Today 40 Gbps is in development at IEEE 802.3bq over four pair balanced cabling. In this paper, we describe a transmission experiment of 25 Gbps enabling either a single pair transmission of 25 Gbps over a 30 meter balanced cabling channel, or a 100 Gbps transmission via a four-pair balanced channel. A scalable matrix modeling tool is introduced which allows the prediction of transmission characteristics of a channel taking mode conversion into account . We applied this tool to characterize PCB-channels including the magnetics and PCB for a four-pair 100 Gbps transmission. We evaluated prototype cables and connecting hardware for frequencies up to 2 GHz and beyond. Finally we investigated possible line encoding schemes and provide measurement results of a transmission over 30 m with a data rate of 25 Gbps per twisted pair.
In this paper, research projects with 30 meter balanced cabling and data rates up to 25 Gbps over one single pair are described. The project aim is to achieve 100 Gbps via a four pair balanced cabling channel. In the following, spectral characteristics of the used prototype twisted pair are presented. Therefore, the insertion loss of the single cable in comparison to the insertion loss of the cable in combination with an equalizing amplifier, as well as the group delay of the cable and the cable connected to the equalizing amplifier is shown. Furthermore, a carrierless Pulse Amplitude Modulation with 32 different levels (PAM-32) as an approach for a possible line encoding is presented. Finally, research measurements of the data transmission with a data rate up to 25 Gbps via shielded twisted pair is shown.
Es wird gezeigt, wie bei Fernspeisung die Vorhersage der Erwärmung mit entsprechender Modellierung verbessert werden kann und wie der Einfluss von Material und Form des Kabelkanals die Erwärmung und das das Temperaturprofil des Bündels beeinflusst. Es wird auch vorgestellt, dass die erhöhte Erwärmung von Metallkabelkanälen auf die geringere Emissivität zurückzuführen ist und wie das verbessert werden kann.
Einpaarige Verkabelungssysteme gewinnen aufgrund des Internets der Dinge und aufgrund deren Einsatz im Automobil- bzw. Industriebereich zunehmend an Bedeutung. Im Rahmen dieser Arbeit wird gezeigt, wie bei der Übertragung über ein einpaariges Kabel die Bitrate bei gleichbleibender Übertragungsbandbreite durch Nutzung des Phantomkreises erhöht werden kann. Als Übertragungsverfahren kommt jeweils eine 16-stufige Pulsamplitudenmodulation zum Einsatz. Die Ergebnisse werden durch Augendiagramme qualitativ und durch die Messung der Symbolfehler bzw. der Bitfehler quantitativ untersucht.
Additive manufacturing is a key technology which applies the ideas of Industry 4.0 in order to enable the production of personalized and highly customized products economically. Especially small and medium sized companies often lack the competence and experience to evaluate objectively and profoundly the potential of additive manufacturing technologies in small and medium sized companies. Furthermore, the method has been validated in a small medical technology company evaluating the additive manufacturing potential of an existing surgery tool.
Mit der Überarbeitung der DIN EN 50173 (VDE 0800-173) Serie, wurden unter anderem die optischen Übertragungsstreckenklassen ersatzlos gestrichen. Um die so entstandene Lücke zu schließen, hat das deutsche Gremium DKE GUK 715.3 „Informationstechnische Verkabelung von Gebäudekomplexen“ neue Klassen erarbeitet, die in der DIN VDE 0800- 173-100 „Klassifizierung von Lichtwellenleiter-Übertragungsstrecken“ im Juni 2019 veröffentlicht wurden. Die Norm klassifiziert Lichtwellenleiter Übertragungsstrecken für anwendungsneutrale Kommunikationskabelanlagen nach DIN EN 50173-1.
Sie dient Benutzern, eine breite Palette von Anwendungen zu ermöglichen, die Auswahl des Verkabelungssystems zu erleichtern, eine zukunftssichere Klassifizierung von LWL-Verkabelungen zu generieren und dazu, Systemanforderungen zu beschreiben.
Die in der Norm definierten Klassen beschreiben die Anforderungen an die Übertragungsstrecken und basieren auf einer maximal zulässigen Einfügedämpfung in dB für maximale Übertragungsstreckenlängen, wobei zusätzlich das Bandbreitenlängenprodukt berücksichtigt wird.
Der Beitrag liefert einen Überblick über die Norm und zeigt Anwendungsbeispiele auf.