540 Chemie
Refine
Document Type
- Journal article (17)
- Doctoral Thesis (2)
- Book (1)
Has full text
- no (20) (remove)
Is part of the Bibliography
- yes (20)
Institute
- Life Sciences (18)
- Informatik (1)
- Texoversum (1)
Publisher
- Elsevier (6)
- Royal Society of Chemistry (6)
- The Royal Society of Chemistry (2)
- Gupta (1)
- IOP Publishing (1)
- Schweizerbart Science Publishers (1)
- Universität Tübingen (1)
- Wiley (1)
The properties of polyelectrolyte multilayers are ruled by the process parameters employed during self-assembly. This is the first study in which a design of experiment approach was used to validate and control the production of ultrathin polyelectrolyte multilayer coatings by identifying the ranges of critical process parameters (polyelectrolyte concentration, ionic strength and pH) within which coatings with reproducible properties (thickness, refractive index and hydrophilicity) are created. Mathematical models describing the combined impact of key process parameters on coatings properties were developed demonstrating that only ionic strength and pH affect the coatings thickness, but not polyelectrolyte concentration. While the electrolyte concentration had a linear effect, the pH contribution was described by a quadratic polynomial. A significant contribution of this study is the development of a new approach to estimate the thickness of polyelectrolyte multilayer nanofilms by quantitative rhodamine B staining, which might be useful in all cases when ellipsometry is not feasible due to the shape complexity or small size of the coated substrate. The novel approach proposed here overcomes the limitations of known methods as it offers a low spatial sampling size and the ability to analyse a wide area without restrictions on the chemical composition and shape of the substrate.
Herein the optimization of the physicochemical properties and surface biocompatibility of polyelectrolyte multilayers of the natural, biocompatible and biodegradable, linear polysaccharides hyaluronan and chitosan by Hofmeister anions was systematically investigated. We demonstrated that there is an interconnection between the bulk and surface properties of HA/Chi multilayers both varying in accordance with the arrangement of the anions in the Hofmeister series. Kosmotropic anions increased the hydration, thickness, micro- and macro-roughness, and hydrophilicity and improved the biocompatibility of the films by reduction (2 orders of magnitude) of the films stiffness and complete anti-thrombogenicity.
We report the temperature dependence of metal-enhanced fluorescence (MEF) of individual photosystem I (PSI) complexes from Thermosynechococcus elongatus (T. elongatus) coupled to gold nanoparticles (AuNPs). A strong temperature dependence of shape and intensity of the emission spectra is observed when PSI is coupled to AuNPs. For each temperature, the enhancement factor (EF) is calculated by comparing the intensity of individual AuNP-coupled PSI to the mean intensity of ‘uncoupled’ PSI. At cryogenic temperature (1.6 K) the average EF was 4.3-fold. Upon increasing the temperature to 250 K the EF increases to 84-fold. Single complexes show even higher EFs up to 441.0-fold. At increasing temperatures the different spectral pools of PSI from T. elongatus become distinguishable. These pools are affected differently by the plasmonic interactions and show different enhancements. The remarkable increase of the EFs is explained by a rate model including the temperature dependence of the fluorescence yield of PSI and the spectral overlap between absorption and emission spectra of AuNPs and PSI, respectively.
Unprecedented formation of sterically stabilized phospholipid liposomes of cuboidal morphology
(2021)
Sterically stabilized phospholipid liposomes of unprecedented cuboid morphology are formed upon introduction in the bilayer membrane of original polymers, based on polyglycidol bearing a lipid-mimetic residue. Strong hydrogen bonding in the polyglycidol sublayers creates attractive forces, which, facilitated by fluidization of the membrane, bring about the flattening of the bilayers and the formation of cuboid vesicles.
Here, we report the continuous peroxide-initiated grafting of vinyltrimethoxysilane (VTMS) onto a standard polyolefin by means of reactive extrusion to produce a functionalized liquid ethylene propylene copolymer (EPM). The effects of the process parameters governing the grafting reaction and their synergistic interactions are identified, quantified and used in a mathematical model of the extrusion process. As process variables the VTMS and peroxide concentrations and the extruder temperature setting were systematically studied for their influence on the grafting and the relative grafting degree using a face-centered central composite design (FCD). The grafting degree was quantified by 1H NMR spectroscopy. Response surface methodology (RSM) was used to calculate the most efficient grafting process in terms of chemical usage and graft yield. With the defined processing window, it was possible to make precise predictions about the grafting degree with at the same time highest possible relative degree of grafting.
Ion Mobility Spectrometry (IMS) is a widely used and `well-known’ technique of ion separation in the gaseous phase based on the differences in ion mobilities under an electric field. All IMS instruments operate with an electric field that provides space separation, but some IMS instruments also operate with a drift gas flow that provides also a temporal separation. In this review we will summarize the current IMS instrumentation. IMS techniques have received an increased interest as new instrumentation and have become available to be coupled with mass spectrometry (MS). For each of the eight types of IMS instruments reviewed it is mentioned whether they can be hyphenated with MS and whether they are commercially available. Finally, out of the described devices, the six most-consolidated ones are compared. The current review article is followed by a companion review article which details the IMS hyphenated techniques (mainly gas chromatography and mass spectrometry) and the factors that make the data from an IMS device change as a function of device parameters and sampling conditions. These reviews will provide the reader with an insightful view of the main characteristics and aspects of the IMS technique.
Ion Mobility Spectrometry (IMS) is a widely used and ‘well-known’ technique of ion separation in the gaseous phase based on the differences of ion mobilities under an electric field. This technique has received increased interest over the last several decades as evidenced by the pace and advances of new IMS devices available. In this review we explore the hyphenated techniques that are used with IMS, specifically mass spectrometry as an identification approach and a multi-capillary column as a pre-separation approach. Also, we will pay special attention to the key figures of merit of the ion mobility spectrum and how data sets are treated, and the influences of the experimental parameters on both conventional drift time IMS (DTIMS) and miniaturized IMS also known as high Field Asymmetric IMS (FAIMS) in the planar configuration. The present review article is preceded by a companion review article which details the current instrumentation and contains the sections that configure both conventional DTIMS and FAIMS devices. These reviews will give the reader an insightful view of the main characteristics and aspects of the IMS technique.
The transmembrane Ca2+ − activated Cl− channel - human bestrophin-1 (hBest1) is expressed in retinal pigment epithelium and mutations of BEST1 gene cause ocular degenerative diseases colectivelly referred to as “bestrophinopathies”. A large number of genetical, biochemical, biophysical and molecular biological studies have been performed to understand the relationship between structure and function of the hBest1 protein and its pathophysiological significance. Here, we review the current understanding of hBest1 surface organization, interactions with membrane lipids in model membranes, and its association with microdomains of cellular membranes. These highlights are significant for modulation of channel activity in cells.
Gegenstand dieser Arbeit ist die Darstellung und Charakterisierung einheitlicher, mesoporöser Silica-Partikel (MPSM) im Mikrometerbereich mit maßgeschneiderten Partikel- und Porendesign für die Hochleistungsflüssigkeitschromatographie. Die Synthese umfasst die Einlagerung von Silica-Nanopartikeln (SNP) in poröse organische Template, welche anschließend bei 600°C zersetzt werden. Die Impfsuspensionspolymerisation von Polystyrol-Partikeln, unter Verwendung von Glycidylmethacrylat, Ethylenglycoldimethacrylat und Porogenen, ermöglicht die Herstellung hochgradig einheitlicher, poröser p(GMA-co-EDMA)-Template. Der Einfluss wesentlicher Faktoren, einschließlich des Monomer-Porogen-Verhältnisses, des Monomerverhältnisses und der Porogenzusammensetzung, werden systematisch untersucht sowie ihre Auswirkungen auf die Porengröße, das Porenvolumen und die spezifische Oberfläche erläutert. Die Anbindung aminofunktionalisierter Substanzen erfolgt durch die Ringöffnung der Epoxidgruppe. Im anschließenden basischen Sol-Gel-Prozess werden die Silica-Nanopartikel aufgrund der Ladungsunterschiede in die funktionalisierten p(GMA-co-EDMA)-Template eingebaut. Die Partikelgröße der SNP beeinflusst wesentlich die Poreneigenschaften der MPSM und hängt von drei Faktoren ab: (i) der Wachstumsgeschwindigkeit in der kontinuierlichen Phase, die durch die Einstellungen des Sol-Gel-Prozesses gesteuert wird, (ii) der Diffusionsrate, die durch elektrostatische Anziehung reguliert wird und vom Grad der Funktionalisierung abhängt und (iii) der Porosität des Polymer-Templats. Die gezielte Anpassung der Poreneigenschaften durch die Prozesseinstellungen erlaubt die präzise Herstellung von MPSM, die auf spezifische Trennherausforderungen zugeschnitten werden und somit die Qualität der HPLC verbessern. Die vorgestellte Synthesestrategie ermöglicht, aufgrund des stufenweisen molekularen Aufbaus, eine bessere Adaption der stationären Phase an spezifische Trennherausforderungen.
High-performance liquid chromatography is one of the most important analytical tools for the identification and separation of substances. The efficiency of this method is largely determined by the stationary phase of the columns. Although monodisperse mesoporous silica microspheres (MPSM) represent a commonly used material as stationary phase their tailored preparation remains challenging. Here we report on the synthesis of four MPSMs via the hard template method. Silica nanoparticles (SNPs) which form the silica network of the final MPSMs were generated in situ from tetraethyl orthosilicate (TEOS) in the presence of (3-aminopropyl) triethoxysilane (APTES) functionalized p(GMA-co-EDMA) as hard template. Methanol, ethanol, 2-propanol, and 1-butanol were applied as solvents to control the size of the SNPs in the hybrid beads (HB). After calcination, MPSMs with different sizes, morphology and pore properties were obtained and characterized by scanning electron microscopy, nitrogen adsorption and desorption measurements, thermogravimetric analysis, solid state NMR and DRIFT IR spectroscopy. Interestingly, the 29Si NMR spectra of the HBs show T and Q group species which suggests that there is no covalent linkage between the SNPs and the template. The MPSMs were functionalized with trimethoxy (octadecyl) silane and used as stationary phases in reversed-phase chromatography to separate a mixture of eleven different amino acids. The separation characteristics of the MPSMs strongly depend on their morphology and pore properties which are controlled by the solvent during the preparation of the MPSMs. Overall, the separation behavior of the best phases is comparable with those of commercially available columns. The phases even achieve faster separation of the amino acids without loss of quality.