610 Medizin, Gesundheit
Refine
Document Type
- Conference proceeding (83)
- Journal article (82)
- Book chapter (8)
- Doctoral Thesis (2)
- Book (1)
- Patent / Standard / Guidelines (1)
- Report (1)
Is part of the Bibliography
- yes (178)
Institute
- Informatik (115)
- Life Sciences (47)
- Technik (8)
- ESB Business School (7)
Publisher
Evaluation of a contactless accelerometer sensor system for heart rate monitoring during sleep
(2024)
The monitoring of a patient's heart rate (HR) is critical in the diagnosis of diseases. In the detection of sleep disorders, it also plays an important role. Several techniques have been proposed, including using sensors to record physiological signals that are automatically examined and analysed. This work aims to evaluate using a contactless HR monitoring system based on an accelerometer sensor during sleep. For this purpose, the oscillations caused by chest movements during heart contractions are recorded by an installation mounted under the bed mattress. The processing algorithm presented in this paper filters the signals and determines the HR. As a result, an average error of about 5 bpm has been documented, i.e., the system can be considered to be used for the forecasted domain.
Sleep is extremely important for physical and mental health. Although polysomnography is an established approach in sleep analysis, it is quite intrusive and expensive. Consequently, developing a non-invasive and non-intrusive home sleep monitoring system with minimal influence on patients, that can reliably and accurately measure cardiorespiratory parameters, is of great interest. The aim of this study is to validate a non-invasive and unobtrusive cardiorespiratory parameter monitoring system based on an accelerometer sensor. This system includes a special holder to install the system under the bed mattress. The additional aim is to determine the optimum relative system position (in relation to the subject) at which the most accurate and precise values of measured parameters could be achieved. The data were collected from 23 subjects (13 males and 10 females). The obtained ballistocardiogram signal was sequentially processed using a sixth-order Butterworth bandpass filter and a moving average filter. As a result, an average error (compared to reference values) of 2.24 beats per minute for heart rate and 1.52 breaths per minute for respiratory rate was achieved, regardless of the subject’s sleep position. For males and females, the errors were 2.28 bpm and 2.19 bpm for heart rate and 1.41 rpm and 1.30 rpm for respiratory rate. We determined that placing the sensor and system at chest level is the preferred configuration for cardiorespiratory measurement. Further studies of the system’s performance in larger groups of subjects are required, despite the promising results of the current tests in healthy subjects.
Die Bereitstellung klinischer Informationen im Operationssaal ist ein wichtiger Aspekt zur Unterstützung des chirurgischen Teams. Die roboter-assistierte Ösophagusresektion ist ein besonders komplexer Eingriff, der Potenzial zur workflowbasierten Unterstützung bietet. Wir präsentieren erste Ergebnisse der Entwicklung eines Checklisten-Tools mit der zugrundeliegenden Modellierung des chirurgischen Workflows und Informationsbedarf der Chirurgen. Das Checklisten-Tool zeigt hierfür die durchzuführenden Schritte chronologisch an und stellt zusätzliche Informationen kontextadaptiert bereit. Eine automatische Dokumentation von Start- und Endzeiten einzelner OP-Phasen und Schritte soll zukünftige Prozessanalysen der Operation ermöglichen.
Multi-dimensional patient data, such as time varying volume data, data of different imaging modalities, surface segmentations etc. are of growing importance in the clinical routine. For many use cases, it is of major importance to replicate a certain visualization of a data set created on one machine on a different computer using different software tools. Up until now, there exists no standardized methodology for this consistent presentation. We propose an extension of the Digital Imaging und Communications in Medicine (DICOM) called “Multi dimensional Presentation State” and outline scope and first results of the standardization process.
In order to evaluate the performance of different stapes prosthesis types, a coupled finite element (FE) model of human ear was developed. First, the middle-ear FE model was developed and validated using the middle-ear transfer function measurements available in literature including pathological cases. Then, the inner-ear FE model was developed and validated using tonotopy, impedance, and level of cochlea amplification curves from literature. Both models are based on pre-existing research with some improvements and were combined into one coupled FE model. The stapes in the coupled FE ear model was replaced with a model of a stapes prosthesis to create a reconstructed ear model that can be used to estimate how different types of protheses perform relative to each other as well as to the natural ear. This will help in designing of new innovative types of stapes prostheses or any other type of middle-ear prostheses as well as to improve the ones that are already available on the market.
This study describes a non-contact measuring and parameter identification procedure designed to evaluate inhomogeneous stiffness and damping characteristics of the annular ligament in the physiological amplitude and frequency range without the application of large static external forces that can cause unnatural displacements of the stapes. To verify the procedure, measurements were first conducted on a steel beam. Then, measurements on an individual human cadaveric temporal bone sample were performed. The estimated results support the inhomogeneous stiffness and damping distribution of the annular ligament and are in a good agreement with the multiphoton microscopy results which show that the posterior-inferior corner of the stapes footplate is the stiffest region of the annular ligament. This method can potentially help to establish a correlation between stiffness and damping characteristics of the annular ligament and inertia properties of the stapes and, thus, help to reduce the number of independent parameters in the model-based hearing diagnosis.
Motivation: Aim of this project is the automatic classification of total hip endoprosthesis (THEP) components in 2D Xray images. Revision surgeries of total hip arthroplasty (THA) are common procedures in orthopedics and trauma surgery. Currently, around 400.000 procedures per year are performed in the United States (US) alone. To achieve the best possible result, preoperative planning is crucial. Especially if parts of the current THEP system are to be retained.
Methods: First, a ground truth based on 76 X-ray images was created: We used an image processing pipeline consisting of a segmentation step performed by a convolutional neural network and a classification step performed by a support vector machine (SVM). In total, 11 classes (5 pans and 6 shafts) shall be classified.
Results: The ground truth generated was of good quality even though the initial segmentation was performed by technicians. The best segmentation results were achieved using a U-net architecture. For classification, SVM architectures performed much better than additional neural networks.
Conclusions: The overall image processing pipeline performed well, but the ground truth needs to be extended to include a broader variability of implant types and more examples per training class.
Perceptual integration of kinematic components in the recognition of emotional facial expressions
(2018)
According to a long-standing hypothesis in motor control, complex body motion is organized in terms of movement primitives, reducing massively the dimensionality of the underlying control problems. For body movements, this low dimensional organization has been convincingly demonstrated by the learning of low-dimensional representations from kinematic and EMG data. In contrast, the effective dimensionality of dynamic facial expressions is unknown, and dominant analysis approaches have been based on heuristically defined facial ‘‘action units,’’ which reflect contributions of individual face muscles. We determined the effective dimensionality of dynamic facial expressions by learning of a low dimensional model from 11 facial expressions. We found an amazingly low dimensionality with only two movement primitives being sufficient to simulate these dynamic expressions with high accuracy. This low dimensionality is confirmed statistically, by Bayesian model comparison of models with different numbers of primitives, and by a psychophysical experiment that demonstrates that expressions, simulated with only two primitives, are indistinguishable from natural ones.
In addition, we find statistically optimal integration of the emotion information specified by these primitives in visual perception. Taken together, our results indicate that facial expressions might be controlled by a very small number of independent control units, permitting very low dimensional parametrization of the associated facial expression.
The ballistocardiography is a technique that measures the heart rate from the mechanical vibrations of the body due to the heart movement. In this work a novel noninvasive device placed under the mattress of a bed estimates the heart rate using the ballistocardiography. Different algorithms for heart rate estimation have been developed.
Personalized remote healthcare monitoring is in continuous development due to the technology improvements of sensors and wearable electronic systems. A state of the art of research works on wearable sensors for healthcare applications is presented in this work. Furthermore, a state of the art of wearable devices, chest and wrist band and smartwatches available on the market for health and sport monitoring is presented in this paper. Many activity trackers are commercially available. The prices are continuously reducing and the performances are improving, but commercial devices do not provide raw data and are therefore not useful for research purposes.