Refine
Document Type
- Journal article (9)
Language
- English (9)
Is part of the Bibliography
- yes (9)
Institute
- Life Sciences (9)
Publisher
- IOP Publishing (5)
- Springer (2)
- Elsevier (1)
- Lippincott Williams & Wilkins (1)
Background: Multicapillary column ion-mobility spectrometry (MCC-IMS) may identify volatile components in exhaled gas. The authors therefore used MCC-IMS to evaluate exhaled gas in a rat model of sepsis, inflammation, and hemorrhagic shock.
Methods: Male Sprague-Dawley rats were anesthetized and ventilated via tracheostomy for 10 h or until death. Sepsis was induced by cecal ligation and incision in 10 rats; a sham operation was performed in 10 others. In 10 other rats, endotoxemia was induced by intravenous administration of 10 mg/kg lipopolysaccharide. In a final 10 rats, hemorrhagic shock was induced to a mean arterial pressure of 35 +/- 5 mmHg. Exhaled gas was analyzed with MCC-IMS, and volatile compounds were identified using the BS-MCC/IMS-analytes database (Version 1209; B&S Analytik, Dortmund, Germany).
Results: All sham animals survived the observation period, whereas mean survival time was 7.9 h in the septic animals, 9.1 h in endotoxemic animals, and 2.5 h in hemorrhagic shock. Volatile compounds showed statistically significant differences in septic and endotoxemic rats compared with sham rats for 3-pentanone and acetone. Endotoxic rats differed significantly from sham for 1-propanol, butanal, acetophenone, 1,2-butandiol, and 2-hexanone. Statistically significant differences were observed between septic and endotoxemic rats for butanal, 3-pentanone, and 2-hexanone. 2-Hexanone differed from all other groups in the rats with shock.
Conclusions: Breath analysis of expired organic compounds differed significantly in septic, inflammation, and sham rats. MCC-IMS of exhaled breath deserves additional study as a noninvasive approach for distinguishing sepsis from inflammation.
In breath analysis, ambient air contaminations are ubiquitous and difficult to eliminate. This study was designed to investigate the reduction of ambient air background by a lung wash-out with synthetic air. The reduction of the initial ambient air volatile organic compound (VOC) intensity was investigated in the breath of 20 volunteers inhaling synthetic air via a sealed full face mask in comparison to inhaling ambient air. Over a period of 30 minutes, breath analysis was conducted using ion mobility spectrometry coupled to a multi-capillary column. A total of 68 VOCs were identified for inhaling ambient air or inhaling synthetic air. By treatment with synthetic air, 39 VOCs decreased in intensity, whereas 29 increased in comparison to inhaling ambient air. In total, seven VOCs were significantly reduced (P-value < 0.05). A complete wash-out of VOCs in this setting was not observed, whereby a statistically significant reduction up to 65% as for terpinolene was achieved. Our setting successfully demonstrated a reduction of ambient air contaminations from the airways by a lung wash-out with synthetic air.
Online measurement of drug concentrations in patient's breath is a promising approach for individualized dosage. A direct transfer from breath- to blood-concentrations is not possible. Measured exhaled concentrations are following the blood-concentration with a delay in non-steady-state situations. Therefore, it is necessary to integrate the breath-concentration into a pharmacological model. Two different approaches for pharmacokinetic modelling are presented. Usually a 3-compartment model is used for pharmacokinetic calculations of blood concentrations. This 3-compartment model is extended with a 2-compartment model based on the first compartment of the 3-compartment model and a new lung compartment. The second approach is to calculate a time delay of changes in the concentration of the first compartment to describe the lung-concentration. Exemplarily both approaches are used for modelling of exhaled propofol. Based on time series of exhaled propofol measurements using an ion-mobility-spectrometer every minute for 346 min a correlation of calculated plasma and the breath concentration was used for modelling to deliver R2 = 0.99 interdependencies. Including the time delay modelling approach the new compartment coefficient ke0lung was calculated to ke0lung = 0.27 min−1 with R2 = 0.96. The described models are not limited to propofol. They could be used for any kind of drugs, which are measurable in patient's breath.
Rats are commonly used in medical research as they enable a high grade of standardization. The exhalome of ventilated rats has not as yet been investigated using an ion mobility spectrometer coupled with a multi-capillary column (MCC-IMS). As a first step, a rat model has to be established to measure potential biomarkers in the exhale with long-term settings, allowing constant and continuous analysis of exhaled air in time series. Therefore, eight animals were anaesthetized, prepared and ventilated for 1 h. A total of 73 peaks were directly detected with the IMS chromatogram. Thirty five of them were assigned to the ventilator system and 38 to the animals. Peak intensity varied within three measurements. The intensity of analytes of individual rats varied by a factor of up to 18. This new model will also enable continuous measurements of volatile organic compounds (VOCs) from rat's breath in long-term experiments. It is hoped that, in the future, variability and progression of VOCs can be monitored in different models of diseases using this set-up.
The analysis of exhaled metabolites has become a promising field of research in recent decades. Several volatile organic compounds reflecting metabolic disturbance and nutrition status have even been reported. These are particularly important for long-term measurements, as needed in medical research for detection of disease progression and therapeutic efficacy. In this context, it has become urgent to investigate the effect of fasting and glucose treatment for breath analysis. In the present study, we used amodel of ventilated rats that fasted for 12 h prior to the experiment. Ten rats per group were randomly assigned for continuous intravenous infusion without glucose or an infusion including 25 mg glucose per 100 g per hour during an observation period of 12 h. Exhaled gas was analysed using multicapillary column ion-mobility spectrometry. Analytes were identified by the BS-MCC/IMS database (version 1209; B & S Analytik, Dortmund, Germany). Glucose infusion led to a significant increase in blood glucose levels (p<0.05 at 4 h and thereafter) and cardiac output (p<0.05 at 4 h and thereafter). During the observation period, 39 peaks were found collectively. There were significant differences between groups in the concentration of ten volatile organic compounds: p<0.001 at 4 h and thereafter for isoprene, cyclohexanone, acetone, p-cymol, 2-hexanone, phenylacetylene, and one unknown compound, and p<0.001 at 8 h and thereafter for 1-pentanol, 1-propanol, and 2-heptanol. Our results indicate that for long-term measurement, fasting and the withholding of glucose could contribute to changes of volatile metabolites in exhaled air.
Influence of the respirator on volatile organic compounds : an animal study in rats over 24 hours
(2015)
Long-term animal studies are needed to accomplish measurements of volatile organic compounds (VOCs) for medical diagnostics. In order to analyze the time course of VOCs, it is necessary to ventilate these animals. Therefore, a total of 10 male Sprague–Dawley rats were anaesthetized and ventilated with synthetic air via tracheotomy for 24 h. An ion mobility spectrometry coupled to multi-capillary columns (MCC–IMS) was used to analyze the expired air. To identify background contaminations produced by the respirator itself, six comparative measurements were conducted with ventilators only. Overall, a number of 37 peaks could be detected within the positive mode. According to the ratio peak intensity rat/ peak intensity ventilator blank, 22 peaks with a ratio >1.5 were defined as expired VOCs, 12 peaks with a ratio between 0.5 and 1.5 as unaffected VOCs, and three peaks with a ratio <0.5 as resorbed VOCs. The peak intensity of 12 expired VOCs changed significantly during the 24 h measurement. These results represent the basis for future intervention studies. Notably, online VOC analysis with MCC–IMS is possible over 24 h in ventilated rats and allows different experimental approaches.
Propofol is an intravenous anesthetic. Currently, it is not possible to routinely measure blood concentration of the drug in real time. However, multi-capillary column ion-mobility spectrometry of exhaled gas can estimate blood propofol concentration.Unfortunately, adhesion of volatile propofol on plastic materials complicates measurements. Therefore, it is necessary to consider the extent to which volatile propofol adheres to various plastics used in sampling tubing. Perfluoralkoxy (PFA), polytetrafluorethylene (PTFE), polyurethane (PUR), silicone, and Tygon tubing were investigated in an experimental setting using a calibration gas generator (HovaCAL). Propofol gas was measured for one hour at 26 °C, 50 °C, and 90 °C tubing temperature. Test tubing segments were then flushed with N2 to quantify desorption. PUR and Tygon sample tubing absorbed all volatile propofol. The silicone tubing reached the maximum propofol concentration after 119 min which was 29 min after propofol gas exposure stopped. The use of PFAor PTFE tubing produced comparable and reasonably accurate propofol measurements. The desaturation time for the PFA was 10 min shorter at 26 °C than for PTFE. PFA tubing thus seems most suitable for measurement of volatile propofol,with PTFE as an alternative.
Propofol is a commonly used intravenous general anesthetic. Multi-capillary column (MCC) coupled ion-mobility spectrometry (IMS) can be used to quantify exhaled propofol, and thus estimate plasma drug concentration. Here, we present results of the calibration and analytical validation of a MCC/IMS pre-market prototype for propofol quantification in exhaled air.
Propofol in exhaled breath can be measured and may provide a real-time estimate of plasma concentration. However, propofol is absorbed in plastic tubing, thus estimates may fail to reflect lung/blood concentration if expired gas is not extracted directly from the endotracheal tube.We evaluated exhaled propofol in five ventilated ICU patients who were sedated with propofol. Exhaled propofol was measured once per minute using ion mobility spectrometry. Exhaled air was sampled directly from the endotracheal tube and at the ventilator end of the expiratory side of the anesthetic circuit. The circuit was disconnected from the patient and propofol was washed out with a separate clean ventilator. Propofol molecules, which discharged from the expiratory portion of the breathing circuit, were measured for up to 60 h.We also determined whether propofol passes through the plastic of breathing circuits. A total of 984 data pairs (presented as median values, with 95% confidence interval), consisting of both concentrations were collected. The concentration of propofol sampled near the patient was always substantially higher, at 10.4 [10.25–10.55] versus 5.73 [5.66–5.88] ppb (p<0.001). The reduction in concentration over the breathing circuit tubing was 4.58 [4.48–4.68] ppb, 3.46 [3.21–3.73] in the first hour, 4.05 [3.77–4.34] in the second hour, and 4.01 [3.36–4.40] in the third hour. Out-gassing propofol from the breathing circuit remained at 2.8 ppb after 60 h of washing out. Diffusion through the plastic was not observed. Volatile propofol binds or adsorbs to the plastic of a breathing circuit with saturation kinetics. The bond is reversible so propofol can be washed out from the plastic. Our data confirm earlier findings that accurate measurements of volatile propofol require exhaled air to be sampled as close as possible to the patient.