Refine
Document Type
- Journal article (5)
Language
- English (5)
Has full text
- yes (5)
Is part of the Bibliography
- yes (5)
Institute
- Life Sciences (5)
Publisher
- Wiley (5) (remove)
Escherichia coli (E. coli) is considered the most common life-threatening infectious bacteria in our daily life and poses a major challenge to human health. However, antibiotics frequently overused and misused has triggered increased multidrug resistance, hinders therapeutic outcomes, and causes higher mortalities. Herein, we addressed near-infrared (NIR) laser-excited human serum albumin (HSA) mediated graphene oxide loaded palladium nano-dots (HSA-GO-Pd) that can effectively combat Gram-negative E. coli in vitro. NIR laser-excited designed hybrid material highly generates singlet oxygen and hydroxyl radical by electron spin-resonance (ESR) analysis. Transmission electron microscope (TEM) images show small spherical sizes PdNPs on the surface of GO nano-sheets. The zeta (ζ) potential study indicates that in an aqueous medium, the average PdNPs size and surface capped charge comes from human body protein (HSA), HSA-GO-Pd is 5–8 nm, and +25 mV, respectively. The spectroscopic characterization reveals that in the synthesized HSA-GO-Pd nanocomposite, PdNPs successfully well-dispersed decorated on the surface of graphene oxide. The as-synthesized HSA-GO-Pd shows excellent antibacterial activity against gram-negative pathogen by killing 95% bacteria within 5 h. HSA-GO-Pd having very biocompatible and shows significant antibacterial activities. Owing to their intense photothermal conversation potential, low toxicity to normal cells, the as-addressed hybrid (HSA-GO-Pd) combined with NIR-irradiation will catch up valuable insight into the effective ablation of pathogenic bacteria.
Controlling the surface properties and structure of thin nanosized coatings is of primary importance in diverse engineering and medical applications. Here we report on how the nanostructure, growth mechanism, thickness, roughness, and hydrophilicity of nanocomposites composed of weak natural or strong synthetic polyelectrolytes (PE) can be tailored by graphene oxide (GO) doping. GO reverses the build‐up mechanism affecting the internal structure and the hydrophilicity in a way depending on the type of the PE‐matrix. The extent of GO‐adsorption and its impact on the surface morphology was found to be independent on the type of the underlying PE‐matrix. The nanostructure of the hybrid films is not significantly altered when a single surface‐exposed GO‐layer is deposited, while increasing the number of embedded GO‐layers leads to pronounced surface heterogeneity. These results are expected to have valuable impact on the construction strategies of coatings with tunable surface properties.
In this article, liposome-based coatings aiming to control drug release from therapeutic soft contact lenses (SCLs) materials are analyzed. A PHEMA based hydrogel material loaded with levofloxacin is used as model system for this research. The coatings are formed by polyelectrolyte layers containing liposomes of 1,2-dimyristoyl-sn-glycero-3- phosphocholine (DMPC) and DMPC1cholesterol (DMPC1 CHOL). The effect of friction and temperature on the drug release is investigated. The aim of the friction tests is to simulate the blinking of the eyelid in order to verify if the SCLs materials coated with liposomes are able to keep their properties, in particular the drug release ability. It was observed that under the study conditions, friction did not affect significantly the drug release from the liposome coated PHEMA material. In contrast, increasing the temperature of release leads to an increase of the drug diffusion rate through the hydrogel. This phenomenon is recorded both in the control and in the coated samples.
In this study, a novel strategy has been developed for the assembly of polyelectrolyte multilayer (PEM) on CaCO3 templates in acidic pH solutions, where consecutive polyelectrolyte layers (heparin/poly(allylamine hydrochloride) or heparin/chitosan) were deposited on PEM hollow microcapsules established previously on CaCO3 templates. The PEM build-up, hollow capsule characterization and successful encapsulation of fluorescein 5(6)-isothiocyanate (FITC)-Dextran by coprecipitation with CaCO3 are demonstrated. Improvement by the removal of CaCO3 core was achieved while the depositions. In the course of the release profile, high retardation for encapsulated FITC-Dextran was observed. The combined shell capsules system is a significant trait that has potential use in tailoring functional layer-by-layer capsules as intelligent drug delivery vehicles where the preliminary in vitro tests showed the responsiveness on the enzymes.
Positively charged metallic oxides prevent blood coagulation whereas negatively charged metallic oxides are thrombogenic. This study was performed to examine whether this effect extends to metallic oxide nanoparticles. Oscillation shear rheometry was used to study the effect of zinc oxide and silicon dioxide nanoparticles on thrombus formation in human whole blood. Our data show that oscillation shear rheometry is a sensitive and robust technique to analyze thrombogenicity induced by nanoparticles. Blood without previous contact with nanoparticles had a clotting time (CT) of 16.7 ± 1.0 min reaching a maximal clot strength (CS) of 16 ± 14 Pa (G') after 30 min. ZnO nanoparticles (diameter 70 nm, +37 mV zeta-potential) at a concentration of 1 mg/mL prolonged CT to 20.8 ± 3.6 min and provoked a weak clot (CS 1.5 ± 1.0 Pa). However, at a lower concentration of 100 µg/mL the ZnO particles dramatically reduced CT to 6.0 ± 0.5 min and increased CS to 171 ± 63 Pa. This procoagulant effect decreased at lower concentrations reaching the detection limit at 10 ng/mL. SiO2 nanoparticles (diameter 232 nm, −28 mV zeta-potential) at high concentrations (1 mg/mL) reduced CT (2.1 ± 0.2 min) and stimulated CS (249 ± 59 Pa). Similar to ZnO particles, this procoagulant effect reached a detection limit at 10 ng/mL. Nanoparticles in high concentrations reproduce the surface charge effects on blood coagulation previously observed with large particles or solid metal oxides. However, nanoparticles with different surface charges equally well stimulate coagulation at lower concentrations. This stimulation may be an effect which is not directly related to the surface charge.