The increase in distributed energy generation, such as photovoltaic systems (PV) or combined heat and power plants (CHP), poses new challenges to almost every distribution network operator (DNO). In the low-voltage (LV) grids, where installed PV capacity approaches the magnitude of household load, reverse power flow occurs at the secondary substa-tions. High PV penetration leads to voltage rise, flicker and loading problems. These problems have been addressed by the application of various techniques amongst which is the deployment of step voltage regulators (SVR). SVR can solve the voltage problem, but do not prevent or reduce reverse power flows. Therefore, the application of SVR in low voltage grids can result in significant power losses upstream. In this paper we present part of a research project investi-gating the application of remote-controlled cable cabinets (CC) with metering units in a low-voltage network as a possible alternative for SVR. A new generation of custom-made remote-control cable cabinets has been deployed and dynamic network reconfigurations (NR) have been realized with the following objectives: (i) reduction of reverse power flow through the secondary substation to the upstream network and therefore a reduction of upstream losses, (ii) reduction of the voltage rise caused by distributed energy resources and (iii) load balancing in the low-voltage grid. Secondary objec-tives are to improve the DNO's insight into the state of the network and to provide further information on future smart grid integration.
Electronic design automation approaches can roughly be divided into optimizers and procedures. While the former have enabled highly automated synthesis flows for digital integrated circuits, the latter play a vital (but mostly underestimated role) in the analog domain. This paper describes both automation strategies in comparison, identifying two fundamentally different automation paradigms that reflect the two basic design practices known as “top-down” and “bottom-up”. Then, with a focus on the latter, the history of procedural approaches is traced from their
early beginnings until today’s evolvements and future prospects to underline their practical importance and to accentuate their scientific value, both in itself and in the overall context of EDA.
This paper presents a machine learning powered, procedural sizing methodology based on pre-computed look-up tables containing operating point characteristics of primitive devices. Several Neural Networks are trained for 90nm and 45nm technologies, mapping different electrical parameters to the corresponding dimensions of a primitive device. This transforms the geometric sizing problem into the domain of circuit design experts, where the desired electrical characteristics are now inputs to the model. Analog building blocks or entire circuits are expressed as a sequence of model evaluations, capturing the sizing strategy and intention of the designer in a procedure, which is reusable across different technology nodes. The methodology is employed for the sizing of two operational amplifiers, and evaluated for two technology nodes, showing the versatility and efficiency of this approach.
This paper presents an improvement in usability and integrity of simulation-based analog circuit sizing. Instead of using geometrical sizing parameters (width, length), a transformed design-space, consisting exclusively of electrical parameters (branch currents, efficiencies and speed) is utilized. This design-space is explored more efficiently by optimizers. Moreover, this design-space can be reduced without affecting the quality of the result. The method is illustrated on two application examples, a symmetrical and a miller operational amplifier. Sizing the circuits using the transformed design-space showed significant reduction in required circuit simulations (up to 11x faster), better convergence, without loss in quality.
The current paper proposes a design method for an active damping approach for LC output filters in a power stage for motor control with continuous output voltage. The power stage uses GaN-HEMTs and operates at switching frequencies in a range between 500 kHz and 1MHz. The active damping of the output filter is achieved here by a feedback of the filter inductor current using a high-pass structure. The paper discusses the impact of this feedback on the system behavior and proposes a design method.
Nowadays robust, energy-efficient multisensor microsystems often come with heavily restricted power budgets and the characteristic of remaining in certain states for a longer period of time. During this time frame there is no continuous clock signal required which gives the opportunity to suspend the clock until a new transition is requested. In this paper, we present a new topology for on-demand locally clocked finite state machines. The architecture combines a local adaptive clocking approach with synchronous and asynchronous components forming a quasi synchronous system. Using adaptive and local clocking comes with the advantages of reducing the power consumption while saving design effort when no global clock tree is needed. Combining synchronous and asynchronous components is beneficial compared to previous fully asynchronous approaches concerning the design restrictions. The developed topology is verified by the implementation and simulation of a temperature-ADC sensor system realized in a 180 nm process.
Usually battery chargers have two stages and DC charging current is considered to by necessary for a proper charging. To decrease the charger volume, a single stage LLC battery charger is investigated in this paper. PFC stage is eliminated, therefore no bulky capacitor is necessary any more, and battery is charged with a sinusoidal-like charging current. However, previous studies show that such a pulsating charging current has only minimal impact on battery life and efficiency. Design considerations of the resonant tank and optimal transformer design are presented. A 360W single stage LLC converter prototype for e-bike charger achieves a power factor of 0.98, efficiency of 0.93 and power density of 1,8kW/dm³.
The efficient production and utilization of green hydrogen is vital to succeed in the global strive for a sustainable future. To provide the necessary amount of green hydrogen a high number of electrolyzers will be connected as decentralized power consumers to the grid. A large amount of decentralized renewable power sources will provide the energy. In such a system a control method is necessary to dispatch the available power most efficiently. In particular, the shutdown of renewable energy sources due to temporary overproduction must be avoided. This paper presents a decentralized tertiary control algorithm that provides a new decentralized control approach, thus creating a flexible, robust and easily scalable system. The operation of each grid participant within this grid connected microgrid is optimized for maximum financial profit, while minimizing the exchange of power with the mains grid and reducing the shutdown of renewable power sources.
This paper describes a new method for condition monitoring of a roller chain. In contrast to conventional methods, no additional accelerometers are used to measure and interpret frequency spectra but the chain condition is evaluated using an easy to interpret similarity measure based on correlation functions using the driving motor torque. An additional clustering of current data and reference measurements yields an easy to understand representation of the chain condition.
The integration of renewable energy sources in single family homes is challenging. Advance knowledge of the demand of electrical energy, heat, and domestic hot water (DHW) is useful to schedule projectable devices like heat pumps. In this work, we consider demand time series for heat and DHW from 2018 for a single family home in Germany. We compare different forecasting methods to predict such demands for the next day. While the 1-day-back forecast method led to the prediction of heat demand, the N-day-average performed best for DHW demand when Unbiased Exponentially Moving Average (UEMA) is used with a memory of 2.5 days. This is surprising as these forecasting methods are very simple and do not leverage additional information sources such as weather forecasts.
Class Phi2 amplifier using GaN HEMTs at 13.56MHz with tuned transformer for wireless power transfer
(2022)
This paper discusses a design procedure of a wireless power transfer system at a RF switching frequency of 13.56MHz. The wireless power transfer amplifier uses GaN HEMTs in aClass phi2 topology and is designed in order to achieve high efficiency and high power density. A design method for the load over a certain bandwidth is presented for a transformer with its tuning network.
The increasing slew rate of modern power switches can increase the efficiency and reduce the size of power electronic applications. This requires a fast and robust signal transmission to the gate driver of the high-side switch. This work proposes a galvanically isolated capacitive signal transmission circuit to increase common mode transient immunity (CMTI). An additional signal path is introduced to significantly improve the transmission robustness for small duty cycles to assure a safe turn-off of the power switch. To limit the input voltage range at the comparator on the secondary side during fast high-side transitions, a clamping structure is implemented. A comparison between a conventional and the proposed signal transmission is performed using transistor level simulations. A propagation delay of about 2 ns over a wide range of voltage transients of up to 300V/ns at input voltages up to 600V is achieved.
Power loss measurement of power electronic components and overall systems is sometimes difficult by use of electrical quantities and in few applications even not possible. The calorimetric power loss measurement is an established method to identify the overall system losses with a suitable accuracy. This paper presents a novel method with an open chamber calorimeter under accurate air mass flow, air pressure, humidity measurement and temperature control. The benefits are the approximately halved measurement time compared to established systems and the possibility to control the chamber temperature. So it is possible to measure the power losses at different ambient temperatures.
Switched reluctance motors are particularly attractive due to their simple structure. The control of this machine type requires the instants, to switch the currents in the motor phases in an appropriate sequence. These switching instants are determined either based on a position sensor, or on signals generated by a sensorless method. A very simple sensorless method uses the switching frequency of the hysteresis controllers used for phase current control. This paper first presents an automatic commissioning method for this sensorless method and second a startup procedure, thus enhancing this approach towards an application in industry.
IGBT modules with anti-parallel FWDs are widely used in inductive load switching power applications, such as motor drive applications. Nowadays there is a continuous effort to increase the efficiency of such systems by decreasing their switching losses. This paper addresses the problems arising in the turn-on process of an IGBT working in hard-switching conditions. A method is proposed which achieves – contrary to most other approaches – a high switching speed and, at the same time, a low peak reverse-recovery current. This is done by applying an improved gate current waveform that is briefly lowered during the turn-on process. The proposed method achieves low switching losses. Its effectiveness is demonstrated by experimental results with IGBT modules for 600V and 1200V.
An experimental study of a zero voltage switching SiC boost converter with an active snubber network
(2015)
This paper presents a quasi-resonant, zero voltage switching (ZVS) SiC boost converter for an output power of up to 10 kW. The converter is realized with an easily controllable active snubber network that allows a reduction of switching losses by minimizing the voltage stress applied to the active switch. With this approach, an increase of the switching frequency is possible, allowing a reduction of the system size. Experiments show a maximum converter efficiency up to 99.2% for a switching frequency of 100 kHz. A second version of the converter enables a further size reduction by increasing the switching frequency to 300 kHz while still reaching a high efficiency up to 98.4 %.
This paper addresses the turn-on switching process of insulated-gate bipolar transistor (IGBT) modules with anti-parallel free-wheeling diodes (FWD) used in inductive load switching power applications. An increase in efficiency, i.e. decrease in switching losses, calls for a fast switching process of the IGBT, but this commonly implies high values of the reverse-recovery current overshoot. To overcome this undesired behaviour, a solution was proposed which achieves an independent control of the collector current slope and peak reverse recovery current by applying a gate current that is briefly turned negative during the turn-on process. The feasibility of this approach has already been shown, however, a sophisticated control method is required for applying it in applications with varying currents, temperature and device parameters. In this paper a solution based on an adaptive, iterative closed-loop ontrol is proposed. Its effectiveness is demonstrated by experimental results from a 1200 V/200A IGBT power module for different load currents and reverse-recovery current overshoots.
The demonstration project Virtual Power Plant Neckar-Alb is constructing a Virtual Power Plant (VPP) demonstration site at the Reutlingen University campus. The VPP demonstrator integrates a heterogeneous set of distributed energy resources (DERs) which are connected to control the infrastructure and an energy management system. This paper describes the components and the architecture of the demonstrator and presents strategies for demonstration of multiple optimization and control systems with different control paradigms.
A procedural approach to automate the manual design process in analog integrated circuit design
(2018)
This paper presents a novel approach to automating the design of analog integrated circuits: (1) the Expert Design Plan (EDP), a procedural generator, and (2) the EDP Language, a high-level description language for writing an EDP. An EDP is a parameterizable, executable script, which reproduces a designer’s course of action when designing a circuit. Thus, an EDP formalizes the design expert’s knowledge-based strategy and makes it reusable. Since it is essential that an EDP represents a circuit designers’ way of thinking and working as close as possible, the designers themselves should be enabled to create the EDP. Therefore, our approach provides a input method through a domain-specific language called EDP Language (EDPL). Using this language is intuitive and requires no special training. In an exemplary implementation of our approach, a common-source amplifier is automatically sized using a set of only 10 instructions. Even in the first usage our EDP approach has appeared to be more efficient than the manual sizing process.
A novel gate driving approach to balance the transient current of parallel-connected GaN-HEMTs
(2018)
To enable higher current handling capability of GaN-based DC/DC converters, devices have to be used in parallel. However, their switching times differ, especially if their threshold voltages are not identical, which causes unbalanced device current. This paper focuses on the homogeneous distribution of turn-on switching losses of GaN-HEMTs connected in parallel. By applying a new gate driver concept, the transient current is distributed evenly. The effectiveness of this concept is demonstrated by double pulse measurements, for switching currents up to 45A and a voltage of 400V. A uniform current distribution is achieved, including a reduction of the turn-on losses by 50% compared to a conventional setup.
DC-DC-converters are used in many different applications. Specifying the switching frequency is the most important parameter to calculate component costs and required space. Especially automotive applications of small brushed- or brushless dc-motors and the increasing number of DC-DC-converters have high requirements on the structual space (low box volume). This is of particular importance for automotive converters for the new 48 V board net. Multiplying the frequency by two will reduce the size of the power inductor by half at a given specification for output-voltage ripple. Smaller power inductors result in reduced losses due to smaller series resistance and parasitic capacitance. Furthermore a larger switching frequency decreases the size of the DC link capacitors. The circuit will get more idealized. However, as the switching losses increase with frequency, a DC-DC-converter can only benefit from these advantages if the switching behavior can be improved.
This paper presents an optimization method to increase switching slope and switching frequency of a 3.6 kW 3-phase step-up converter by separating the design and layout process into two parts. The first part is the power stage which carries the load current. It contains the power inductance and the drain-source-channel of the power MOSFETs. The second part is the driver circuit which contains the driver ICs, the gate resistor and the gate input impedance. While the switching slope was measured to be improved by 50 % , the switching time decreased by 20 %. Hence, the switching frequency of the step-up converter could be increased from 100 kHz to 200 kHz without loss increase. By mounting the driver ICs in a piggyback configuration in close proximity to the power stage, the parasitics could be further reduced significantly and 500 kHz switching frequency could be achieved with 97.5 % efficiency.