Exogenous factors of influence on exhaled breath analysis by ion-mobility spectrometry (MCC/IMS)
(2019)
The interpretation of exhaled breath analysis needs to address to the influence of exogenous factors, especially to a transfer of confounding analytes by the test persons. A test person who was exposed to a disinfectant had exhaled breath analysis by MCC/IMS (Bioscout®) after different time intervals. Additionally, a new sampling method with inhalation of synthetic air before breath analysis was tested. After exposure to the disinfectant, 3-Pentanone monomer, 3-Pentanone dimer, Hexanal, 3-Pentanone trimer, 2-Propanamine, 1-Propanol, Benzene, Nonanal showed significantly higher intensities, in exhaled breath and air of the examination room, compared to the corresponding baseline measurements. Only one ingredient of the disinfectant (1-Propanol) was identical to the 8 analytes. Prolonging the time intervals between exposure and breath analysis showed a decrease of their intensities. However, the half-time of the decrease was different. The inhalation of synthetic air - more than consequently airing the examination room with fresh air - reduced the exogenous and also relevant endogenous analytes, leading to a reduction and even changing polarity of the alveolar gradient. The interpretation of exhaled breath needs further knowledge about the former residence of the proband and the likelihood and relevance of the inhalation of local, site-specific and confounding exogenous analytes by him. Their inhalation facilitates a transfer to the examination room and a detection of high concentrations in room air and exhaled breath, but also the exhalation of new analytes. This may lead to a misinterpretation of these analytes as endogenous resp. disease-specific ones.
Standardisation of breath sampling is important for application of breath analysis in clinical settings. By studying the effect of room airing on indoor and breath analytes and by generating time series of room air with different sampling intervals we sought to get further insights into room air metabolism, to detect the relevance of exogenous VOCs and to make conclusions about their consideration for the interpretation of exhaled breath. Room air and exhaled breath of a healthy subject were analysed before and after room airing. Furthermore a time series of room air with doors and windows closed was taken over 84 h by an automatic sampling every 180 min. A second times series studied room air analytes over 70 h with samples taken every 16.5 min. For breath and room air measurements an IMS coupled to a multi-capillary column (IMS/MCC) [Bio-Scout® - B&S Analytik GmbH, Dortmund, Germany] was used. The peaks were characterized using the Software Visual Now (B&S Analytik, Dortmund Germany) and identified using the software package MIMA (version 1.1, provided by the Max Planck Institute for Informatics, Saarbrücken, Germany) and the database 20160426_SubstanzDbNIST_122 (B & S Analytik GmbH, Dortmund, Germany). In the morning 4 analytes (Decamethylcylopentasiloxane [541-02-6]; Pentan-2-one [107-87-9] – Dimer; Hexan-1-al [66-25-1]; Pentan-2-one [107-87-9]) – Monomer showed high intensities in the room air and exhaled breath. They were significantly but not equally reduced by room airing. The time series about 84 h showed a time dependent decrease of analytes (limonen-monomer and -dimer; Decamethylcylopentasiloxane, Butan-1-ol, Butan-1-ol) as well as increase (Pentan-2-one [107-87-9] – Dimer). Shorter sampling intervals exhibited circadian variations of analyte concentrations for many analytes. Breath sampling in the morning needs room airing before starting. Then the variation of the intensity of indoor analytes can be kept small. The time series of indoor analytes show, that their intensities have a different behaviour, with time dependent declines, constant increases and circadian variations, dependent on room airing. This has implications on the breath sampling procedure and the intrepretation of exhaled breath.
The isothermal curing of melamine resin is investigated by in-line infrared spectroscopy at different temperatures. The infrared spectra are decomposed into time courses of characteristic spectral patterns using Multivariate Curve Resolution (MCR). It was found that depending on the applied curing temperature, melamine films with different spectral fingerprints and correspondingly different chemical network structures are formed. The network structures of fully cured resin films are specific for the applied curing temperatures used and cannot simply be compensated by changes in the curing time. For industrial curing processes, this means that cure temperature is the main system determining factor at constant M:F ratio. However, different MF resin networks can be specifically obtained from one and the same melamine resin by suitable selection of the curing time and temperatures profiles to design resin functionality. The spectral fingerprints after short curing time as well as after long curing time reflect the fundamental differences in the thermoset networks that can be obtained with industrial short-cycle and multi-daylight presses.
Characterization of brain tumours requires neuropathological expertise and is generally performed by histological evaluation and molecular analysis. One emerging technique to assist pathologists in future tumour diagnostics is multimodal optical spectroscopy. In the current clinical routine, tissue preprocessing with formalin is widely established and suitable for spectroscopic investigations since degradation processes impede the measurement of native tissue. However, formalin fixation results in alterations of the tissue chemistry and morphology for example by protein cross-linking. As optical spectroscopy is sensitive to these variations, we evaluate the effects of formalin fixation on multimodal brain tumour data in this proof-of-concept study. Nonfixed and formalin-fixed cross sections of different common human brain tumours were subjected to analysis of chemical variations using ultraviolet and Fourier-transform infrared microspectroscopy. Morphological changes were assessed by elastic light scattering microspectroscopy in the visible wavelength range. Data were analysed with multivariate data analysis and compared with histopathology. Tissue type classifications deduced by optical spectroscopy are highly comparable and independent from the preparation and the fixation protocol. However, formalin fixation leads to slightly better classification models due to improved stability of the tissue. As a consequence, spectroscopic methods represent an appropriate additional contrast for chemical and morphological information in neuropathological diagnosis and should be investigated to a greater extent. Furthermore, they can be included in the clinical workflow even after formalin fixation.
This book describes the current state of the art in integrated ring resonators, covering more than two decades in the development of this exciting device. It discusses in depth one of the most fascinating and versatile integrated optical filters, providing readers with a panoramic view spanning from design and simulation to implementation in various material systems. Written by authors with extensive experience in both academia and industry, this second edition offers a much-needed, major update as interest in integrated ring resonators undergoes a global revival. The new edition includes a comprehensive technological update, and a timely discussion of recent advances in new application areas, such as optofluidics and microfluidics, telecom operations and biosensors. This aptly named compendium is the ideal guide for researchers and engineers looking to review the field as a whole while exploring several of its possible and exciting future trajectories.
Film formation of self synthesized Polymer EPM–g–VTMDS (ethylene–propylene rubber, EPM, grafted with vinyltetramethyldisiloxane, VTMDS) was studied regarding bonding to adhesion promoter vinyltrimethoxysilane (VTMS) on oxidized 18/10 chromium/nickel–steel (V2A) stainless steel surfaces. Polymer films of different mixed solutions including commercial siloxane and silicone, dimethyl, vinyl group terminated crosslinker (HANSA SFA 42100, CAS# 68083-19-2, 0.35 mmol Vinyl/g) and platinum, 1,3-diethenyl-1,1,3,3-tetramethyldisiloxane complex Karstedt's catalyst (ALPA–KAT 1, CAS# 68478-92-2) were spin coated on V2A stainless steel surfaces with adsorbed VTMS thin layers in order to analyze film formation of EPM–g–VTMDS at early stages. Surface topography and chemical bonding of the high performance polymers on different oxidized V2A surfaces were investigated with X–ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), scanning electron microscopy (SEM) and surface enhanced Raman spectroscopy (SERS). AFM and SEM as well as XPS results indicated that the formation of the polymer film proceeds via growth of polymer islands. Chemical signatures of the essential polymer contributions, linker and polymer backbones, could be identified using XPS core level peak shape analysis and also SERS. The appearance of signals which are related to Si–O–Si can be seen as a clear indication of lateral crosslinking and silica network formation in the films on the V2A surface.
Scanning Near-Field Optical Microscopy (SNOM) has developed during recent decades into a valuable tool to optically image the surface topology of materials with super-resolution. With aperture-based SNOM systems, the resolution scales with the size of the aperture, but also limits the sensitivity of the detection and thus the application for spectroscopic techniques like Raman SNOM. In this paper we report the extension of solid immersion lens (SIL) technology to Raman SNOM. The hemispherical SIL with a tip on the bottom acts as an apertureless dielectric nanoprobe for simultaneously acquiring topographic and spectroscopic information. The SIL is placed between the sample and the microscope objective of a confocal Raman microscope. The lateral resolution in the Raman mode is validated with a cross section of a semiconductor layer system and, at approximately 180 nm, is beyond the classical diffraction limit of Abbe.
The development of new materials that mimic cartilage and its function is an unmet need that will allow replacing the damaged parts of the joints, instead of the whole joint. Polyvinyl alcohol (PVA) hydrogels have raised special interest for this application due to their biocompatibility, high swelling capacity and chemical stability. In this work, the effect of post-processing treatments (annealing, high hydrostatic pressure (HHP) and gamma-radiation) on the performance of PVA gels obtained by cast-drying was investigated and, their ability to be used as delivery vehicles of the anti-inflammatories diclofenac or ketorolac was evaluated. HHP damaged the hydrogels, breaking some bonds in the polymeric matrix, and therefore led to poor mechanical and tribological properties. The remaining treatments, in general, improved the performance of the materials, increasing their crystallinity. Annealing at 150 °C generated the best mechanical and tribological results: higher resistance to compressive and tensile loads, lower friction coefficients and ability to support higher loads in sliding movement. This material was loaded with the anti-inflammatories, both without and with vitamin E (Vit.E) or Vit.E + cetalkonium chloride (CKC). Vit.E + CKC helped to control the release of the drugs which occurred in 24 h. The material did not induce irritability or cytotoxicity and, therefore, shows high potential to be used in cartilage replacement with a therapeutic effect in the immediate postoperative period.
Comparative analysis of the chemical and rheological curing kinetics of formaldehyde-based wood adhesives is crucial for assessing their respective performance. Differential scanning calorimetry (DSC) and rheometry are the conventional techniques used for monitoring the curing processes leading to crosslinking polymerization of the adhesives. However, the direct comparison of these techniques is inappropriate due to the intrinsic differences in their underlying procedures. To address this challenge, the two adhesive samples were sequentially cured, firstly with rheometry and followed by DSC. The observed higher curing degree in the subsequent DSC procedure underpins the incomplete curing of the samples during initial rheometry. Furthermore, the comparative assessment of the activation energies, molar ratios, and active groups of the two adhesives highlights the importance of the pre-exponential factor in addition to the activation energies, as it attributes to the probability of active groups coinciding at the appropriate spatial arrangement.
A lens-based Raman spectrometer is characterized by studying the optical elements in the optical path and we study the measure of aberration–diffraction effects. This is achieved by measuring the spectral resolution (SR) thus encompassing almost all optical elements of a spectrometer that are mostly responsible for such effects. An equation for SR is used to determine the quality factor Q which measures aberration/diffraction effects occurring in a spectrometer. We show how the quality factor changes with different spectrometer parameters such as grating groove density, the wavelength of excitation, pinhole width, charge-coupled device (CCD) pixel density, etc. This work provides an insight into the quality of a spectrometer and helps to monitor the performance of the spectrometer over a certain period. Commercially available spectrometers or home-built spectrometers are prone to misalignment in optical elements and can benefit from this work that allows maintaining the overall quality of the setup. Performing such experiments over a period helps to minimize the aberration/ diffraction effects occurring as a result of time and maintaining the quality of measurements.