The analysis of exhaled metabolites has become a promising field of research in recent decades. Several volatile organic compounds reflecting metabolic disturbance and nutrition status have even been reported. These are particularly important for long-term measurements, as needed in medical research for detection of disease progression and therapeutic efficacy. In this context, it has become urgent to investigate the effect of fasting and glucose treatment for breath analysis. In the present study, we used amodel of ventilated rats that fasted for 12 h prior to the experiment. Ten rats per group were randomly assigned for continuous intravenous infusion without glucose or an infusion including 25 mg glucose per 100 g per hour during an observation period of 12 h. Exhaled gas was analysed using multicapillary column ion-mobility spectrometry. Analytes were identified by the BS-MCC/IMS database (version 1209; B & S Analytik, Dortmund, Germany). Glucose infusion led to a significant increase in blood glucose levels (p<0.05 at 4 h and thereafter) and cardiac output (p<0.05 at 4 h and thereafter). During the observation period, 39 peaks were found collectively. There were significant differences between groups in the concentration of ten volatile organic compounds: p<0.001 at 4 h and thereafter for isoprene, cyclohexanone, acetone, p-cymol, 2-hexanone, phenylacetylene, and one unknown compound, and p<0.001 at 8 h and thereafter for 1-pentanol, 1-propanol, and 2-heptanol. Our results indicate that for long-term measurement, fasting and the withholding of glucose could contribute to changes of volatile metabolites in exhaled air.
In breath analysis, ambient air contaminations are ubiquitous and difficult to eliminate. This study was designed to investigate the reduction of ambient air background by a lung wash-out with synthetic air. The reduction of the initial ambient air volatile organic compound (VOC) intensity was investigated in the breath of 20 volunteers inhaling synthetic air via a sealed full face mask in comparison to inhaling ambient air. Over a period of 30 minutes, breath analysis was conducted using ion mobility spectrometry coupled to a multi-capillary column. A total of 68 VOCs were identified for inhaling ambient air or inhaling synthetic air. By treatment with synthetic air, 39 VOCs decreased in intensity, whereas 29 increased in comparison to inhaling ambient air. In total, seven VOCs were significantly reduced (P-value < 0.05). A complete wash-out of VOCs in this setting was not observed, whereby a statistically significant reduction up to 65% as for terpinolene was achieved. Our setting successfully demonstrated a reduction of ambient air contaminations from the airways by a lung wash-out with synthetic air.
Ion mobility spectrometry coupled to multi capillary columns (MCC/IMS) combines highly sensitive spectrometry with a rapid separation technique. MCC\IMS is widely used for biomedical breath analysis. The identification of molecules in such a complex sample necessitates a reference database. The existing IMS reference databases are still in their infancy and do not allow to actually identify all analytes. With a gas chromatograph coupled to a mass selective detector (GC/MSD) setup in parallel to a MCC/IMS instrumentation we may increase the accuracy of automatic analyte identification. To overcome the time-consuming manual evaluation and comparison of the results of both devices, we developed a software tool MIMA (MS-IMS-Mapper), which can computationally generate analyte layers for MCC/IMS spectra by using the corresponding GC/MSD data. We demonstrate the power of our method by successfully identifying the analytes of a seven-component mixture. In conclusion, the main contribution of MIMA is a fast and easy computational method for assigning analyte names to yet un-assigned signals in MCC/IMS data. We believe that this will greatly impact modern MCC/IMS-based biomarker research by 'giving a name' to previously detected disease-specific molecules.
Rats are commonly used in medical research as they enable a high grade of standardization. The exhalome of ventilated rats has not as yet been investigated using an ion mobility spectrometer coupled with a multi-capillary column (MCC-IMS). As a first step, a rat model has to be established to measure potential biomarkers in the exhale with long-term settings, allowing constant and continuous analysis of exhaled air in time series. Therefore, eight animals were anaesthetized, prepared and ventilated for 1 h. A total of 73 peaks were directly detected with the IMS chromatogram. Thirty five of them were assigned to the ventilator system and 38 to the animals. Peak intensity varied within three measurements. The intensity of analytes of individual rats varied by a factor of up to 18. This new model will also enable continuous measurements of volatile organic compounds (VOCs) from rat's breath in long-term experiments. It is hoped that, in the future, variability and progression of VOCs can be monitored in different models of diseases using this set-up.
Online measurement of drug concentrations in patient's breath is a promising approach for individualized dosage. A direct transfer from breath- to blood-concentrations is not possible. Measured exhaled concentrations are following the blood-concentration with a delay in non-steady-state situations. Therefore, it is necessary to integrate the breath-concentration into a pharmacological model. Two different approaches for pharmacokinetic modelling are presented. Usually a 3-compartment model is used for pharmacokinetic calculations of blood concentrations. This 3-compartment model is extended with a 2-compartment model based on the first compartment of the 3-compartment model and a new lung compartment. The second approach is to calculate a time delay of changes in the concentration of the first compartment to describe the lung-concentration. Exemplarily both approaches are used for modelling of exhaled propofol. Based on time series of exhaled propofol measurements using an ion-mobility-spectrometer every minute for 346 min a correlation of calculated plasma and the breath concentration was used for modelling to deliver R2 = 0.99 interdependencies. Including the time delay modelling approach the new compartment coefficient ke0lung was calculated to ke0lung = 0.27 min−1 with R2 = 0.96. The described models are not limited to propofol. They could be used for any kind of drugs, which are measurable in patient's breath.
Background: Conventional methods for lung cancer detection including computed tomography (CT) and bronchoscopy are expensive and invasive. Thus, there is still a need for an optimal lung cancer detection technique. Methods: The exhaled breath of 50 patients with lung cancer histologically proven by bronchoscopic biopsy samples (32 adenocarcinomas, 10 squamous cell carcinomas, 8 small cell carcinomas), were analyzed using ion mobility spectrometry (IMS) and compared with 39 healthy volunteers. As a secondary assessment, we compared adenocarcinoma patients with and without epidermal growth factor receptor (EGFR) mutation. Results: A decision tree algorithm could separate patients with lung cancer including adenocarcinoma, squamous cell carcinoma and small cell carcinoma. One hundred-fifteen separated volatile organic compound (VOC) peaks were analyzed. Peak-2 noted as n-Dodecane using the IMS database was able to separate values with a sensitivity of 70.0% and a specificity of 89.7%. Incorporating a decision tree algorithm starting with n-Dodecane, a sensitivity of 76% and specificity of 100% was achieved. Comparing VOC peaks between adenocarcinoma and healthy subjects, n-Dodecane was able to separate values with a sensitivity of 81.3% and a specificity of 89.7%. Fourteen patients positive for EGFR mutation displayed a significantly higher n-Dodecane than for the 14 patients negative for EGFR (p<0.01), with a sensitivity of 85.7% and a specificity of 78.6%. Conclusion: In this prospective study, VOC peak patterns using a decision tree algorithm were useful in the detection of lung cancer. Moreover, n-Dodecane analysis from adenocarcinoma patients might be useful to discriminate the EGFR mutation.
Children undergoing systemic chemotherapy often suffer from severe immunosuppression usually associated to severe neutropenia (neutrophils < 0.5 x 109/l). Clinical courses during those periods range from asymptomatic to septic general conditions. Development of septic symptoms can be very fast and life-threatening. Swift detection of risk factors in those patients is therefore needed. So far no early, rapid and reliable marker or tool exists. Ion-Mobility-Spectrometry coupled with a Multi-Capillary-Column (IMS-MCC) can analyze more than 600 volatile components from exhaled air within a few minutes and hence is a potential, rapid detection-tool. As a proof of concept we measured the exhaled breath of 11 patients with neutropenia and 10 healthy controls ranging from 3 to 18 years of age at the time of measurement. Ten milliliters breath samples were taken at the outpatient clinic and analyzed with an onsite IMS-MCC (BreathDiscovery, B&S Analytik, Dortmund, Germany). Dead-space-volume was adapted to two groups (small 250 ml, large 500 ml). Interestingly 59 differing peaks were measured. Eleven were significantly different (p ≤ 0.05), three of which highly significant (p ≤ 0.01) in Mann-Whitney-Rank-Sum-testing. The corresponding analytes used in the decision tree are 2-Propanol, D-Limonene and Acetone. The analytes with the lowest rank sum identified are 2-Hexanone, Iso-Propylamine and 1-Butanol. Eventually we were able to show a three-step-decision-tree, which discerns the 21 samples except one from each group. Sensitivity was 90 % and specificity was 91 %. Naturally these findings need further confirmation within a bigger population. Our pilot-study proves that Ion-Mobility-Spectrometry coupled with a Multi-Capillary-Column is a feasible rapid diagnostic tool in the setting of a pediatric oncology out-patient clinic for patients 3 years and older. Our first results furthermore encourage additional analysis as to whether patients at risk for septic events during immunosuppression can be diagnosed in advance by rapidly assessing risk factors such as Neutropenia in exhaled breath.
The number of publications in the field of breath analysis using different types of ion mobility spectrometers (IMS) has increased over the last few years. In this paper, the publications between 2010 and 2013 are reviewed with respect to different types of IMS such as differential mobility spectrometers, high-field asymmetric waveform ion mobility spectrometers and multi-capillary columns coupled to conventional IMS. The analytes detected by IMS and declared with significance to a specific medical question were considered further with respect to medical and analytical questions. In total, 42 different analytes were found to be detected using IMS on a high significance level and were compared to findings using other analytical methods with respect to the individual analyte.
Background: Multicapillary column ion-mobility spectrometry (MCC-IMS) may identify volatile components in exhaled gas. The authors therefore used MCC-IMS to evaluate exhaled gas in a rat model of sepsis, inflammation, and hemorrhagic shock.
Methods: Male Sprague-Dawley rats were anesthetized and ventilated via tracheostomy for 10 h or until death. Sepsis was induced by cecal ligation and incision in 10 rats; a sham operation was performed in 10 others. In 10 other rats, endotoxemia was induced by intravenous administration of 10 mg/kg lipopolysaccharide. In a final 10 rats, hemorrhagic shock was induced to a mean arterial pressure of 35 +/- 5 mmHg. Exhaled gas was analyzed with MCC-IMS, and volatile compounds were identified using the BS-MCC/IMS-analytes database (Version 1209; B&S Analytik, Dortmund, Germany).
Results: All sham animals survived the observation period, whereas mean survival time was 7.9 h in the septic animals, 9.1 h in endotoxemic animals, and 2.5 h in hemorrhagic shock. Volatile compounds showed statistically significant differences in septic and endotoxemic rats compared with sham rats for 3-pentanone and acetone. Endotoxic rats differed significantly from sham for 1-propanol, butanal, acetophenone, 1,2-butandiol, and 2-hexanone. Statistically significant differences were observed between septic and endotoxemic rats for butanal, 3-pentanone, and 2-hexanone. 2-Hexanone differed from all other groups in the rats with shock.
Conclusions: Breath analysis of expired organic compounds differed significantly in septic, inflammation, and sham rats. MCC-IMS of exhaled breath deserves additional study as a noninvasive approach for distinguishing sepsis from inflammation.
Several diseases occur due to asbestos exposure. Until today, asbestos predicted mortality and morbidity will increase because of the long latency period. Actually, the methods to investigate asbestos related disease are mostly invasive. Therefore, the aim of the present paper was to investigate, whether signals in human breath could be correlated to Asbestos related lung diseases using a multi-capillary column (MCC) connected to an ion mobility spectrometer (IMS) as non-invasive method. Here, the breath samples of 10 mL of 25 patients suffering from asbestos related diseases. This group includes patients with asbestos related pleural thickening with and without pulmonary fibrosis. Twelve healthy persons constitute the control group and the breath samples are compared with those of the BK4103 patients. In total 83 peaks are found in the IMS-Chromatogram. A discrimination was possible with p-values <0.001 for two peaks (99.9 %), <0.01 (99 %) for 5 peaks and <0.05 (95 %) for 17 peaks. The most discrimination peaks alpha pinene and 4-ethyltoluol were identified among some others with lower p-values. The corresponding Box-and-Whisker-Plots comparing both groups are presented. In addition, a decision tree including all peaks was created that shows a differentiation with alpha pinene between BK4103 (pleural plaques group) and the control group. In addition, the sensitivity was calculated to 96 %, specificity was 50 %, positive and negative predictive values were 80 % and 86 %. Ion mobility spectrometry was introduced as non-invasive method to separate both groups Asbestos related and healthy. Naturally, the findings need further confirmation on larger population groups, but encourage further investigations, too.