004 Informatik
Refine
Document Type
- Journal article (23)
- Conference proceeding (20)
- Book chapter (1)
Is part of the Bibliography
- yes (44)
Institute
- Informatik (44)
- Technik (1)
Publisher
Software scripts for sensor data extraction in Rasberry Pi: user-space and kernel-space comparison
(2024)
This paper compares two popular scripting implementations for hardware prototyping: Python scripts execut from User-Space and C-based Linux-Driver processes executed from Kernel-Space, which can provide information to researchers when considering one or another in their implementations. Conclusions exhibit that deploying software scripts in the kernel space makes it possible to grant a certain quality of sensor information using a Raspberry Pi without the need for advanced real-time operational systems.
The development of automatic solutions for the detection of physiological events of interest is booming. Improvements in the collection and storage of large amounts of healthcare data allow access to these data faster and more efficiently. This fact means that the development of artificial intelligence models for the detection and monitoring of a large number of pathologies is becoming increasingly common in the medical field. In particular, developing deep learning models for detecting obstructive apnea (OSA) events is at the forefront. Numerous scientific studies focus on the architecture of the models and the results that these models can provide in terms of OSA classification and Apnea-Hypopnea-Index (AHI) calculation. However, little focus is put on other aspects of great relevance that are crucial for the training and performance of the models. Among these aspects can be found the set of physiological signals used and the preprocessing tasks prior to model training. This paper covers the essential requirements that must be considered before training the deep learning model for obstructive sleep apnea detection, in addition to covering solutions that currently exist in the scientific literature by analyzing the preprocessing tasks prior to training.
Development of an expert system to overpass citizens technological barriers on smart home and living
(2023)
Adopting new technologies can be overwhelming, even for people with experience in the field. For the general public, learning about new implementations, releases, brands, and enhancements can cause them to lose interest. There is a clear need to create point sources and platforms that provide helpful information about the novel and smart technologies, assisting users, technicians, and providers with products and technologies. The purpose of these platforms is twofold, as they can gather and share information on interests common to manufacturers and vendors. This paper presents the ”Finde-Dein-SmartHome” tool. Developed in association with the Smart Home & Living competence center [5] to help users learn about, understand, and purchase available technologies that meet their home automation needs. This tool aims to lower the usability barrier and guide potential customers to clear their doubts about privacy and pricing. Communities can use the information provided by this tool to identify market trends that could eventually lower costs for providers and incentivize access to innovative home technologies and devices supporting long-term care.
The influence of sleep on human health is enormous. Accordingly, sleep disorders can have a negative impact on it. To avoid this, they should be identified and treated in time. For this purpose, objective (with an appropriate device) or subjective (based on perceived values) measurement methods are used for sleep analysis to understand the problem. The aim of this work is to find out whether an exchange of the two methods is possible and can provide reliable results. In accordance with this goal, a study was conducted with people aged over 65 years old (a total of 154 night-time recordings) in which both measurement methods were compared. Sleep questionnaires and electronic devices for sleep assessment placed under the mattress were applied to achieve the study aims. The obtained results indicated that the correlation between both measurement methods could be observed for sleep characteristics such as total sleep time, total time in bed and sleep efficiency. However, there are also significant differences in absolute values of the two measurement approaches for some subjects/nights, which leads us to conclude that the substitution is more likely to be considered in case of long-term monitoring where the trends are of more importance and not the absolute values for individual nights.
Healthy sleep is one of the prerequisites for a good human body and brain condition, including general well-being. Unfortunately, there are several sleep disorders that can negatively affect this. One of the most common is sleep apnoea, in which breathing is impaired. Studies have shown that this disorder often remains undiagnosed. To avoid this, developing a system that can be widely used in a home environment to detect apnoea and monitor the changes once therapy has been initiated is essential. The conceptualisation of such a system is the main aim of this research. After a thorough analysis of the available literature and state of the art in this area of knowledge, a concept of the system was created, which includes the following main components: data acquisition (including two parts), storage of the data, apnoea detection algorithm, user and device management, data visualisation. The modules are interchangeable, and interfaces have been defined for data transfer, most of which operate using the MQTT protocol. System diagrams and detailed component descriptions, including signal requirements and visualisation mockups, have also been developed. The system's design includes the necessary concepts for the implementation and can be realised in a prototype in the next phase.
Sleep is an essential part of human existence, as we are in this state for approximately a third of our lives. Sleep disorders are common conditions that can affect many aspects of life. Sleep disorders are diagnosed in special laboratories with a polysomnography system, a costly procedure requiring much effort for the patient. Several systems have been proposed to address this situation, including performing the examination and analysis at the patient's home, using sensors to detect physiological signals automatically analysed by algorithms. This work aims to evaluate the use of a contactless respiratory recording system based on an accelerometer sensor in sleep apnea detection. For this purpose, an installation mounted under the bed mattress records the oscillations caused by the chest movements during the breathing process. The presented processing algorithm performs filtering of the obtained signals and determines the apnea events presence. The performance of the developed system and algorithm of apnea event detection (average values of accuracy, specificity and sensitivity are 94.6%, 95.3%, and 93.7% respectively) confirms the suitability of the proposed method and system for further ambulatory and in-home use.
Monitoring heart rate and breathing is essential in understanding the physiological processes for sleep analysis. Polysomnography (PSG) system have traditionally been used for sleep monitoring, but alternative methods can help to make sleep monitoring more portable in someone's home. This study conducted a series of experiments to investigate the use of pressure sensors placed under the bed as an alternative to PSG for monitoring heart rate and breathing during sleep. The following sets of experiments involved the addition of small rubber domes - transparent and black - that were glued to the pressure sensor. The resulting data were compared with the PSG system to determine the accuracy of the pressure sensor readings. The study found that the pressure sensor provided reliable data for extracting heart rate and respiration rate, with mean absolute errors (MAE) of 2.32 and 3.24 for respiration and heart rate, respectively. However, the addition of small rubber hemispheres did not significantly improve the accuracy of the readings, with MAEs of 2.3 bpm and 7.56 breaths per minute for respiration rate and heart rate, respectively. The findings of this study suggest that pressure sensors placed under the bed may serve as a viable alternative to traditional PSG systems for monitoring heart rate and breathing during sleep. These sensors provide a more comfortable and non-invasive method of sleep monitoring. However, the addition of small rubber domes did not significantly enhance the accuracy of the readings, indicating that it may not be a worthwhile addition to the pressure sensor system.
The importance of sleep for human life is enormous. It affects physical, mental, and psychological health. Therefore, it is vital to recognise sleep disorders in a timely manner in order to be able to initiate therapy. There are two methods for measuring sleep-related parameters - objective and subjective. Whether the substitution of a subjective method for an objective one is possible is investigated in this paper. Such replacement may bring several advantages, including increased comfort for the user. To answer this research question, a study was conducted in which 75 overnight recordings were evaluated. The primary purpose of this study was to compare both ways of measurement for total sleep time and sleep efficiency, which are essential parameters for, e.g., insomnia diagnosis and treatment. The evaluation results demonstrated that, on average, there are 32 minutes of difference between the two measurement methods when total sleep time is analysed. In contrast, on average, both measurement methods differ by 7.5% for sleep efficiency measurement. It should also be noted that people typically overestimate total sleep time and efficiency with the subjective method, where the perceived values are measured.
Sleep is essential to existence, much like air, water, and food, as we spend nearly one-third of our time sleeping. Poor sleep quality or disturbed sleep causes daytime solemnity, which worsens daytime activities' mental and physical qualities and raises the risk of accidents. With advancements in sensor and communication technology, sleep monitoring is moving out of specialized clinics and into our everyday homes. It is possible to extract data from traditional overnight polysomnographic recordings using more basic tools and straightforward techniques. Ballistocardiogram is an unobtrusive, non-invasive, simple, and low-cost technique for measuring cardiorespiratory parameters. In this work, we present a sensor board interface to facilitate the communication between force sensitive resistor sensor and an embedded system to provide a high-performing prototype with an efficient signal-to-noise ratio. We have utilized a multi-physical-layer approach to locate each layer on top of another, yet supporting a low-cost, compact design with easy deployment under the bed frame.
Today many scientific works are using deep learning algorithms and time series, which can detect physiological events of interest. In sleep medicine, this is particularly relevant in detecting sleep apnea, specifically in detecting obstructive sleep apnea events. Deep learning algorithms with different architectures are used to achieve decent results in accuracy, sensitivity, etc. Although there are models that can reliably determine apnea and hypopnea events, another essential aspect to consider is the explainability of these models, i.e., why a model makes a particular decision. Another critical factor is how these deep learning models determine how severe obstructive sleep apnea is in patients based on the apnea-hypopnea index (AHI). Deep learning models trained by two approaches for AHI determination are exposed in this work. Approaches vary depending on the data format the models are fed: full-time series and window-based time series.