Refine
Document Type
- Journal article (15)
Language
- English (15)
Has full text
- yes (15) (remove)
Is part of the Bibliography
- yes (15)
Institute
- Life Sciences (15)
Publisher
- MDPI (5)
- American Chemical Society (3)
- De Gruyter (2)
- IIAR (2)
- Wiley (2)
- Frontiers Media (1)
In this study, a novel strategy has been developed for the assembly of polyelectrolyte multilayer (PEM) on CaCO3 templates in acidic pH solutions, where consecutive polyelectrolyte layers (heparin/poly(allylamine hydrochloride) or heparin/chitosan) were deposited on PEM hollow microcapsules established previously on CaCO3 templates. The PEM build-up, hollow capsule characterization and successful encapsulation of fluorescein 5(6)-isothiocyanate (FITC)-Dextran by coprecipitation with CaCO3 are demonstrated. Improvement by the removal of CaCO3 core was achieved while the depositions. In the course of the release profile, high retardation for encapsulated FITC-Dextran was observed. The combined shell capsules system is a significant trait that has potential use in tailoring functional layer-by-layer capsules as intelligent drug delivery vehicles where the preliminary in vitro tests showed the responsiveness on the enzymes.
Polyelectrolyte multi-layer (PEM) coatings are prepared by alternative deposition of single polyelectrolyte monolayers on charged surfaces using the Layer-by-Layer (LbL) dip coating procedure. These are nanometre scaled coatings which allow fulfilling of different technical or biological requirements. The build-up process is based on selfassembly and self organization of polycations and polyanions on different substrates including complex geometrical structures and even closed volumes, forming homogeneous layer without defects. Depending on the proper selection of the applied polyelectrolytes, coatings with different stabilities can be prepared. Some of the coatings are stable and cannot be removed from the surface. Others are degradable and can be used as systems for controlled local drug delivery. Here we summarise the results of our experience in preparation of PEM coatings with different functionalities. PEM coatings can be used as controllable delivery system for siRNA polyplexes. They can be used to control the adhesion of different cell types on the surfaces and support e.g. the endothelialisation process on cardio-vascular medical devices as e.g. stents or reduce the immunological response of the tissue after implantation. We summarise results from physical characterisation of the coatings (e.g. film thickness, roughness, electrical charge and hydrophilicity) combined with in-vitro biological studies on adhesion of HUVEC cells.
High moisture permeability, excellent mechanical properties in a wet state, high water-holding capability, and high exudate absorption make bacterial nanocellulose (BNC) a favorable candidate for biomedical device production, especially wound dressings. The lack of antibacterial activity and healing-promoting ability are the main drawbacks that limit its wide application. Pullulan (Pul) is a nontoxic polymer that can promote wound healing. Zinc oxide nanoparticles (ZnO-NPs) are well-known as a safe antibacterial agent. In this study, aminoalkylsilane was chemically grafted on a BNC membrane (A-g-BNC) and used as a bridge to combine BNC with Pul-ZnO-NPs hybrid electrospun nanofibers. FTIR results confirmed the successful production of A-g-BNC/Pul-ZnO. The obtained dressing demonstrated blood clotting performance better than that of BNC. The dressing showed an ability to release ZnO, and its antibacterial activity was up to 5 log values higher than that of BNC. The cytotoxicity of the dressing toward L929 fibroblast cells clearly showed safety due to the proliferation of fibroblast cells. The animal test in a rat model indicated faster healing and re-epithelialization, small blood vessel formation, and collagen synthesis in the wounds covered by A-g-BNC/Pul-ZnO. The new functional dressing, fabricated with a cost-effective and easy method, not only showed excellent antibacterial activity but could also accelerate wound healing.
Controlled adhesion of HUVEC on polyelectrolyte multilayers by regulation of coating conditions
(2021)
Adhesion of host cells on the surface of implants is necessary for a healthy ingrowth of the implanted material. One possibility of surface modification is the coating of the implant with a second material with advantageous physical–chemical surface properties for the biological system. The coverage with blood proteins takes place immediately after implantation. It is followed by host–cell interaction on the surface. In this work, the effect of polyelectrolyte multilayer coatings (PEMs) on adhesion and activity of human umbilical vein endothelial cells (HUVECs) was studied. The PEMs were formed from poly(styrenesulfonate) (PSS) and poly(allylamine hydrochloride) (PAH) from solutions with different concentrations of NaCl varying between 0 and 1.0 M. The adhesion of HUVEC and their viability on the PEM is related to the amount of adsorbed proteins from the applied cell growth medium. The amount of adsorbed proteins is controlled not only by the surface charge but also by the internal excess charge of the PEM. The internal excess charge of the PEM was controlled by changing the electrolyte concentration in the deposition solutions.
The present publication reports the purification effort of two natural bone blocks, that is, an allogeneic bone block (maxgraft®, botiss biomaterials GmbH, Zossen, Germany) and a xenogeneic block (SMARTBONE®, IBI S.A., Mezzovico Vira, Switzerland) in addition to previously published results based on histology. Furthermore, specialized scanning electron microscopy (SEM) and in vitro analyses (XTT, BrdU, LDH) for testing of the cytocompatibility based on ISO 10993-5/-12 have been conducted. The microscopic analyses showed that both bone blocks possess a trabecular structure with a lamellar subarrangement. In the case of the xenogeneic bone block, only minor remnants of collagenous structures were found, while in contrast high amounts of collagen were found associated with the allogeneic bone matrix. Furthermore, only island-like remnants of the polymer coating in case of the xenogeneic bone substitute seemed to be detectable. Finally, no remaining cells or cellular remnants were found in both bone blocks. The in vitro analyses showed that both bone blocks are biocompatible. Altogether, the purification level of both bone blocks seems to be favorable for bone tissue regeneration without the risk for inflammatory responses or graft rejection. Moreover, the analysis of the maxgraft® bone block showed that the underlying purification process allows for preserving not only the calcified bone matrix but also high amounts of the intertrabecular collagen matrix.
Background/Aim: The aim of this study was the development of a new osteoconductivity index to determine the bone healing capacities of bone substitute materials (BSM) on the basis of 3D microcomputed tomographic (μ-CT) data. Materials and Methods: Sinus biopsies were used for the comparative analysis of the integration behavior of two xenogeneic BSM (cerabone® and Bio Oss®). 3D μ-CT and data sets from histomorphometrical measurements based on 2D histological slices were used to measure the bone-material-contact and the tissue distribution within the biopsies. The tissue reactions to both BSM were microscopically analyzed. Results: The 3D and 2D results of the osteoconductivity measurements showed comparable material-bone contacts for both BSM, but the 2D data were significantly lower. The same results were found when tissue distribution was measured in both groups. The histopathological analysis showed comparative tissue reactions in both BSM. Conclusion: Osteoconductivity index is a reliable measurement parameter for determining the healing capacities of BSM. The observed differences between both measurement methods could be assigned to the resolution capacity of μ-CT data that did not allow for a precise interface distinction between both BSM and bone tissue. Histomorphometrical data based on histological slides still allow for a more exact evaluation.
Medical implants play a central role in modern medicine and both, naturally derived and synthetic materials have been explored as biomaterials for such devices. However, when implanted into living tissue, most materials initiate a host response. In addition, implants often cause bacterial infections leading to complications. Polyelectrolyte multilayer (PEM) coatings can be used for functionalization of medical implants improving the implant integration and reducing foreign body reactions. Some PEMs are also known to show antibacterial properties. We developed a PEM coating suggesting that it can decrease the risk of bacterial infections occurring after implantation while being highly biocompatible. We applied two different standard tests for evaluating the PEM’s antibacterial properties, the ISO norm (ISO 22196) and one ASTM norm (ASTM E2180) test. We found a reduction of bacterial growth on the PEM but to a different degree depending on the testing method. This result demonstrates the need for defining proper method to evaluate antibacterial properties of surface coatings.
Introduction: Bioresorbable collagenous barrier membranes are used to prevent premature soft tissue ingrowth and to allow bone regeneration. For volume stable indications, only non-absorbable synthetic materials are available. This study investigates a new bioresorbable hydrofluoric acid (HF)-treated magnesium (Mg) mesh in a native collagen membrane for volume stable situations. Materials and Methods: HF-treated and untreated Mg were compared in direct and indirect cytocompatibility assays. In vivo, 18 New Zealand White Rabbits received each four 8 mm calvarial defects and were divided into four groups: (a) HF-treated Mg mesh/collagen membrane, (b) untreated Mg mesh/collagen membrane (c) collagen membrane and (d) sham operation. After 6, 12 and 18 weeks, Mg degradation and bone regeneration was measured using radiological and histological methods. Results: In vitro, HF-treated Mg showed higher cytocompatibility. Histopathologically, HF-Mg prevented gas cavities and was degraded by mononuclear cells via phagocytosis up to 12 weeks. Untreated Mg showed partially significant more gas cavities and a fibrous tissue reaction. Bone regeneration was not significantly different between all groups. Discussion and Conclusions: HF-Mg meshes embedded in native collagen membranes represent a volume stable and biocompatible alternative to the non-absorbable synthetic materials. HF-Mg shows less corrosion and is degraded by phagocytosis. However, the application of membranes did not result in higher bone regeneration.
Background/Aim: The aim of this study was the conception, production, material analysis and cytocompatibility analysis of a new collagen foam for medical applications. Materials and Methods: After the innovative production of various collagen sponges from bovine sources, the foams were analyzed ex vivo in terms of their structure (including pore size) and in vitro in terms of cytocompatibility according to EN ISO 10993-5/-12. In vitro, the collagen foams were compared with the established soft and hard tissue materials cerabone and Jason membrane (both botiss biomaterials GmbH, Zossen, Germany). Results: Collagen foams with different compositions were successfully produced from bovine sources. Ex vivo, the foams showed a stable and long-lasting primary structure quality with a bubble area of 1,000 to 2,000 μm2. In vitro, all foams showed sufficient cytocompatibility. Conclusion: Collagen sponges represent a promising material for hard and soft tissue regeneration. Future studies could focus on integrating and investigating different additives in the foams.
Escherichia coli (E. coli) is considered the most common life-threatening infectious bacteria in our daily life and poses a major challenge to human health. However, antibiotics frequently overused and misused has triggered increased multidrug resistance, hinders therapeutic outcomes, and causes higher mortalities. Herein, we addressed near-infrared (NIR) laser-excited human serum albumin (HSA) mediated graphene oxide loaded palladium nano-dots (HSA-GO-Pd) that can effectively combat Gram-negative E. coli in vitro. NIR laser-excited designed hybrid material highly generates singlet oxygen and hydroxyl radical by electron spin-resonance (ESR) analysis. Transmission electron microscope (TEM) images show small spherical sizes PdNPs on the surface of GO nano-sheets. The zeta (ζ) potential study indicates that in an aqueous medium, the average PdNPs size and surface capped charge comes from human body protein (HSA), HSA-GO-Pd is 5–8 nm, and +25 mV, respectively. The spectroscopic characterization reveals that in the synthesized HSA-GO-Pd nanocomposite, PdNPs successfully well-dispersed decorated on the surface of graphene oxide. The as-synthesized HSA-GO-Pd shows excellent antibacterial activity against gram-negative pathogen by killing 95% bacteria within 5 h. HSA-GO-Pd having very biocompatible and shows significant antibacterial activities. Owing to their intense photothermal conversation potential, low toxicity to normal cells, the as-addressed hybrid (HSA-GO-Pd) combined with NIR-irradiation will catch up valuable insight into the effective ablation of pathogenic bacteria.