peptide motifs of the extracellular matrix (RGD or REDV) or vascular endothelial cadherins (VEC), the influence of distance and ligand specificity on spreading and adhesion of endothelial cells (ECs) and smooth muscle cells (SMCs) was investigated. We demonstrate that RGD-dependent adhesion of vascular cells is similar to other cell types and that the distance dependence for integrin binding to ECM-peptides is also valid for the REDV motif. VEC-ligands decrease adhesion significantly on the tested ligand distances. These results may be helpful for future improvements in vascular tissue engineering and for development of implant surfaces.
Medical implants play a central role in modern medicine and both, naturally derived and synthetic materials have been explored as biomaterials for such devices. However, when implanted into living tissue, most materials initiate a host response. In addition, implants often cause bacterial infections leading to complications. Polyelectrolyte multilayer (PEM) coatings can be used for functionalization of medical implants improving the implant integration and reducing foreign body reactions. Some PEMs are also known to show antibacterial properties. We developed a PEM coating suggesting that it can decrease the risk of bacterial infections occurring after implantation while being highly biocompatible. We applied two different standard tests for evaluating the PEM’s antibacterial properties, the ISO norm (ISO 22196) and one ASTM norm (ASTM E2180) test. We found a reduction of bacterial growth on the PEM but to a different degree depending on the testing method. This result demonstrates the need for defining proper method to evaluate antibacterial properties of surface coatings.
Programmable nano-bio interfaces driven by tuneable vertically configured nanostructures have recently emerged as a powerful tool for cellular manipulations and interrogations. Such interfaces have strong potential for ground-breaking advances, particularly in cellular nanobiotechnology and mechanobiology. However, the opaque nature of many nanostructured surfaces makes non-destructive, live-cell characterization of cellular behavior on vertically aligned nanostructures challenging to observe. Here, a new nanofabrication route is proposed that enables harvesting of vertically aligned silicon (Si) nanowires and their subsequent transfer onto an optically transparent substrate, with high efficiency and without artefacts. We demonstrate the potential of this route for efficient live-cell phase contrast imaging and subsequent characterization of cells growing on vertically aligned Si nanowires. This approach provides the first opportunity to understand dynamic cellular responses to a cell-nanowire interface, and thus has the potential to inform the design of future nanoscale cellular manipulation technologies.
In vivo, cells encounter different physical and chemical signals in the extracellular matrix (ECM) which regulate their behavior. Examples of these signals are micro- and nanometer-sized features, the rigidity, and the chemical composition of the ECM. The study of cell responses to such cues is important to understand complex cell functions, some diseases, and is basis for the development of new biomaterials for applications in medical implants or regenerative medicine. Therefore, the development of new methods for surface modifications with controlled physical and chemical features is crucial. In this work, we report a new combination of micelle nanolithography (BCML) and soft micro-lithography, for the production of polyethylene glycol (PEG) hydrogels, with a micro-grooved surface and decoration with hexagonally precisely arranged gold nanoparticles (AU NPs). The Au-NPs are used for binding adhesive ligands in a well-defined density. First tests were performed by culturing human fibroblasts on the gels. Adhesion and alignment of the cells along the parallel grooves of the surface were investigated. The substrates could provide a new platform for studying cell contact guidance by micro structures, and may enable a more precise control of cell behavior by nanometrically controlled surface functionalization.
Surface topographies are often discussed as an important parameter influencing basic cell behavior. Whereas most in vitro studies deal with microstructures with sharp edges, smooth, curved microscale topographies might be more relevant concerning in-vivo situations. Addressing the lack of highly defined surfaces with varying curvature, we present a topography chip system with 3D curved features of varying spacing, curvature radii as well as varying overall dimensions of curved surfaces. The CurvChip is produced by low-cost photolithography with thermal reflow, subsequent (repetitive) PDMS molding and hot embossing. The platform facilitates the systematic in-vitro investigation of the impact of substrate curvature on cell types like epithelial, endothelial, smooth muscle cells, or stem cells. Such investigations will not only help to further understand the mechanism of curvature sensation but may also contribute to optimize cell-material interactions in the field of regenerative medicine.
Adapting characteristics of biomaterials specifically for in vitro and in vivo applications is becoming increasingly important in order to control interactions between material and biological systems. These complex interactions are influenced by surface properties like chemical composition, charge, mechanical and topographic attributes. In many cases it is not useful or even not possible to alter the base material but changing surface, to improve biocompatibility or to make surfaces bioactive, may be achieved by thin coatings. An already established method is the coating with polyelectrolyte multilayers (PEM). To adjust adhesion, proliferation and improve vitality of certain cell types, we modified the roughness of PEM coatings. We included different types nanoparticles (NP’s) in different concentrations into PEM coatings for controlling surface roughness. Surface properties were characterized and the reaction of 3 different cell types on these coatings was tested.
The physiology of vascular cells depends on stimulating mechanical forces caused by pulsatile flow. Thus, mechano-transduction processes and responses of primary human endothelial cells (ECs) and smooth muscle cells (SMCs) have been studied to reveal cell-type specific differences which may contribute to vascular tissue integrity. Here, we investigate the dynamic reorientation response of ECs and SMCs cultured on elastic membranes over a range of stretch frequencies from 0.01 to 1 Hz. ECs and SMCs show different cell shape adaptation responses (reorientation) dependent on the frequency. ECs reveal a specific threshold frequency (0.01 Hz) below which no responses is detectable while the threshold frequency for SMCs could not be determined and is speculated to be above 1 Hz. Interestingly, the reorganization of the actin cytoskeleton and focal adhesions system, as well as changes in the focal adhesion area, can be observed for both cell types and is dependent on the frequency. RhoA and Rac1 activities are increased for ECs but not for SMCs upon application of a uniaxial cyclic tensile strain. Analysis of membrane protrusions revealed that the spatial protrusion activity of ECs and SMCs is independent of the application of a uniaxial cyclic tensile strain of 1 Hz while the total number of protrusions is increased for ECs only. Our study indicates differences in the reorientation response and the reaction times of the two cell types in dependence of the stretching frequency, with matching data for actin cytoskeleton, focal adhesion realignment, RhoA/Rac1 activities, and membrane protrusion activity. These are promising results which may allow cell-type specific activation of vascular cells by frequency selective mechanical stretching. This specific activation of different vascular cell types might be helpful in improving strategies in regenerative medicine.