Refine
Year of publication
- 2021 (4) (remove)
Document Type
- Journal article (3)
- Conference proceeding (1)
Is part of the Bibliography
- yes (4)
Institute
- Technik (4) (remove)
Publisher
- Elsevier (1)
- Heizungs-Journal Verlags-GmbH (1)
- VDE Verlag (1)
- VDI Fachmedien (1)
The integration of renewable energy sources in single family homes is challenging. Advance knowledge of the demand of electrical energy, heat, and domestic hot water (DHW) is useful to schedule projectable devices like heat pumps. In this work, we consider demand time series for heat and DHW from 2018 for a single family home in Germany. We compare different forecasting methods to predict such demands for the next day. While the 1-day-back forecast method led to the prediction of heat demand, the N-day-average performed best for DHW demand when Unbiased Exponentially Moving Average (UEMA) is used with a memory of 2.5 days. This is surprising as these forecasting methods are very simple and do not leverage additional information sources such as weather forecasts.
Flexible KWK – aber wie?
(2021)
Es ist mittlerweile unstrittig, dass Kraft-Wärme-Kopplungs-Anlagen (KWK-Anlagen) zunehmend flexible betrieben werden müssen. Nur so kann es gelingen, die Anlagen optimal in das elektrische Energiesystem einzubinden, beispielsweise zur Deckung der Residuallast oder zur Unterstützung der Verteilnetze, und damit zur Umsetzung der Energiewende beizutragen. Auch der Gesetzgeber fordert den flexiblen Betrieb durch die Absenkung der förderfähigen Betriebsstunden im KWK-Gesetz ein. Um vor diesem Hintergrund jedoch parallel die Deckung des erforderlichen Wärmebedarfs unter Gewährleistung der hohen Effizienz der KWK sicherzustellen, ist eine intelligente Steuerung der Geräte erforderlich. Zu diesem Zweck ist an der Hochschule Reutlingen ein vorausschauender Steuerungsalgorithmus zum „stromoptimierten“ und netzdienlichen“ Betrieb von KWK-Anlagen bei voller Nutzung der KWK-Wärme als Alternative zum standardmäßig anzutreffenden wärmegeführten Betrieb entwickelt worden.
Für die erfolgreiche Umsetzung der Energiewende in Deutschland ist die Kraft-Wärme-Kopplung (KWK) aufgrund ihrer hohen Effizienz und Flexibilität nicht mehr wegzudenken. Um die verfügbare Flexibilität einer KWK-Anlage unter Gewährleistung ihrer hohen Effizienz optimal nutzen zu können, ist an der Hochschule Reutlingen in mehrjährigen Forschungsarbeit ein prognosebasierter Steuerungsalgorithmus für Blockheizkraftwerke (BHKW) in Verbindung mit Wärmespeichern entwickelt worden.
This paper covers test and verification of a forecast-based Monte Carlo algorithm for an optimized, demand-oriented operation of combined heat and power (CHP) units using the hardware-in-the-loop approach. For this purpose, the optimization algorithm was implemented at a test bench at Reutlingen University for controlling a CHP unit in combination with a thermal energy storage, both in real hardware. In detail, the hardware-in-the-loop tests are intended to reveal the effects of demand forecasting accuracy, the impact of thermal energy storage capacity and the influence of load profiles on demand-oriented operation of CHP units. In addition, the paper focuses on the evaluation of the content of energy in the thermal energy storage under practical conditions. It is shown that a 5-layer model allows to determine the energy stored quite accurately, which is verified by experimental results. The hardware-in-the-loop tests disclose that demand forecasting accuracies, especially electricity demand forecasting, as well as load profiles strongly impact the potential for CHP electricity utilization on-site in demand-oriented mode. Moreover, it is shown that a larger effective capacity of the thermal energy storage positively affects demand-oriented operation. In the hardware-in-the-loop tests, the fraction of electricity generated by the CHP unit utilized on-site could thus be increased by a maximum of 27% compared to heat-led operation, which is still the most common modus operandi of small-scale CHP plants. Hence, the hardware-in-the-loop tests were adequate to prove the significant impact of the proposed algorithm for optimization of demand-oriented operation of CHP units.