Despite the unstoppable global drive towards electric mobility, the electrification of sub-Saharan Africa’s ubiquitous informal multi-passenger minibus taxis raises substantial concerns. This is due to a constrained electricity system, both in terms of generation capacity and distribution networks. Without careful planning and mitigation, the additional load of charging hundreds of thousands of electric minibus taxis during peak demand times could prove catastrophic. This paper assesses the impact of charging 202 of these taxis in Johannesburg, South Africa. The potential of using external stationary battery storage and solar PV generation is assessed to reduce both peak grid demand and total energy drawn from the grid. With the addition of stationary battery storage of an equivalent of 60 kWh/taxi and a solar plant of an equivalent of 9.45 kWpk/taxi, the grid load impact is reduced by 66%, from 12 kW/taxi to 4 kW/taxi, and the daily grid energy by 58% from 87 kWh/taxi to 47 kWh/taxi. The country’s dependence on coal to generate electricity, including the solar PV supply, also reduces greenhouse gas emissions by 58%.
In the course of a more intensive energy generation from regenerative sources, an increased number of energy storages is required. In addition to the widespread means of storing electric energy, storing energy thermally can contribute significantly. However, limited research exists on the behaviour of thermal energy storages (TES) in practical operation. While the physical processes are well known, it is nevertheless often not possible to adequately evaluate its performance with respect to the quality of thermal stratification inside the tank, which is crucial for the thermodynamic effectiveness of the TES. The behaviour of a TES is experimentally investigated in cyclic charging and discharging operation in interaction with a cogeneration (CHP) unit at a test rig in the lab. From the measurements the quality of thermal stratification is evaluated under varying conditions using different metrics such as normalised stratification factor, modified MIX number, exergy number and exergy efficiency, which extends the state of art for CHP applications. The results show that the positioning of the temperature sensors for turning the CHP unit on and off has a significant influence on both the effective capacity of a TES and the quality of thermal stratification inside the tank. It is also revealed that the positioning of at least one of these sensors outside the storage tank, i.e. in the return line to the CHP unit, prevents deterioration of thermal stratification, thereby enhancing thermodynamic effectiveness. Furthermore, the effects of thermal load and thermal load profile on effective capacity and thermal stratification are discussed, even though these are much smaller compared to the effect of positioning the temperature sensors.
Flexible KWK – aber wie?
(2021)
Es ist mittlerweile unstrittig, dass Kraft-Wärme-Kopplungs-Anlagen (KWK-Anlagen) zunehmend flexible betrieben werden müssen. Nur so kann es gelingen, die Anlagen optimal in das elektrische Energiesystem einzubinden, beispielsweise zur Deckung der Residuallast oder zur Unterstützung der Verteilnetze, und damit zur Umsetzung der Energiewende beizutragen. Auch der Gesetzgeber fordert den flexiblen Betrieb durch die Absenkung der förderfähigen Betriebsstunden im KWK-Gesetz ein. Um vor diesem Hintergrund jedoch parallel die Deckung des erforderlichen Wärmebedarfs unter Gewährleistung der hohen Effizienz der KWK sicherzustellen, ist eine intelligente Steuerung der Geräte erforderlich. Zu diesem Zweck ist an der Hochschule Reutlingen ein vorausschauender Steuerungsalgorithmus zum „stromoptimierten“ und netzdienlichen“ Betrieb von KWK-Anlagen bei voller Nutzung der KWK-Wärme als Alternative zum standardmäßig anzutreffenden wärmegeführten Betrieb entwickelt worden.
This paper covers test and verification of a forecast-based Monte Carlo algorithm for an optimized, demand-oriented operation of combined heat and power (CHP) units using the hardware-in-the-loop approach. For this purpose, the optimization algorithm was implemented at a test bench at Reutlingen University for controlling a CHP unit in combination with a thermal energy storage, both in real hardware. In detail, the hardware-in-the-loop tests are intended to reveal the effects of demand forecasting accuracy, the impact of thermal energy storage capacity and the influence of load profiles on demand-oriented operation of CHP units. In addition, the paper focuses on the evaluation of the content of energy in the thermal energy storage under practical conditions. It is shown that a 5-layer model allows to determine the energy stored quite accurately, which is verified by experimental results. The hardware-in-the-loop tests disclose that demand forecasting accuracies, especially electricity demand forecasting, as well as load profiles strongly impact the potential for CHP electricity utilization on-site in demand-oriented mode. Moreover, it is shown that a larger effective capacity of the thermal energy storage positively affects demand-oriented operation. In the hardware-in-the-loop tests, the fraction of electricity generated by the CHP unit utilized on-site could thus be increased by a maximum of 27% compared to heat-led operation, which is still the most common modus operandi of small-scale CHP plants. Hence, the hardware-in-the-loop tests were adequate to prove the significant impact of the proposed algorithm for optimization of demand-oriented operation of CHP units.
Heat pumps are a vital element for reaching the greenhouse gas (GHG) reduction targets in the heating sector, but their system integration requires smart control approaches. In this paper, we first offer a comprehensive literature review and definition of the term control for the described context. Additionally, we present a control approach, which consists of an optimal scheduling module coupled with a detailed energy system simulation module. The aim of this integrated two part control approach is to improve the performance of an energy system equipped with a heat pump, while recognizing the technical boundaries of the energy system in full detail. By applying this control to a typical family household situation, we illustrate that this integrated approach results in a more realistic heat pump operation and thus a more realistic assessment of the control performance, while still achieving lower operational costs.
Heat pumps in combination with a photovoltaic system are a very promising option for the transformation of the energy system. By using such a system for coupling the electricity and heat sectors, buildings can be heated sustainably and with low greenhouse gas emissions. This paper reveals a method for dimensioning a suitable system of heat pump and photovoltaics (PV) for residential buildings in order to achieve a high level of (photovoltaic) PV self-consumption. This is accomplished by utilizing a thermal energy storage (TES) for shifting the operation of the heat pump to times of high PV power production by an intelligent control algorithm, which yields a high portion of PV power directly utilized by the heat pump. In order to cover the existing set of building infrastructure, 4 reference buildings with different years of construction are introduced for both single- and multi-family residential buildings. By this means, older buildings with radiator heating as well as new buildings with floor heating systems are included. The simulations for evaluating the performance of a heat pump/PV system controlled by the novel algorithm for each type of building were carried out in MATLAB-Simulink® 2017a. The results show that 25.3% up to 41.0% of the buildings’ electricity consumption including the heat pump can be covered directly from the PV installation per year. Evidently, the characteristics of the heating system significantly influence the results: new buildings with floor heating and low supply temperatures yield a higher level of PV self-consumption due to a higher efficiency of the heat pump compared to buildings with radiator heating and higher supply temperatures. In addition, the effect of adding a battery to the system was studied for two building types. It will be shown that the degree of PV self-consumption increases in case a battery is present. However, due to the high investment costs of batteries, they do not pay off within a reasonable period.
Das Thema Energieflexibilität und Anpassung der eigenerzeugten Energie an die Energieerzeugung aus regenerativen Energien gewinnt an Bedeutung. Regulierbare Eigenerzeugungsanlagen können zur Stabilisierung des Netzes einen enormen Beitrag leisten. Der Aufsatz zeigt, welchen Effekt der Einsatz von BHWK auf die Galvanikbranche hat und wie nicht nur die eigenen Energiekosten reduziert, sondern auch die Möglichkeit geschaffen wird, auf Signale der Energiewirtschaft zu reagieren, ohne die Energieversorgung zu unterbrechen.
Nowadays CHP units are discussed for the production of electricity on demand rather than for generation of heat providing electricity as a by-product. By this means, CHP units are capable of satisfying a higher share of the electricity demand on-site and in this new role, CHP units are able to reduce the load on the power grid and to compensate for high fluctuations of solar and wind power.
Evidently, a novel control strategy for CHP units is required in order to shift the operation oriented at the heat demand to an operation led by the electricity demand. Nevertheless, the heat generated by the CHP unit needs to be utilized completely in any case, for maintaining energy as well as economic efficiency. Such a strategy has been developed at Reutlingen University, and it will be presented in the paper. Part of the strategy is an intelligent management for the thermal energy storage (TES) ensuring that the storage is at low level in terms of its heat content just before an electricity demand is calling the CHP unit into operation. Moreover, a proper forecast of both, heat and electricity demand, is incorporated and the requirements of the CHP unit in terms of maintenance and lifetime are considered by limiting the number of starts and stops per unit time and by maintaining a certain minimum length of the operation intervals.
All aspects of this novel control strategy are revealed in the paper, which has been implemented on a controller for further testing at two sites in the field. Results from these tests are given as well as results from a simulation model, which is able to evaluate the performance of the control strategy for an entire year.
Das Thema Energiewende ist in aller Munde. Sie soll eine sichere, umweltverträgliche und wirtschaftlich erfolgreiche Zukunft ermöglichen. Ein Ansatz dafür ist die dezentrale, also verbrauchernahe Energieversorgung. Der Trend geht weg vom konventionellen Kraftwerk und hin zur Kraft-Wärme-Koppelung und erneuerbaren Energien. Für einen absehbaren Zeitraum geht es auch darum, zentrale und dezentrale Elemente sinnvoll miteinander zu verknüpfen. Mit der Frage, wie Energiesysteme angepasst und kombiniert werden müssen, um den Energiehaushalt – den nationalen wie den von Unternehmen und Privatpersonen – optimieren zu können, beschäftigt sich das Reutlinger Energiezentrum für Dezentrale Energiesysteme und Energieeffizienz in Lehre und Forschung. Es ist die Kombination aus Technik und Betriebswirtschaft, aus einzelwirtschaftlicher Optimierung und aus Gesamtsicht, die das Reutlinger Energiezentrum ausmacht. Im Folgenden werden die Schwerpunkte des Forschungsteams dargestellt.
Virtuelle Kraftwerke bieten durch große Flexibilitätspotentiale die Chance, die Integration fluktuierender, erneuerbarer Energieerzeuger zu ermöglichen und dadurch die Netzstabilität positiv zu beeinflussen. Für einen wirtschaftlichen Betrieb virtueller Kraftwerke sind jedoch neue Geschäftsmodelle notwendig. Der folgende Artikel behandelt die Anforderung an Geschäftsmodelle für virtuelle Kraftwerke sowie konkrete Ausgestaltungsmöglichkeiten eines Marktes, der auf virtuelle Kraftwerke ausgerichtet ist. Die Untersuchungen wurden im Rahmen einer Projektarbeit im Masterstudiengang SENCE an der Hochschule Reutlingen im Forschungsprojekt „Virtuelles Kraftwerk Neckar- Alb“ durchgeführt. Das „Virtuelle Kraftwerk Neckar- Alb“ wird vom BMWi als Kooperationsnetzwerkprojekt im Rahmen der Förderlinie ZIM-KN unterstützt.