Refine
Document Type
- Journal article (27)
- Conference proceeding (25)
- Book chapter (1)
Language
- English (53) (remove)
Is part of the Bibliography
- yes (53)
Institute
- Informatik (53)
Publisher
- Springer (16)
- De Gruyter (11)
- SPIE. The International Society for Optical Engineering (5)
- IEEE (4)
- IOP Publishing (4)
- Deutsche Gesellschaft für Computer- und Roboterassistierte Chirurgie e.V. (2)
- Deutsche Gesellschaft für Computer- und Roboterassistierte Chirurgie e. V. (1)
- Elsevier (1)
- GMDS e.V. (1)
- Morressier (1)
An operating room is a stressful work environment. Nevertheless, all involved persons have to work safely as there is no space for mistakes. To ensure a high level of concentration and seamless interaction, all involved persons have to know their own tasks and the tasks of their colleagues. The entire team must work synchronously at all times. To optimize the overall workflow, a task manager supporting the team was developed. In parallel, a common conceptual design of a business process visualization was developed, which makes all relevant information accessible in real-time during a surgery. In this context an overview of all processes in the operating room was created and different concepts for the graphical representation of these user-dependent processes were developed. This paper describes the concept of the task manager as well as the general concept in the field of surgery.
An operation room is a stressful work environment. Nevertheless, all involved persons have to work safely as there is no space for making mistakes. To ensure a high level of concentration and seamless interaction, all involved persons have to know their own tasks and tasks of their colleagues. The entire team must work synchronously at all times. However, the operation room (OR) is a noisy environment and the actors have to set their focus on their work. To optimize the overall workflow, a task manager supporting the team was developed. Each actor is equipped with a client terminal showing a summary of their own tasks. Moreover, a big screen displays all tasks of all actors. The architecture is a distributed system based on a communication framework that supports the interaction of all clients with the task manager. A prototype of the task manager and several clients have been developed and implemented. The system represents a proof-of-concept for further development. This paper describes the concept of the task manager.
Clinical reading centers provide expertise for consistent, centralized analysis of medical data gathered in a distributed context. Accordingly, appropriate software solutions are required for the involved communication and data management processes. In this work, an analysis of general requirements and essential architectural and software design considerations for reading center information systems is provided. The identified patterns have been applied to the implementation of the reading center platform which is currently operated at the Center of Ophthalmology of the University Hospital of Tübingen.
Uncontrolled movements of laparoscopic instruments can lead to inadvertent injury of adjacent structures. The risk becomes evident when the dissecting instrument is located outside the field of view of the laparoscopic camera. Technical solutions to ensure patient safety are appreciated. The present work evaluated the feasibility of an automated binary classification of laparoscopic image data using Convolutional Neural Networks (CNN) to determine whether the dissecting instrument is located within the laparoscopic image section. A unique record of images was generated from six laparoscopic cholecystectomies in a surgical training environment to configure and train The CNN. By using a temporary version of the neural network, the annotation of the training image files could be automated and accelerated. A combination of oversampling and selective data augmentation was used to enlarge the fully labelled image data set and prevent loss of accuracy due to imbalanced class volumes. Subsequently the same approach was applied to the comprehensive, fully annotated Cholec80 database. The described process led to the generation of extensive and balanced training image data sets. The performance of the CNN-based binary classifiers was evaluated on separate test records from both databases. On our recorded data, an accuracy of 0.88 with regard to the safety-relevant classification was achieved. The subsequent evaluation on the Cholec80 data set yielded an accuracy of 0.84. The presented results demonstrate the feasibility of a binary classification of laparoscopic image data for the detection of adverse events in a surgical training environment using a specifically configured CNN architecture.
The focus of the developed maturity model was set on processes. The concept of the widespread CMM and its practices has been transferred to the perioperative domain and the concept of the new maturity model. Additional optimization goals and technological as well as networking-specific aspects enable a process- and object-focused view of the maturity model in order to ensure broad coverage of different subareas. The evaluation showed that the model is applicable to the perioperative field. Adjustments and extensions of the maturity model are future steps to improve the rating and classification of the new maturity model.
Recent advances in artificial intelligence have enabled promising applications in neurosurgery that can enhance patient outcomes and minimize risks. This paper presents a novel system that utilizes AI to aid neurosurgeons in precisely identifying and localizing brain tumors. The system was trained on a dataset of brain MRI scans and utilized deep learning algorithms for segmentation and classification. Evaluation of the system on a separate set of brain MRI scans demonstrated an average Dice similarity coefficient of 0.87. The system was also evaluated through a user experience test involving the Department of Neurosurgery at the University Hospital Ulm, with results showing significant improvements in accuracy, efficiency, and reduced cognitive load and stress levels. Additionally, the system has demonstrated adaptability to various surgical scenarios and provides personalized guidance to users. These findings indicate the potential for AI to enhance the quality of neurosurgical interventions and improve patient outcomes. Future work will explore integrating this system with robotic surgical tools for minimally invasive surgeries.
Glioblastomas are the most aggressive fast-growing primary brain cancer which originate in the glial cells of the brain. Accurate identification of the malignant brain tumor and its sub-regions is still one of the most challenging problems in medical image segmentation. The Brain Tumor Segmentation Challenge (BraTS) has been a popular benchmark for automatic brain glioblastomas segmentation algorithms since its initiation. In this year, BraTS 2021 challenge provides the largest multi-parametric (mpMRI) dataset of 2,000 pre-operative patients. In this paper, we propose a new aggregation of two deep learning frameworksnamely, DeepSeg and nnU-Net for automatic glioblastoma recognition in pre-operative mpMRI. Our ensemble method obtains Dice similarity scores of 92.00, 87.33, and 84.10 and Hausdorff Distances of 3.81, 8.91, and 16.02 for the enhancing tumor, tumor core, and whole tumor regions, respectively, on the BraTS 2021 validation set, ranking us among the top ten teams. These experimental findings provide evidence that it can be readily applied clinically and thereby aiding in the brain cancer prognosis, therapy planning, and therapy response monitoring. A docker image for reproducing our segmentation results is available online at (https://hub.docker.com/r/razeineldin/deepseg21).
Purpose
Artificial intelligence (AI), in particular deep neural networks, has achieved remarkable results for medical image analysis in several applications. Yet the lack of explainability of deep neural models is considered the principal restriction before applying these methods in clinical practice.
Methods
In this study, we propose a NeuroXAI framework for explainable AI of deep learning networks to increase the trust of medical experts. NeuroXAI implements seven state-of-the-art explanation methods providing visualization maps to help make deep learning models transparent.
Results
NeuroXAI has been applied to two applications of the most widely investigated problems in brain imaging analysis, i.e., image classification and segmentation using magnetic resonance (MR) modality. Visual attention maps of multiple XAI methods have been generated and compared for both applications. Another experiment demonstrated that NeuroXAI can provide information flow visualization on internal layers of a segmentation CNN.
Conclusion
Due to its open architecture, ease of implementation, and scalability to new XAI methods, NeuroXAI could be utilized to assist radiologists and medical professionals in the detection and diagnosis of brain tumors in the clinical routine of cancer patients. The code of NeuroXAI is publicly accessible at https://github.com/razeineldin/NeuroXAI.
Purpose
Artificial intelligence (AI), in particular deep learning (DL), has achieved remarkable results for medical image analysis in several applications. Yet the lack of human-like explanations of such systems is considered the principal restriction before utilizing these methods in clinical practice (Yang, Ye, & Xia, 2022).
Methods
Explainable Artificial Intelligence (XAI) provides a human-explainable and interpretable description of the “black-box” nature of DL (Gulum, Trombley, & Kantardzic, 2021). An effective XAI diagnosis generator, namely NeuroXAI (refer to Fig. 1), has been developed to extract 3D explanations from convolutional neural networks (CNN) models of brain gliomas (Zeineldin et al., 2022). By providing visual justification maps, NeuroXAI can help make DL models transparent and thus increase the trust of medical experts.
Results
NeuroXAI has been applied to two applications of the most widely investigated problems in brain imaging analysis, i.e. image classification and segmentation using magnetic resonance imaging (MRI). Visual attention maps of multiple XAI methods have been generated and compared for both applications, which could help to provide transparency about the performance of DL systems.
Conclusion
NeuroXAI helps to understand the prediction process of 3D CNN networks for brain glioma using human-understandable explanations. Results revealed that the investigated DL models behave in a logical human-like manner and can improve the analytical process of the MRI images systematically. Due to its open architecture, ease of implementation, and scalability to new XAI methods, NeuroXAI could be utilized to assist medical professionals in the detection and diagnosis of brain tumors. NeuroXAI code is publicly accessible at https://github.com/razeineldin/NeuroXAI
Access to clinical information during interventions is an important aspect to support the surgeon and his team in the OR. The OR-Pad research project aims at displaying clinically relevant information close to the patient during surgery. With the OR-Pad system, the surgeon shall be able to access case-specific information, displayed on a sterile-packaged, portable display device. Therefore, information shall be prepared before surgery and also be available afterwards. The project follows an user-centered design process. Within the third iteration, the interaction concept was finalized, resulting in an application that can be used in two modes, mobile and intraoperative, to support the surgeon before/after and during surgery, respectively. By supporting the surgeon perioperatively, it is expected to improve the information situation in the OR and thereby the quality of surgical results. Based on this concept, the system architecture was designed in detail, using a client-server architecture. Components, communication interfaces, exchanged data, and intended standards for data exchange of the OR-Pad system including connecting systems were conceived. Expert interviews by using a clickable prototype were conducted to evaluate the concepts.
The increasing heterogenecity of students at German Universities of Applied Sciences and the growing importance of digitization call for a rethinking of teaching and learning within higher education. In the next years, changing the learning ecosystem by developing and reflecting upon new teaching and learning techniques using methods of digitalization will be both - most relevant and very challenging. The following article introduces two different learning scenarios, which exemplify the implementation of new educational models that allow discontinuity of time and place, technology and process in teaching and learning. Within a blended learning apporach, the first learning scenario aims at adapting and individualizing the knowledge transfer in the course Foundations of Computer Science by providing knowledge individually and situation-specifically. The second learning scenario proposes a web-based tool to facilitate digital learning environments and thus digital learning communities and the possibility of computer-supported learning. The overall aim of both learning scenarios is to enhance learning for diverse groups by providing a different smart learning ecosystem in stepping away from a teacher-based to a student-centered approach. Both learning scenarios exemplarily represent the educational vision of Reutlingen University - its development into an interactive university.
Intra-operative fluoroscopy-guided assistance system for transcatheter aortic valve implantation
(2014)
A new surgical assistance system has been developed to assist the correct positioning of the AVP during transapical TAVI. The developed assistance system automatically defines the target area for implanting the AVP under live 2-D fluoroscopy guidance. Moreover, this surgical assistance system works with low levels of contrast agent for the final deployment of AVP, reducing therefore long-term negative effects, such as renal failure in the elderly and high-risk patients.
Accurate and safe neurosurgical intervention can be affected by intra-operative tissue deformation, known as brain-shift. In this study, we propose an automatic, fast, and accurate deformable method, called iRegNet, for registering pre-operative magnetic resonance images to intra-operative ultrasound volumes to compensate for brain-shift. iRegNet is a robust end-to-end deep learning approach for the non-linear registration of MRI-iUS images in the context of image-guided neurosurgery. Pre-operative MRI (as moving image) and iUS (as fixed image) are first appended to our convolutional neural network, after which a non-rigid transformation field is estimated. The MRI image is then transformed using the output displacement field to the iUS coordinate system. Extensive experiments have been conducted on two multi-location databases, which are the BITE and the RESECT. Quantitatively, iRegNet reduced the mean landmark errors from pre-registration value of (4.18 ± 1.84 and 5.35 ± 4.19 mm) to the lowest value of (1.47 ± 0.61 and 0.84 ± 0.16 mm) for the BITE and RESECT datasets, respectively. Additional qualitative validation of this study was conducted by two expert neurosurgeons through overlaying MRI-iUS pairs before and after the deformable registration. Experimental findings show that our proposed iRegNet is fast and achieves state-of-the-art accuracies outperforming state-of-the-art approaches. Furthermore, the proposed iRegNet can deliver competitive results, even in the case of non-trained images as proof of its generality and can therefore be valuable in intra-operative neurosurgical guidance.
The paper describes how eye-tracking can be used to explore electronic patient records (EPR) in a sterile environment. As an information display, we used a system that we developed for the presentation of patient data and for supporting surgical hand disinfection. The eye-tracking was performed using the Tobii Eye Tracker 4C, and the connection between the eye-tracker and the HTML website was realized using the Tobii EyeX Chrome Extension. Interactions with the EPR are triggered by fixations of icons. The interaction was working as intended, but test persons reported a high mental load while using the system.
Multi-dimensional patient data, such as time varying volume data, data of different imaging modalities, surface segmentations etc. are of growing importance in the clinical routine. For many use cases, it is of major importance to replicate a certain visualization of a data set created on one machine on a different computer using different software tools. Up until now, there exists no standardized methodology for this consistent presentation. We propose an extension of the Digital Imaging und Communications in Medicine (DICOM) called “Multi dimensional Presentation State” and outline scope and first results of the standardization process.
Automatic segmentation is essential for the brain tumor diagnosis, disease prognosis, and follow-up therapy of patients with gliomas. Still, accurate detection of gliomas and their sub-regions in multimodal MRI is very challenging due to the variety of scanners and imaging protocols. Over the last years, the BraTS Challenge has provided a large number of multi-institutional MRI scans as a benchmark for glioma segmentation algorithms. This paper describes our contribution to the BraTS 2022 Continuous Evaluation challenge. We propose a new ensemble of multiple deep learning frameworks namely, DeepSeg, nnU-Net, and DeepSCAN for automatic glioma boundaries detection in pre-operative MRI. It is worth noting that our ensemble models took first place in the final evaluation on the BraTS testing dataset with Dice scores of 0.9294, 0.8788, and 0.8803, and Hausdorf distance of 5.23, 13.54, and 12.05, for the whole tumor, tumor core, and enhancing tumor, respectively. Furthermore, the proposed ensemble method ranked first in the final ranking on another unseen test dataset, namely Sub-Saharan Africa dataset, achieving mean Dice scores of 0.9737, 0.9593, and 0.9022, and HD95 of 2.66, 1.72, 3.32 for the whole tumor, tumor core, and enhancing tumor, respectively.
This study is about estimating the reproducibility of finding palpation points of three different anatomical landmarks in the human body (Xiphoid Process and the 2 Hip Crests) to support a navigated ultrasound application. On 6 test subjects with different body mass index the three palpation points were located five times by two examiners. The deviation from the target position was calculated and correlated to the fat thickness above each palpation point. The reproducibility of the measurements had a mean error of ≈13.5 mm +- 4 mm, which seems to be sufficient for the desired application field.
Scheduled flexibility and individualization of knowledge transfer in foundations of computer science
(2017)
The opening of the German higher education system for new target groups involves a heterogeneous composition of students as never before and face up the universities to new challenges. Due to different educational biographies, the students don't show a homogeneous level of knowledge. Furthermore, their access to course content and their individual learning methods are very diverse. The existing lack of knowledge and the very unequal study speed have a significant influence on the learning behavior and learning motivation. During the first semesters, the dropout rate is appreciably higher. The reform project gives an overview of a didactic restructuring from a formerly conventional teaching and learning concept to a stronger combination of digital offers, combined with classical lectures in the basic modules of computer science. The teaching content is adjusted to the individual requirements and knowledge. Students with different previous knowledge get the possibility to increase their knowledge in different levels of abstraction. The aim of the reform project has to point out the possibilities, also the challenges of the digital process in higher education. At the same time the question has to be explored, how far does an accompanied and self-directed learning in own speed and in own individual depth of knowledge have a positive impact on the motivation and on the study success of a learner.
What might the attendee be able to do after being in your session?
Our work shows how to connect intra-operative devices via IEEE 11073 Service-oriented Device Connectivity (SDC).
Description of the Problem or Gap
Standardized device communication is essential for interoperability, availability of device data, and therefore for the intelligent operating room (OR) and arising solutions. The SDC standard was developed to make information from medical devices available in a uniform manner and enable interoperability. Existing devices are rarely SDC-capable and need interfaces to be interoperable via SDC.
Methods: What did you do to address the problem or gap?
We conceived an SDC-based architecture consisting of a service provider and service consumer. In our concept, the service provider is connected to the medical device and capable to translate the proprietary protocol of the device into SDC and vice versa. The service consumer is used to request or send information via the SDC protocol to the service provider and can function as a uniform bidirectional interface (e.g. for displaying or controlling). This concept was exemplarily demonstrated with the patient monitor MX800 of Philips to retrieve the device data (e.g. vital parameters) via SDC and partly for the operating light marLED X of KLS Martin Group.
Results: What was the outcome(s) of what you did to address the problem or gap?
The patient monitor MX800 was connected to a Raspberry Pi (RPi) via LAN, on which the service provider is running. The python script on the RPi establishes a connection to the monitor and translates incoming and outgoing messages from the proprietary protocol to SDC and vice versa to/from the service consumer. The service consumer is running on a laptop and acts as a simulation for different kinds of systems that want to get vital parameters or other information from the patient monitor. The operating light marLED X was connected to an RPi via USB-to-RS232. A python script on the RPi establishes a connection to the light and makes it possible via proprietary commands to get information of the light (e.g. status) and to control it (e.g. toggle the light, increment the intensity). A translation to SDC is not integrated yet.
Discussion of Results
Our practical implementation shows that medical devices can be accessed via external connections to get device data and control the device via commands. The example SDC implementation of the patient monitor MX800 makes it possible to request its data via the standardized communication protocol SDC. This is also possible for the operating light marLED X if its proprietary protocol is analyzed to be translatable to/from SDC. This would allow to control the device from an external system, or automatically depending on the status of the ongoing procedure. The advantage is, that existing intra-operative devices can be extended by a service provider which is capable of translating the proprietary protocol of the device in SDC and vice versa. This enables interoperability and an intelligent OR that, for example, is aware of all devices, their status, and data and can use this information to optimally support the surgeons and their team (e.g. provision of information, automated documentation). This interoperability allows that future innovations merely need to understand the SDC protocol instead of all vendor-dependent communication protocols.
Conclusion
Standardized device communication is essential to reach interoperability, and therefore intelligent ORs. Our contribution addresses the possibility of subsequently making medical devices SDC-capable. This may eliminate the need of understanding all the different proprietary protocols when developing new innovative solutions for the OR.
Motivation: Aim of this project is the automatic classification of total hip endoprosthesis (THEP) components in 2D Xray images. Revision surgeries of total hip arthroplasty (THA) are common procedures in orthopedics and trauma surgery. Currently, around 400.000 procedures per year are performed in the United States (US) alone. To achieve the best possible result, preoperative planning is crucial. Especially if parts of the current THEP system are to be retained.
Methods: First, a ground truth based on 76 X-ray images was created: We used an image processing pipeline consisting of a segmentation step performed by a convolutional neural network and a classification step performed by a support vector machine (SVM). In total, 11 classes (5 pans and 6 shafts) shall be classified.
Results: The ground truth generated was of good quality even though the initial segmentation was performed by technicians. The best segmentation results were achieved using a U-net architecture. For classification, SVM architectures performed much better than additional neural networks.
Conclusions: The overall image processing pipeline performed well, but the ground truth needs to be extended to include a broader variability of implant types and more examples per training class.