540 Chemie
Refine
Year of publication
- 2015 (6) (remove)
Document Type
- Journal article (5)
- Doctoral Thesis (1)
Language
- English (6)
Is part of the Bibliography
- yes (6)
Institute
- Life Sciences (6)
Publisher
- Royal Society of Chemistry (2)
- Wiley (2)
- American Chemical Society (1)
Foam has been employed as an improved or enhanced oil recovery method to overcome gravity override and the channeling and fingering of the injected gas, which arises because of the low density and viscosity of the injected fluid combined with the rock heterogeneity. A major challenge, however, is the stability of the generated foam when it contacts the oil. In this study we investigate the feasibility of using inexpensive nanoparticles made of coal fly ash, an abundantly available waste product of coal power plants, as a foam booster. We investigate the viability of reducing the size of fly ash particles to 100−200 nm using high-frequency ultrasonic grinding. We also study the foaminess (foamability), strength, and stability of the foams made with minor concentrations of fly ash nanoparticles and surfactant, both in bulk and porous media. The effect of monovalent and divalent ion concentration on the foaminess of the nanoash suspension combined with very low concentrations of a commercial alpha olefin sulfonate (AOS) surfactant, in the presence and absence of oil, is studied. We observe that bulk foam that contains very small amounts of nanoash particles shows a higher stability in the presence of model oils. Furthermore, experiments in porous media exhibit remarkably stronger foam with mixtures of nanoash and surfactant, such that the amount of produced liquids from the cores significantly increases. For the first time we show that nanoash can be used to stabilize nitrogen foam in the presence of crude oil at high temperature and pressure. In the presence of oil, the nanoash−AOS foam shows a higher stability, although crude oil tends to form stable emulsions in water in the presence of nanoash.
Unter der Zielsetzung der multimodalen, ortsaufgelösten optischen Spektroskopie für die markierungsfreie Charakterisierung biologischer Materialien nach Morphologie und Chemie werden vier Themenschwerpunkte behandelt.
1. Theorie der elastischen / inelastischen Lichtstreuung und laterale Auflösung in der Mikroskopie
2. Erweiterung eines Raman Mikroskops zu einem multimodalen spektralen Imaging System (MSIS) mit Photonenmigrations-Technologie
3. Erweiterung des MSIS zu Super-Resolution Raman Mikroskopie mit einer Festkörper-Immersionslinse
4. Anwendung des entwickelten MSIS auf biologische Materialien
Block-copolyesters of polyethylene terephthalate (PET) and polyethylene naphthalate (PEN) were synthesized via reactive extrusion. The influence of processing parameters on the material properties on a molecular scale like degree of trans-esterification, block length, and degree of randomness were investigated. The varied process factors were extrusion temperature and rotational speed. The effects of process parameter variation were investigated by 1H-NMR-spectroscopy. The experimental results show a clear dependence of the molecular properties on the processing conditions. By using statistical experimental design (DoE), it was possible to prepare defined copolyesters from PET and PEN without addition of further chemicals. With a degree of randomness between 0.05 and 0.5, the presence of an actual copolyester was confirmed when appropriate extrusion conditions were applied. The reactive extrusion process was confirmed to be suitable to produce defined block-copolyesters in a predictable and reproducible way. It was possible to produce designed sequence lengths, which could be adjusted within a range of 11–136 repeating units in the case of PET and, in the case of PEN, of 2.5–26. The produced materials can be used as barrier materials or barrier coatings to protect substrates against molecular oxygen and water vapour, e.g., in organic photovoltaic applications or food packaging. The described method is a one-pot alternative method to the previously described chemical recycling pathway.
The interfacial compatibility between polymers and nanoclay fillers as well as the thermostability of both components are important characteristics for processing them into polymer composites. While the polymer component is often grafted using common polymerization reactions, the nanoclay component is usually surface modified by surfactant treatment to improve compatibility. In the present study, the polymer ethylene vinyl alcohol and a nanoclay filler based on natural bentonite are both surface modified by different silanes, 3-glycidoxypropyltrimethoxysilane and methacryloxymethyltrimethoxysilane and their interfacial properties are investigated by inverse gas chromatography. The silane-modified samples had improved interfacial properties as reflected by a significant increase in dispersive and specific surface energies. Lewis acidities were determined using chloroform and 1,4-dioxane as polar probes and showed a good match between polymer and nanofiller interfaces. Lewis acidity was generally lower after silane-modification. Silanization yielded increased thermal stability of the treated samples. Thus, silanization led to improved compatibility and enhanced thermal stability which facilitates further processing.
Ion Mobility Spectrometry (IMS) is a widely used and `well-known’ technique of ion separation in the gaseous phase based on the differences in ion mobilities under an electric field. All IMS instruments operate with an electric field that provides space separation, but some IMS instruments also operate with a drift gas flow that provides also a temporal separation. In this review we will summarize the current IMS instrumentation. IMS techniques have received an increased interest as new instrumentation and have become available to be coupled with mass spectrometry (MS). For each of the eight types of IMS instruments reviewed it is mentioned whether they can be hyphenated with MS and whether they are commercially available. Finally, out of the described devices, the six most-consolidated ones are compared. The current review article is followed by a companion review article which details the IMS hyphenated techniques (mainly gas chromatography and mass spectrometry) and the factors that make the data from an IMS device change as a function of device parameters and sampling conditions. These reviews will provide the reader with an insightful view of the main characteristics and aspects of the IMS technique.
Ion Mobility Spectrometry (IMS) is a widely used and ‘well-known’ technique of ion separation in the gaseous phase based on the differences of ion mobilities under an electric field. This technique has received increased interest over the last several decades as evidenced by the pace and advances of new IMS devices available. In this review we explore the hyphenated techniques that are used with IMS, specifically mass spectrometry as an identification approach and a multi-capillary column as a pre-separation approach. Also, we will pay special attention to the key figures of merit of the ion mobility spectrum and how data sets are treated, and the influences of the experimental parameters on both conventional drift time IMS (DTIMS) and miniaturized IMS also known as high Field Asymmetric IMS (FAIMS) in the planar configuration. The present review article is preceded by a companion review article which details the current instrumentation and contains the sections that configure both conventional DTIMS and FAIMS devices. These reviews will give the reader an insightful view of the main characteristics and aspects of the IMS technique.