Refine
Document Type
- Conference proceeding (3) (remove)
Language
- English (3)
Has full text
- yes (3)
Is part of the Bibliography
- yes (3)
Institute
- Technik (3)
Publisher
- IEEE (2)
- Newcastle University (1)
The main challenge when driving heat pumps by PV-electricity is balancing differing electrical and thermal demands. In this article, a heuristic method for optimal operation of a heat pump driven by a maximum share of PV-electricity is presented. For this purpose, the (DHW) are activated in order shift the operation of the heat pump to times of PV-generation. The system under consideration refers to thermal and electrical demands of a single family house. It consists of a heat pump, a thermal energy storage for DHW and of grid connected heating and generation of domestic hot water, the heat pump runs with two different supply temperatures and thereby achieving a maximum overall COP. Within the algorithm for optimization a set of heuristic rules is developed in a way that the operational characteristics of the heat pump in terms of minimum running and stopping times are met as well as the limiting constraints of upper and lower limits of room temperature and energy content of electricity generated, a varying number of heat pump schedules fulfilling the bundary conditions are created. Finally, the schedule offering the maximum on-site utilization of PV-electricity with a minimum number of starts of the heat pump, which serves as secondary condition, is selected. Yearly simulations of this combination have been carried out. Initial results of this method indicate a significant rise in on-site consumption of the PV-electricity and heating demand fulfilment by renewable electricity with no need for a massive TES for the heating system in terms of a big water tank.
Micro grids often consist of energy generators, storages and consumers with controllers which are not prepared for their integration into communication networks for energy systems. In this paper it will be presented, how standards from the field of energy automation can be applied in such controllers. The data for communication interfaces can be structured according to the IEC 61850- or the VHPREADY standard. It is investigated which requirements must be supported to implement such data models within the controllers. For the transmission of the data we propose the OPC UA protocol, which supports extensive security measures and which is today available for nearly all modern types of controllers and computers.
This article presents a two-level optimisation approach for the management of controllable and distributed converters with storage systems across different energy sectors. It aims at the reduction of electrical peak load and at the economical optimisation of the electrical energy exchange with the grid, based on a dynamic external incentive, e.g. through dynamic energy price tariffs. By means of a secure, standardised and lean communication with two different internal price signals, an optimal flexibility provision shall be achieved. The two-level optimisation approach consists of a centralised and several distributed decentralised entities. At the centralised level, the distributed flexibilities are invoked for optimal scheduling on the basis of an internal price algorithm for stimulating the decentralised entities. Based on that internal incentive and on the expected demands for electricity, heating and cooling, the decentralised optimisation algorithms provide optimal generation schedules for the energy converters. The suggested interaction between the central and decentral entities is successfully tested and the principle potential for peak shaving and the adaption to dynamic energy-related market prices could be demonstrated and compared to different energy management strategies such as the standard heat-led operation. Further, variations of the system parameters such as load shifting potential, installed capacity and system diversification are evaluated against cost saving potential for the energy supply and overall system performance.