This paper covers test and verification of a forecast-based Monte Carlo algorithm for an optimized, demand-oriented operation of combined heat and power (CHP) units using the hardware-in-the-loop approach. For this purpose, the optimization algorithm was implemented at a test bench at Reutlingen University for controlling a CHP unit in combination with a thermal energy storage, both in real hardware. In detail, the hardware-in-the-loop tests are intended to reveal the effects of demand forecasting accuracy, the impact of thermal energy storage capacity and the influence of load profiles on demand-oriented operation of CHP units. In addition, the paper focuses on the evaluation of the content of energy in the thermal energy storage under practical conditions. It is shown that a 5-layer model allows to determine the energy stored quite accurately, which is verified by experimental results. The hardware-in-the-loop tests disclose that demand forecasting accuracies, especially electricity demand forecasting, as well as load profiles strongly impact the potential for CHP electricity utilization on-site in demand-oriented mode. Moreover, it is shown that a larger effective capacity of the thermal energy storage positively affects demand-oriented operation. In the hardware-in-the-loop tests, the fraction of electricity generated by the CHP unit utilized on-site could thus be increased by a maximum of 27% compared to heat-led operation, which is still the most common modus operandi of small-scale CHP plants. Hence, the hardware-in-the-loop tests were adequate to prove the significant impact of the proposed algorithm for optimization of demand-oriented operation of CHP units.
On-chip metallization, especially in modern integrated BCD technologies, is often subject to high current densities and pronounced temperature cycles due to heat dissipation from power switches like LDMOS transistors. This paper continues the work on a sensor concept where small sense lines are embedded in the metallization layers above the active area of a switching LDMOS transistor. The sensors show a significant resistance change that correlates with the number of power cycles. Furthermore, influences of sense line layer, geometry and the dissipated energy are shown. In this paper, the focus lies on a more detailed analysis of the observed change in sense line resistance.
LDMOS transistors in integrated power technologies are often subject to thermo-mechanical stress, which degrades the on-chip metallization and eventually leads to a short. This paper investigates small sense lines embedded in the LDMOS metallization. It will be shown that their resistance depends strongly on the stress cycle number. Thus, they can be used as aging sensors and predict impending failures. Different test structures have been investigated to identify promising layout configurations. Such sensors are key components for resilient systems that adaptively reduce stress to allow aggressive LDMOS scaling without increasing the risk of failure.
The paper illustrates the status quo of a research project for the development of a control system enabling CHP units for a demand-oriented electricity production by an intelligent management of the heat storage tank. Thereby the focus of the project is twofold. One is the compensation of the fluctuating power production by the renewable energies solar and wind. Secondly, a reduction of the load on the power grid is intended by a better match of local electricity demand and production. In detail, the general control strategy is outlined, the method utilized for forecasting heat and electricity demand is illustrated as well as a correlation method for the temperature distribution in the heat storage tank based on a Sigmoid function is proposed. Moreover, the simulation model for verification and optimization of the control system and the two field test sites for implementing and testing the system are introduced.
Modern power DMOS transistors greatly benefit from the continuous advances of the technology, which yield devices with very low area-specific RDS,on figures of merit and therefore allow for significantly reduced active areas. However, in many applications, where the devices must dissipate high amounts of energy and thus are subjected to significant self-heating, the active area is not dictated by RDS,on requirements, but by the energy constraints. In this paper, a simple method of improving the energy capability and reliability of power DMOS transistors operating in pulsed conditions is proposed and experimentally verified. The method consists in redistributing the power density from the hotter to the cooler device regions, hence achieving a more homogeneous temperature distribution and a reduced peak temperature. To demonstrate the principle, a simple gate offset circuit is used to redistribute the current density to the cooler DMOS parts. No technology changes are needed for the implementation, only minor changes to the driver circuit are necessary, with a minimal impact on the additional required active area. Improvements in the energy capability from 9.2% up to 39% have been measured. Furthermore, measurements have shown that the method remains effective also if the operating conditions change significantly. The simplicity and the effectiveness of the implementation makes the proposed method suitable to be used in a wide range of applications.
Since November 2011 the standard DIN 4709 stipulates performance tests for Micro-CHP units in Germany. In contrast to steady state measurements of the CHP unit itself, the test according to DIN 4709 includes the thermal storage tank as well as the internal control unit, and it is based on a 24 h test cycle following a specified thermal load profile. Hence, heat losses from the storage tank are as well taken into account as transient losses of the CHP unit. In addition, the control strategy for loading and unloading the storage tank affects the test results.
The DIN 4709 test cycle has been applied at the test stand for Micro-CHP units at Reutlingen University, and results for the Micro-CHP unit WhisperGen and the EC Power units XRGI 15® and XRGI 20® are available. During the analysis a method has been developed to evaluate the results in case the test cycle does not end in a time slot between 24 and 24.5 h after the starting as demanded by DIN 4709. Since this method has been successfully applied to the test of various CHP units of different size and technology so far, it is suggested to incorporate it to DIN 4709 during the next revision of the standard.
The performance numbers obtained reveal the differences in efficiencies measured at steady-state on the one hand and following the DIN 4709 test cycle on the other hand. While the deviations in electrical efficiencies are small, thermal efficiencies according to DIN 4709 fall below steady state data by 3–6 percentage points. This is attributed to transient thermal losses and heat losses from the storage tank, which are not included in steady state and separate testing of the CHP unit, only.
In visual adaptive tracking, the tracker adapts to the target, background, and conditions of the image sequence. Each update introduces some error, so the tracker might drift away from the target over time. To increase the robustness against the drifting problem, we present three ideas on top of a particle filter framework: An optical-flow-based motion estimation, a learning strategy for preventing bad updates while staying adaptive, and a sliding window detector for failure detection and finding the best training examples. We experimentally evaluate the ideas using the BoBoT dataseta. The code of our tracker is available online.