Informatik
Refine
Document Type
- Conference proceeding (62) (remove)
Is part of the Bibliography
- yes (62)
Institute
- Informatik (62)
- Technik (1)
Publisher
Evaluation of a contactless accelerometer sensor system for heart rate monitoring during sleep
(2024)
The monitoring of a patient's heart rate (HR) is critical in the diagnosis of diseases. In the detection of sleep disorders, it also plays an important role. Several techniques have been proposed, including using sensors to record physiological signals that are automatically examined and analysed. This work aims to evaluate using a contactless HR monitoring system based on an accelerometer sensor during sleep. For this purpose, the oscillations caused by chest movements during heart contractions are recorded by an installation mounted under the bed mattress. The processing algorithm presented in this paper filters the signals and determines the HR. As a result, an average error of about 5 bpm has been documented, i.e., the system can be considered to be used for the forecasted domain.
Menopause is the permanent cessation of menstruation occurring naturally in women's aging. The most frequent symptoms associated with menopausal phases are mucosal dryness, increased weight and body fat, and changes in sleep patterns. Oral symptoms in menopause derived from saliva flow reduction can lead to dry mouth, ulcers, and alterations of taste and swallowing patterns. However, the oral health phenotype of postmenopausal women has not been characterized. The aim of the study was to determine postmenopausal women's oral phenotype, including medical history, lifestyle, and oral assessment through artificial intelligence algorithms. We enrolled 100 postmenopausal women attending the Dental School of the University of Seville were included in the study. We collected an extensive questionnaire, including lifestyle, medication, and medical history. We used an unsupervised k-means algorithm to cluster the data following standard features for data analysis. Our results showed the main oral symptoms in our postmenopausal cohort were reduced salivary flow and periodontal disease. Relying on the classical assessment of the collected data, we might have a biased evaluation of postmenopausal women. Then, we used artificial intelligence analysis to evaluate our data obtaining the main features and providing a reduced feature defining the oral health phenotype. We found 6 clusters with similar features, including medication affecting salivation or smoking as essential features to obtain different phenotypes. Thus, we could obtain main features considering differential oral health phenotypes of postmenopausal women with an integrative approach providing new tools to assess the women in the dental clinic.
Measuring cardiorespiratory parameters in sleep, using non-contact sensors and the Ballistocardiography technique has received much attention due to the low-cost, unobtrusive, and non-invasive method. Designing a user-friendly, simple-to-use, and easy-to-deployment preserving less error-prone remains open and challenging due to the complex morphology of the signal. In this work, using four forcesensitive resistor sensors, we conducted a study by designing four distributions of sensors, in order to simplify the complexity of the system by identifying the region of interest for heartbeat and respiration measurement. The sensors are deployed under the mattress and attached to the bed frame without any interference with the subjects. The four distributions are combined in two linear horizontal, one linear vertical, and one square, covering the influencing region in cardiorespiratory activities. We recruited 4 subjects and acquired data in four regular sleeping positions, each for a duration of 80 seconds. The signal processing was performed using discrete wavelet transform bior 3.9 and smooth level of 4 as well as bandpass filtering. The results indicate that we have achieved the mean absolute error of 2.35 and 4.34 for respiration and heartbeat, respectively. The results recommend the efficiency of a triangleshaped structure of three sensors for measuring heartbeat and respiration parameters in all four regular sleeping positions.
Identifikation von Schlaf- und Wachzuständen durch die Auswertung von Atem- und Bewegungssignalen
(2021)
The respiratory rate is a vital sign indicating breathing illness. It is necessary to analyze the mechanical oscillations of the patient's body arising from chest movements. An inappropriate holder on which the sensor is mounted, or an inappropriate sensor position is some of the external factors which should be minimized during signal registration. This paper considers using a non-invasive device placed under the bed mattress and evaluates the respiratory rate. The aim of the work is the development of an accelerometer sensor holder for this system. The normal and deep breathing signals were analyzed, corresponding to the relaxed state and when taking deep breaths. The evaluation criterion for the holder's model is its influence on the patient's respiratory signal amplitude for each state. As a result, we offer a non-invasive system of respiratory rate detection, including the mechanical component providing the most accurate values of mentioned respiratory rate.
The purpose of this paper is to examine the effects of perceived stress on traffic and road safety. One of the leading causes of stress among drivers is the feeling of having a lack of control during the driving process. Stress can result in more traffic accidents, an increase in driver errors, and an increase in traffic violations. To study this phenomenon, the Stress Perceived Questionnaire (PSQ) was used to evaluate the perceived stress while driving in a simulation. The study was conducted with participants from Germany, and they were grouped into different categories based on their emotional stability. Each participant was monitored using wearable devices that measured their instantaneous heart rate (HR). The preference for wearable devices was due to their non-intrusive and portable nature. The results of this study provide an overview of how stress can affect traffic and road safety, which can be used for future research or to implement strategies to reduce road accidents and promote traffic safety.
Generating synthetic data is a relevant point in the machine learning community. As accessible data is limited, the generation of synthetic data is a significant point in protecting patients' privacy and having more possibilities to train a model for classification or other machine learning tasks. In this work, some generative adversarial networks (GAN) variants are discussed, and an overview is given of how generative adversarial networks can be used for data generation in different fields. In addition, some common problems of the GANs and possibilities to avoid them are shown. Different evaluation methods of the generated data are also described.
Sleep analysis using a Polysomnography system is difficult and expensive. That is why we suggest a non-invasive and unobtrusive measurement. Very few people want the cables or devices attached to their bodies during sleep. The proposed approach is to implement a monitoring system, so the subject is not bothered. As a result, the idea is a non-invasive monitoring system based on detecting pressure distribution. This system should be able to measure the pressure differences that occur during a single heartbeat and during breathing through the mattress. The system consists of two blocks signal acquisition and signal processing. This whole technology should be economical to be affordable enough for every user. As a result, preprocessed data is obtained for further detailed analysis using different filters for heartbeat and respiration detection. In the initial stage of filtration, Butterworth filters are used.
Determination of accelerometer sensor position for respiration rate detection: initial research
(2022)
Continuous monitoring of a patient's vital signs is essential in many chronic illnesses. The respiratory rate (RR) is one of the vital signs indicating breathing diseases. This article proposes the initial investigation for determining the accelerometric sensor position of a non-invasive and unobtrusive respiratory rate monitoring system. This research aims to determine the sensor position in relation to the patient, which can provide the most accurate values of the mentioned physiological parameter. In order to achieve the result, the particular system setup, including a mechanical sensor holder construction was used. The breathing signals from 5 participants were analyzed corresponding to the relaxed state. The main criterion for selecting a suitable sensor position was each patient's average acceleration amplitude excursion, which corresponds to the respiratory signal. As a result, we provided one more defined important parameter for the considered system, which was not determined before.
Today many scientific works are using deep learning algorithms and time series, which can detect physiological events of interest. In sleep medicine, this is particularly relevant in detecting sleep apnea, specifically in detecting obstructive sleep apnea events. Deep learning algorithms with different architectures are used to achieve decent results in accuracy, sensitivity, etc. Although there are models that can reliably determine apnea and hypopnea events, another essential aspect to consider is the explainability of these models, i.e., why a model makes a particular decision. Another critical factor is how these deep learning models determine how severe obstructive sleep apnea is in patients based on the apnea-hypopnea index (AHI). Deep learning models trained by two approaches for AHI determination are exposed in this work. Approaches vary depending on the data format the models are fed: full-time series and window-based time series.