Informatik
Refine
Year of publication
- 2023 (70) (remove)
Document Type
- Conference proceeding (34)
- Journal article (29)
- Book chapter (4)
- Doctoral Thesis (3)
Has full text
- yes (70) (remove)
Is part of the Bibliography
- yes (70)
Institute
- Informatik (70)
Publisher
- Springer (17)
- Elsevier (9)
- IEEE (8)
- MDPI (5)
- Association for Computing Machinery (3)
- Academic Conferences International (2)
- Emerald (2)
- Hochschule Reutlingen (2)
- IARIA (2)
- IOP Publishing (2)
This paper presents the first part of a research-work conducted at the University of Applied Sciences (HFT- Stuttgart). The aim of the research was to investigate the potential of low-cost renewable energy systems to reduce the energy demand of the building sector in hot and dry areas. Radiative cooling to the night sky represents a low-cost renewable energy source. The dry desert climate conditions promote radiative cooling applications. The system technology adopted in this work is based on uncovered solar thermal collectors integrated into the building’s hydronic system. By implementing different control strategies, the same system could be used for cooling as well as for heating applications. This paper focuses on identifying the collector parameters which are required as the coefficients to configure such an unglazed collector for calibrating its mathematical model within the simulation environment. The parameter identification process implies testing the collector for its thermal performance. This paper attempts to provide an insight into the dynamic testing of uncovered solar thermal collectors (absorbers), taking into account their prospective operation at nighttime for radiative cooling applications. In this study, the main parameters characterizing the performance of the absorbers for radiative cooling applications are identified and obtained from standardized testing protocol. For this aim, a number of plastic solar absorbers of different designs were tested on the outdoor test-stand facility at HFT-Stuttgart for the characterization of their thermal performance. The testing process was based on the quasi-dynamic test method of the international standard for solar thermal collectors EN ISO 9806. The test database was then used within a mathematical optimization tool (GenOpt) to determine the optimal parameter settings of each absorber under testing. Those performance parameters were significant to compare the thermal performance of the tested absorbers. The coefficients (identified parameters) were used then to plot the thermal efficiency curves of all absorbers, for both the heating and cooling modes of operation. Based on the intended main scope of the system utilization (heating or cooling), the tested absorbers could be benchmarked. Hence, one of those absorbers was selected to be used in the following simulation phase as was planned in the research-project.
During the first years of the last decade, Egypt used to face recurrent electricity cut-offs in summer. In the past few years, the electricity tariff dramatically increased. Radiative cooling to the clear night sky is a renewable energy source that represents a relative solution. The dry desert climate promotes nocturnal radiative cooling applications. This study investigates the potential of nocturnal radiative cooling systems (RCSs) to reduce the energy consumption of the residential building sector in Egypt. The system technology proposed in this work is based on uncovered solar thermal collectors integrated into the building hydronic system. By implementing different control strategies, the same system could be used for both cooling and heating applications. The goal of this paper is to analyze the performance of RCSs in residential buildings in Egypt. The dynamic simulation program TRNSYS was used to simulate the thermal behavior of the system. The relevant issues of Egypt as a case-study are firstly overviewed. Then the paper introduces the work done to develop a building model that represents a typical residential apartment in Egypt. Typical occupancy profiles were developed to define the internal thermal gains. The adopted control strategy to optimize the system operation is presented as well. To fully understand and hence evaluate the operation of the proposed RCS, four simulation cases were considered: 1. a reference case (fully passive), 2. the stand-alone operation of the RCS, 3. ideal heating & cooling operation (fully-active), and 4. the hybrid-operation (when the active cooling system is supported by the proposed RCS). The analysis considered the main three distinct climates in Egypt, represented by the cities of Alexandria, Cairo and Asyut. The hotter and drier weather conditions resulted in a higher cooling potential and larger temperature differences. The simulated cooling power in Asyut was 28.4 W/m² for a 70 m² absorber field. For a smaller field area of 10 m², the cooling power reached 109 W/m² but with humble temperature differences. To meet the rigorous thermal comfort conditions, the proposed sensible RCS cannot fully replace conventional air-conditioning units, especially in humid areas like Alexandria. When working in a hybrid system, a 10% reduction in the active cooling energy demand could be achieved in Asyut to keep the cooling set-point at 24 °C. This percentage reduction was nearly doubled when the thermal comfort set-point was increased by two degrees (26 °C). In a sensitivity analysis, external shading devices as a passive measure as well as the implementation of the Egyptian code for buildings (ECP306/1–2005) were also investigated. The analysis of this study raised other relevant aspects to discuss, e.g. system-sizing, environmental effects, limitations and recommendations.
Monitoring heart rate and breathing is essential in understanding the physiological processes for sleep analysis. Polysomnography (PSG) system have traditionally been used for sleep monitoring, but alternative methods can help to make sleep monitoring more portable in someone's home. This study conducted a series of experiments to investigate the use of pressure sensors placed under the bed as an alternative to PSG for monitoring heart rate and breathing during sleep. The following sets of experiments involved the addition of small rubber domes - transparent and black - that were glued to the pressure sensor. The resulting data were compared with the PSG system to determine the accuracy of the pressure sensor readings. The study found that the pressure sensor provided reliable data for extracting heart rate and respiration rate, with mean absolute errors (MAE) of 2.32 and 3.24 for respiration and heart rate, respectively. However, the addition of small rubber hemispheres did not significantly improve the accuracy of the readings, with MAEs of 2.3 bpm and 7.56 breaths per minute for respiration rate and heart rate, respectively. The findings of this study suggest that pressure sensors placed under the bed may serve as a viable alternative to traditional PSG systems for monitoring heart rate and breathing during sleep. These sensors provide a more comfortable and non-invasive method of sleep monitoring. However, the addition of small rubber domes did not significantly enhance the accuracy of the readings, indicating that it may not be a worthwhile addition to the pressure sensor system.
The performance and scalability of modern data-intensive systems are limited by massive data movement of growing datasets across the whole memory hierarchy to the CPUs. Such traditional processor-centric DBMS architectures are bandwidth- and latency-bound. Processing-in-Memory (PIM) designs seek to overcome these limitations by integrating memory and processing functionality on the same chip. PIM targets near- or in-memory data processing, leveraging the greater in-situ parallelism and bandwidth.
In this paper, we introduce pimDB and provide an initial comparison of processor-centric and PIM-DBMS approaches under different aspects, such as scalability and parallelism, cache-awareness, or PIM-specific compute/bandwidth tradeoffs. The evaluation is performed end-to-end on a real PIM hardware system from UPMEM.
Large critical systems, such as those created in the space domain, are usually developed by a large number of organizations and, furthermore, they have to comply with standards. Yet, the different stakeholders often do not have a common understanding of the needed quality of requirements specifications. Achieving such a common understanding is a laborious process that is currently not sufficiently supported. Moreover, such a common understanding must be aligned with the standards. In this paper, we present an approach that can be used to align the different stakeholder perceptions regarding the quality of requirements specifications. Existing quality models for requirements specifications are analyzed for equivalences, and transferred into a common representation, the so-called Aligned Quality Map (AQM). Furthermore, a process is defined that supports the alignment of different stakeholder perspectives with regard to the quality of requirements specifications using AQM, which is validated in a case study in the context of European space projects. AQM has been created and populated with an initial set of quality models. It is designed in such way that it can be extended to include further quality models. The case study has shown that an alignment of different stakeholder perspectives and the quality model of the European Cooperation for Space Standardization using AQM is feasible. The approach allows for aligning different stakeholder perspectives for a common understanding of the quality of requirements specifications in the context of standards. Furthermore, AQM supports the assessment of requirements specifications.
Context
Web APIs are one of the most used ways to expose application functionality on the Web, and their understandability is important for efficiently using the provided resources. While many API design rules exist, empirical evidence for the effectiveness of most rules is lacking.
Objective
We therefore wanted to study 1) the impact of RESTful API design rules on understandability, 2) if rule violations are also perceived as more difficult to understand, and 3) if demographic attributes like REST-related experience have an influence on this.
Method
We conducted a controlled Web-based experiment with 105 participants, from both industry and academia and with different levels of experience. Based on a hybrid between a crossover and a between-subjects design, we studied 12 design rules using API snippets in two complementary versions: one that adhered to a rule and one that was a violation of this rule. Participants answered comprehension questions and rated the perceived difficulty.
Results
For 11 of the 12 rules, we found that violation performed significantly worse than rule for the comprehension tasks. Regarding the subjective ratings, we found significant differences for 9 of the 12 rules, meaning that most violations were subjectively rated as more difficult to understand. Demographics played no role in the comprehension performance for violation.
Conclusions
Our results provide first empirical evidence for the importance of following design rules to improve the understandability of Web APIs, which is important for researchers, practitioners, and educators.
Sleep is extremely important for physical and mental health. Although polysomnography is an established approach in sleep analysis, it is quite intrusive and expensive. Consequently, developing a non-invasive and non-intrusive home sleep monitoring system with minimal influence on patients, that can reliably and accurately measure cardiorespiratory parameters, is of great interest. The aim of this study is to validate a non-invasive and unobtrusive cardiorespiratory parameter monitoring system based on an accelerometer sensor. This system includes a special holder to install the system under the bed mattress. The additional aim is to determine the optimum relative system position (in relation to the subject) at which the most accurate and precise values of measured parameters could be achieved. The data were collected from 23 subjects (13 males and 10 females). The obtained ballistocardiogram signal was sequentially processed using a sixth-order Butterworth bandpass filter and a moving average filter. As a result, an average error (compared to reference values) of 2.24 beats per minute for heart rate and 1.52 breaths per minute for respiratory rate was achieved, regardless of the subject’s sleep position. For males and females, the errors were 2.28 bpm and 2.19 bpm for heart rate and 1.41 rpm and 1.30 rpm for respiratory rate. We determined that placing the sensor and system at chest level is the preferred configuration for cardiorespiratory measurement. Further studies of the system’s performance in larger groups of subjects are required, despite the promising results of the current tests in healthy subjects.
Sleep is an essential part of human existence, as we are in this state for approximately a third of our lives. Sleep disorders are common conditions that can affect many aspects of life. Sleep disorders are diagnosed in special laboratories with a polysomnography system, a costly procedure requiring much effort for the patient. Several systems have been proposed to address this situation, including performing the examination and analysis at the patient's home, using sensors to detect physiological signals automatically analysed by algorithms. This work aims to evaluate the use of a contactless respiratory recording system based on an accelerometer sensor in sleep apnea detection. For this purpose, an installation mounted under the bed mattress records the oscillations caused by the chest movements during the breathing process. The presented processing algorithm performs filtering of the obtained signals and determines the apnea events presence. The performance of the developed system and algorithm of apnea event detection (average values of accuracy, specificity and sensitivity are 94.6%, 95.3%, and 93.7% respectively) confirms the suitability of the proposed method and system for further ambulatory and in-home use.
Sleep is essential to physical and mental health. However, the traditional approach to sleep analysis—polysomnography (PSG)—is intrusive and expensive. Therefore, there is great interest in the development of non-contact, non-invasive, and non-intrusive sleep monitoring systems and technologies that can reliably and accurately measure cardiorespiratory parameters with minimal impact on the patient. This has led to the development of other relevant approaches, which are characterised, for example, by the fact that they allow greater freedom of movement and do not require direct contact with the body, i.e., they are non-contact. This systematic review discusses the relevant methods and technologies for non-contact monitoring of cardiorespiratory activity during sleep. Taking into account the current state of the art in non-intrusive technologies, we can identify the methods of non-intrusive monitoring of cardiac and respiratory activity, the technologies and types of sensors used, and the possible physiological parameters available for analysis. To do this, we conducted a literature review and summarised current research on the use of non-contact technologies for non-intrusive monitoring of cardiac and respiratory activity. The inclusion and exclusion criteria for the selection of publications were established prior to the start of the search. Publications were assessed using one main question and several specific questions. We obtained 3774 unique articles from four literature databases (Web of Science, IEEE Xplore, PubMed, and Scopus) and checked them for relevance, resulting in 54 articles that were analysed in a structured way using terminology. The result was 15 different types of sensors and devices (e.g., radar, temperature sensors, motion sensors, cameras) that can be installed in hospital wards and departments or in the environment. The ability to detect heart rate, respiratory rate, and sleep disorders such as apnoea was among the characteristics examined to investigate the overall effectiveness of the systems and technologies considered for cardiorespiratory monitoring. In addition, the advantages and disadvantages of the considered systems and technologies were identified by answering the identified research questions. The results obtained allow us to determine the current trends and the vector of development of medical technologies in sleep medicine for future researchers and research.
Smart cities are considered data factories that generate an enormous amount of data from various sources. In fact data is the backbone of any smart services. Therefore, the strategic beneficial handling of this digital capital is crucial for cities. Some smart city pioneers have already written down their approach to data in the form of data strategies, but what should a city's data strategy include, and how can the goals and measures defined in the strategies be operationalized? This paper addresses these questions by looking closely at the data strategies of cities in Germany and the top three countries in the EU Digital Economy and Society Index. The in-depth analysis of 8 city data strategies has yielded 11 dimensions that cities should consider in their data strategy. These are relevance of data, principles, methods, data sharing, technology, data culture, data ethics, organizational structure, data security and privacy, collaborations, data literacy. In addition, data governance is a concept to put these 11 strategic dimensions into practice through standardization measures, training programs, and defining roles and responsibilities by developing a data catalog.