Informatik
Refine
Document Type
- Journal article (44) (remove)
Language
- English (44)
Is part of the Bibliography
- yes (44)
Institute
- Informatik (44)
Publisher
- Elsevier (44) (remove)
The development of automatic solutions for the detection of physiological events of interest is booming. Improvements in the collection and storage of large amounts of healthcare data allow access to these data faster and more efficiently. This fact means that the development of artificial intelligence models for the detection and monitoring of a large number of pathologies is becoming increasingly common in the medical field. In particular, developing deep learning models for detecting obstructive apnea (OSA) events is at the forefront. Numerous scientific studies focus on the architecture of the models and the results that these models can provide in terms of OSA classification and Apnea-Hypopnea-Index (AHI) calculation. However, little focus is put on other aspects of great relevance that are crucial for the training and performance of the models. Among these aspects can be found the set of physiological signals used and the preprocessing tasks prior to model training. This paper covers the essential requirements that must be considered before training the deep learning model for obstructive sleep apnea detection, in addition to covering solutions that currently exist in the scientific literature by analyzing the preprocessing tasks prior to training.
During the first years of the last decade, Egypt used to face recurrent electricity cut-offs in summer. In the past few years, the electricity tariff dramatically increased. Radiative cooling to the clear night sky is a renewable energy source that represents a relative solution. The dry desert climate promotes nocturnal radiative cooling applications. This study investigates the potential of nocturnal radiative cooling systems (RCSs) to reduce the energy consumption of the residential building sector in Egypt. The system technology proposed in this work is based on uncovered solar thermal collectors integrated into the building hydronic system. By implementing different control strategies, the same system could be used for both cooling and heating applications. The goal of this paper is to analyze the performance of RCSs in residential buildings in Egypt. The dynamic simulation program TRNSYS was used to simulate the thermal behavior of the system. The relevant issues of Egypt as a case-study are firstly overviewed. Then the paper introduces the work done to develop a building model that represents a typical residential apartment in Egypt. Typical occupancy profiles were developed to define the internal thermal gains. The adopted control strategy to optimize the system operation is presented as well. To fully understand and hence evaluate the operation of the proposed RCS, four simulation cases were considered: 1. a reference case (fully passive), 2. the stand-alone operation of the RCS, 3. ideal heating & cooling operation (fully-active), and 4. the hybrid-operation (when the active cooling system is supported by the proposed RCS). The analysis considered the main three distinct climates in Egypt, represented by the cities of Alexandria, Cairo and Asyut. The hotter and drier weather conditions resulted in a higher cooling potential and larger temperature differences. The simulated cooling power in Asyut was 28.4 W/m² for a 70 m² absorber field. For a smaller field area of 10 m², the cooling power reached 109 W/m² but with humble temperature differences. To meet the rigorous thermal comfort conditions, the proposed sensible RCS cannot fully replace conventional air-conditioning units, especially in humid areas like Alexandria. When working in a hybrid system, a 10% reduction in the active cooling energy demand could be achieved in Asyut to keep the cooling set-point at 24 °C. This percentage reduction was nearly doubled when the thermal comfort set-point was increased by two degrees (26 °C). In a sensitivity analysis, external shading devices as a passive measure as well as the implementation of the Egyptian code for buildings (ECP306/1–2005) were also investigated. The analysis of this study raised other relevant aspects to discuss, e.g. system-sizing, environmental effects, limitations and recommendations.
Background and purpose: Transapical aortic valve replacement (TAVR) is a recent minimally invasive surgical treatment technique for elderly and high-risk patients with severe aortic stenosis. In this paper,a simple and accurate image-based method is introduced to aid the intra-operative guidance of TAVR procedure under 2-D X-ray fluoroscopy.
Methods: The proposed method fuses a 3-D aortic mesh model and anatomical valve landmarks with live 2-D fluoroscopic images. The 3-D aortic mesh model and landmarks are reconstructed from interventional X-ray C-arm CT system, and a target area for valve implantation is automatically estimated using these aortic mesh models.Based on template-based tracking approach, the overlay of visualized 3-D aortic mesh model, land-marks and target area of implantation is updated onto fluoroscopic images by approximating the aortic root motion from a pigtail catheter motion without contrast agent. Also, a rigid intensity-based registration algorithm is used to track continuously the aortic root motion in the presence of contrast agent.Furthermore, a sensorless tracking of the aortic valve prosthesis is provided to guide the physician to perform the appropriate placement of prosthesis into the estimated target area of implantation.
Results: Retrospective experiments were carried out on fifteen patient datasets from the clinical routine of the TAVR. The maximum displacement errors were less than 2.0 mm for both the dynamic overlay of aortic mesh models and image-based tracking of the prosthesis, and within the clinically accepted ranges. Moreover, high success rates of the proposed method were obtained above 91.0% for all tested patient datasets.
Conclusion: The results showed that the proposed method for computer-aided TAVR is potentially a helpful tool for physicians by automatically defining the accurate placement position of the prosthesis during the surgical procedure.
Cardiovascular diseases are directly or indirectly responsible for up to 38.5% of all deaths in Germany and thus represent the most frequent cause of death. At present, heart diseases are mainly discovered by chance during routine visits to the doctor or when acute symptoms occur. However, there is no practical method to proactively detect diseases or abnormalities of the heart in the daily environment and to take preventive measures for the person concerned. Long-term ECG devices, as currently used by physicians, are simply too expensive, impractical, and not widely available for everyday use. This work aims to develop an ECG device suitable for everyday use that can be worn directly on the body. For this purpose, an already existing hardware platform will be analyzed, and the corresponding potential for improvement will be identified. A precise picture of the existing data quality is obtained by metrological examination, and corresponding requirements are defined. Based on these identified optimization potentials, a new ECG device is developed. The revised ECG device is characterized by a high integration density and combines all components directly on one board except the battery and the ECG electrodes. The compact design allows the device to be attached directly to the chest. An integrated microcontroller allows digital signal processing without the need for an additional computer. Central features of the evaluation are a peak detection for detecting R-peaks and a calculation of the current heart rate based on the RR interval. To ensure the validity of the detected R-peaks, a model of the anatomical conditions is used. Thus, unrealistic RR-intervals can be excluded. The wireless interface allows continuous transmission of the calculated heart rate. Following the development of hardware and software, the results are verified, and appropriate conclusions about the data quality are drawn. As a result, a very compact and wearable ECG device with different wireless technologies, data storage, and evaluation of RR intervals was developed. Some tests yelled runtimes up to 24 hours with wireless Lan activated and streaming.