IGBT modules with anti-parallel FWDs are widely used in inductive load switching power applications, such as motor drive applications. Nowadays there is a continuous effort to increase the efficiency of such systems by decreasing their switching losses. This paper addresses the problems arising in the turn-on process of an IGBT working in hard-switching conditions. A method is proposed which achieves – contrary to most other approaches – a high switching speed and, at the same time, a low peak reverse-recovery current. This is done by applying an improved gate current waveform that is briefly lowered during the turn-on process. The proposed method achieves low switching losses. Its effectiveness is demonstrated by experimental results with IGBT modules for 600V and 1200V.
This paper addresses the turn-on switching process of insulated-gate bipolar transistor (IGBT) modules with anti-parallel free-wheeling diodes (FWD) used in inductive load switching power applications. An increase in efficiency, i.e. decrease in switching losses, calls for a fast switching process of the IGBT, but this commonly implies high values of the reverse-recovery current overshoot. To overcome this undesired behaviour, a solution was proposed which achieves an independent control of the collector current slope and peak reverse recovery current by applying a gate current that is briefly turned negative during the turn-on process. The feasibility of this approach has already been shown, however, a sophisticated control method is required for applying it in applications with varying currents, temperature and device parameters. In this paper a solution based on an adaptive, iterative closed-loop ontrol is proposed. Its effectiveness is demonstrated by experimental results from a 1200 V/200A IGBT power module for different load currents and reverse-recovery current overshoots.
An experimental study of a zero voltage switching SiC boost converter with an active snubber network
(2015)
This paper presents a quasi-resonant, zero voltage switching (ZVS) SiC boost converter for an output power of up to 10 kW. The converter is realized with an easily controllable active snubber network that allows a reduction of switching losses by minimizing the voltage stress applied to the active switch. With this approach, an increase of the switching frequency is possible, allowing a reduction of the system size. Experiments show a maximum converter efficiency up to 99.2% for a switching frequency of 100 kHz. A second version of the converter enables a further size reduction by increasing the switching frequency to 300 kHz while still reaching a high efficiency up to 98.4 %.
Nowadays robust, energy-efficient multisensor microsystems often come with heavily restricted power budgets and the characteristic of remaining in certain states for a longer period of time. During this time frame there is no continuous clock signal required which gives the opportunity to suspend the clock until a new transition is requested. In this paper, we present a new topology for on-demand locally clocked finite state machines. The architecture combines a local adaptive clocking approach with synchronous and asynchronous components forming a quasi synchronous system. Using adaptive and local clocking comes with the advantages of reducing the power consumption while saving design effort when no global clock tree is needed. Combining synchronous and asynchronous components is beneficial compared to previous fully asynchronous approaches concerning the design restrictions. The developed topology is verified by the implementation and simulation of a temperature-ADC sensor system realized in a 180 nm process.
The increase in distributed energy generation, such as photovoltaic systems (PV) or combined heat and power plants (CHP), poses new challenges to almost every distribution network operator (DNO). In the low-voltage (LV) grids, where installed PV capacity approaches the magnitude of household load, reverse power flow occurs at the secondary substa-tions. High PV penetration leads to voltage rise, flicker and loading problems. These problems have been addressed by the application of various techniques amongst which is the deployment of step voltage regulators (SVR). SVR can solve the voltage problem, but do not prevent or reduce reverse power flows. Therefore, the application of SVR in low voltage grids can result in significant power losses upstream. In this paper we present part of a research project investi-gating the application of remote-controlled cable cabinets (CC) with metering units in a low-voltage network as a possible alternative for SVR. A new generation of custom-made remote-control cable cabinets has been deployed and dynamic network reconfigurations (NR) have been realized with the following objectives: (i) reduction of reverse power flow through the secondary substation to the upstream network and therefore a reduction of upstream losses, (ii) reduction of the voltage rise caused by distributed energy resources and (iii) load balancing in the low-voltage grid. Secondary objec-tives are to improve the DNO's insight into the state of the network and to provide further information on future smart grid integration.
A novel gate driving approach to balance the transient current of parallel-connected GaN-HEMTs
(2018)
To enable higher current handling capability of GaN-based DC/DC converters, devices have to be used in parallel. However, their switching times differ, especially if their threshold voltages are not identical, which causes unbalanced device current. This paper focuses on the homogeneous distribution of turn-on switching losses of GaN-HEMTs connected in parallel. By applying a new gate driver concept, the transient current is distributed evenly. The effectiveness of this concept is demonstrated by double pulse measurements, for switching currents up to 45A and a voltage of 400V. A uniform current distribution is achieved, including a reduction of the turn-on losses by 50% compared to a conventional setup.
The increasing slew rate of modern power switches can increase the efficiency and reduce the size of power electronic applications. This requires a fast and robust signal transmission to the gate driver of the high-side switch. This work proposes a galvanically isolated capacitive signal transmission circuit to increase common mode transient immunity (CMTI). An additional signal path is introduced to significantly improve the transmission robustness for small duty cycles to assure a safe turn-off of the power switch. To limit the input voltage range at the comparator on the secondary side during fast high-side transitions, a clamping structure is implemented. A comparison between a conventional and the proposed signal transmission is performed using transistor level simulations. A propagation delay of about 2 ns over a wide range of voltage transients of up to 300V/ns at input voltages up to 600V is achieved.
The demonstration project Virtual Power Plant Neckar-Alb is constructing a Virtual Power Plant (VPP) demonstration site at the Reutlingen University campus. The VPP demonstrator integrates a heterogeneous set of distributed energy resources (DERs) which are connected to control the infrastructure and an energy management system. This paper describes the components and the architecture of the demonstrator and presents strategies for demonstration of multiple optimization and control systems with different control paradigms.
Class Phi2 amplifier using GaN HEMTs at 13.56MHz with tuned transformer for wireless power transfer
(2022)
This paper discusses a design procedure of a wireless power transfer system at a RF switching frequency of 13.56MHz. The wireless power transfer amplifier uses GaN HEMTs in aClass phi2 topology and is designed in order to achieve high efficiency and high power density. A design method for the load over a certain bandwidth is presented for a transformer with its tuning network.
DC-DC-converters are used in many different applications. Specifying the switching frequency is the most important parameter to calculate component costs and required space. Especially automotive applications of small brushed- or brushless dc-motors and the increasing number of DC-DC-converters have high requirements on the structual space (low box volume). This is of particular importance for automotive converters for the new 48 V board net. Multiplying the frequency by two will reduce the size of the power inductor by half at a given specification for output-voltage ripple. Smaller power inductors result in reduced losses due to smaller series resistance and parasitic capacitance. Furthermore a larger switching frequency decreases the size of the DC link capacitors. The circuit will get more idealized. However, as the switching losses increase with frequency, a DC-DC-converter can only benefit from these advantages if the switching behavior can be improved.
This paper presents an optimization method to increase switching slope and switching frequency of a 3.6 kW 3-phase step-up converter by separating the design and layout process into two parts. The first part is the power stage which carries the load current. It contains the power inductance and the drain-source-channel of the power MOSFETs. The second part is the driver circuit which contains the driver ICs, the gate resistor and the gate input impedance. While the switching slope was measured to be improved by 50 % , the switching time decreased by 20 %. Hence, the switching frequency of the step-up converter could be increased from 100 kHz to 200 kHz without loss increase. By mounting the driver ICs in a piggyback configuration in close proximity to the power stage, the parasitics could be further reduced significantly and 500 kHz switching frequency could be achieved with 97.5 % efficiency.