610 Medizin, Gesundheit
Refine
Year of publication
- 2019 (4) (remove)
Document Type
- Journal article (4)
Language
- English (4)
Is part of the Bibliography
- yes (4)
Institute
- Life Sciences (4) (remove)
Publisher
- De Gruyter (1)
- Elsevier (1)
- IIAR (1)
- Lippincott Williams & Wilkins (1)
Size and function of bioartificial tissue models are still limited due to the lack of blood vessels and dynamic perfusion for nutrient supply. In this study, we evaluated the use of cytocompatible methacryl-modified gelatin for the fabrication of a hydrogel-based tube by dip-coating and subsequent photo-initiated cross-linking. The wall thickness of the tubes and the diameter were tuned by the degree of gelatin methacryl-modification and the number of dipping cycles. The dipping temperature of the gelatin solution was adjusted to achieve low viscous fluids of approximately 0.1 Pa s and was different for gelatin derivatives with different modification degrees. A versatile perfusion bioreactor for the supply of surrounding tissue models was developed, which can be adaped to several geometries and sizes of blood-vessel mimicking tubes. The manufactured bendable gelatin tubes were permeable for water and dissolved substances, like Nile Blue and serum albumin. As a proof of concept, human fibroblasts in a three-dimensional collagen tissue model were sucessfully supplied with nutrients via the central gelatin tube under dynamic conditions for 2 days. Moreover, the tubes could be used as scaffolds to build-up a functional and viable endothelial layer. Hence, the presented tools can contribute to solving current challenges in tissue engineering.
Background/Aim: The aim of this study was the development of a new osteoconductivity index to determine the bone healing capacities of bone substitute materials (BSM) on the basis of 3D microcomputed tomographic (μ-CT) data. Materials and Methods: Sinus biopsies were used for the comparative analysis of the integration behavior of two xenogeneic BSM (cerabone® and Bio Oss®). 3D μ-CT and data sets from histomorphometrical measurements based on 2D histological slices were used to measure the bone-material-contact and the tissue distribution within the biopsies. The tissue reactions to both BSM were microscopically analyzed. Results: The 3D and 2D results of the osteoconductivity measurements showed comparable material-bone contacts for both BSM, but the 2D data were significantly lower. The same results were found when tissue distribution was measured in both groups. The histopathological analysis showed comparative tissue reactions in both BSM. Conclusion: Osteoconductivity index is a reliable measurement parameter for determining the healing capacities of BSM. The observed differences between both measurement methods could be assigned to the resolution capacity of μ-CT data that did not allow for a precise interface distinction between both BSM and bone tissue. Histomorphometrical data based on histological slides still allow for a more exact evaluation.
New approaches to respiratory assist: bioengineering an ambulatory, miniaturized bioartificial lung
(2019)
Although state-of-the-art treatments of respiratory failure clearly have made some progress in terms of survival in patients suffering from severe respiratory system disorders, such as acute respiratory distress syndrome (ARDS), they failed to significantly improve the quality of life in patients with acute or chronic lung failure, including severe acute exacerbations of chronic obstructive pulmonary disease or ARDS as well. Limitations of standard treatment modalities, which largely rely on conventional mechanical ventilation, emphasize the urgent, unmet clinical need for developing novel(bio)artificial respiratory assist devices that provide extracorporeal gas exchange with a focus on direct extracorporeal CO2 removal from the blood. In this review, we discuss some of the novel concepts and critical prerequisites for such respiratory lung assist devices that can be used with an adequate safety profile, in the intensive care setting, as well as for long-term domiciliary therapy in patients with chronic ventilatory failure. Specifically, we describe some of the pivotal steps, such as device miniaturization, passivation of the blood-contacting surfaces by chemical surface modifications, or endothelial cell seeding, all of which are required for converting current lung assist devices into ambulatory lung assist device for long-term use in critically ill patients. Finally, we also discuss some of the risks and challenges for the long-term use of ambulatory miniaturized bioartificial lungs.
Today, virtualizing pharma R&D is increasingly related with data analytics and artificial intelligence (AI), technologies that have been developed by software companies outside the healthcare sector. The process of virtualizing pharma R&D is closely related to the technological advancements that result in the generation of large data sets ranging from genomics, proteomics, metabolomics, medical imaging, IoT wearables and large clinical trials, making it necessary for pharma companies to find new ways to store and ultimately analyze information. As a consequence, pharma companies are experimenting with AI in R&D ranging from in-silico drug design to clinical trail participants identification or dosage error reduction.