610 Medizin, Gesundheit
Refine
Document Type
- Conference proceeding (83)
- Journal article (82)
- Book chapter (8)
- Doctoral Thesis (2)
- Book (1)
- Patent / Standard / Guidelines (1)
- Report (1)
Is part of the Bibliography
- yes (178)
Institute
- Informatik (115)
- Life Sciences (47)
- Technik (8)
- ESB Business School (7)
Publisher
- Springer (47)
- Hochschule Reutlingen (17)
- IOP Publishing (10)
- Università Politecnica delle Marche (9)
- Deutsche Gesellschaft für Computer- und Roboterassistierte Chirurgie e.V. (8)
- Elsevier (8)
- MDPI (7)
- De Gruyter (6)
- IEEE (6)
- SPIE. The International Society for Optical Engineering (5)
- Sage Publishing (4)
- University of Colorado (4)
- Deutsche Gesellschaft für Computer- und Roboterassistierte Chirurgie e. V. (3)
- PLOS (3)
- Taylor & Francis (3)
- GMDS e.V. (2)
- IIAR (2)
- Lippincott Williams & Wilkins (2)
- Thieme (2)
- Wiley (2)
- AOK-Bundesverband (1)
- ARVO (1)
- AlTEX Edition (1)
- American Institute of Physics (1)
- Curran Associates Inc. (1)
- Cuvillier Verlag (1)
- DGMP (1)
- Editio Cantor Verlag (1)
- Frontiers Research Foundation (1)
- Hindawi (1)
- JMIR Publications (1)
- Koordinierungsstelle Forschung und Entwicklung der Fachhochschulen des Landes Baden-Württemberg (1)
- Mediengruppe Oberfranken (1)
- Morressier (1)
- NextMed (1)
- Oemus Media (1)
- Pabst Science Publishers (1)
- Pan Stanford Publishing (1)
- PeerJ Inc. (1)
- Universität Leipzig (1)
Background: One of the most promising health care development areas is introducing telemedicine services and creating solutions based on blockchain technology. The study of systems combining both these domains indicates the ongoing expansion of digital technologies in this market segment.
Objective: This paper aims to review the feasibility of blockchain technology for telemedicine.
Methods: The authors identified relevant studies via systematic searches of databases including PubMed, Scopus, Web of Science, IEEE Xplore, and Google Scholar. The suitability of each for inclusion in this review was assessed independently. Owing to the lack of publications, available blockchain-based tokens were discovered via conventional web search engines (Google, Yahoo, and Yandex).
Results: Of the 40 discovered projects, only 18 met the selection criteria. The 5 most prevalent features of the available solutions (N=18) were medical data access (14/18, 78%), medical service processing (14/18, 78%), diagnostic support (10/18, 56%), payment transactions (10/18, 56%), and fundraising for telemedical instrument development (5/18, 28%).
Conclusions: These different features (eg, medical data access, medical service processing, epidemiology reporting, diagnostic support, and treatment support) allow us to discuss the possibilities for integration of blockchain technology into telemedicine and health care on different levels. In this area, a wide range of tasks can be identified that could be accomplished based on digital technologies using blockchains.
The main aim of presented in this manuscript research is to compare the results of objective and subjective measurement of sleep quality for older adults (65+) in the home environment. A total amount of 73 nights was evaluated in this study. Placing under the mattress device was used to obtain objective measurement data, and a common question on perceived sleep quality was asked to collect the subjective sleep quality level. The achieved results confirm the correlation between objective and subjective measurement of sleep quality with the average standard deviation equal to 2 of 10 possible quality points.
The present work proposes the use of modern ICT technologies such as smartphones, NFCs, internet, and web technologies, to help patients in carrying out their therapies. The implemented system provides a calendar with a reminder of the assumptions, ensures the drug identification through NFC, allows remote assistance from healthcare staff and family members to check and manage the therapy in real-time. The system also provides centralized information on the patient's therapeutic situation, helpful in choosing new compatible therapies.
We investigated the state of artificial intelligence (AI) in pharmaceutical research and development (R&D) and outline here a risk and reward perspective regarding digital R&D. Given the novelty of the research area, a combined qualitative and quantitative research method was chosen, including the analysis of annual company reports, investor relations information, patent applications, and scientific publications of 21 pharmaceutical companies for the years 2014 to 2019. As a result, we can confirm that the industry is in an ‘early mature’ phase of using AI in R&D. Furthermore, we can demonstrate that, despite the efforts that need to be managed, recent developments in the industry indicate that it is worthwhile to invest to become a ‘digital pharma player’.
It has been widely shown that biomaterial surface topography can modulate host immune response, but a fundamental understanding of how different topographies contribute to pro-inflammatory or anti-inflammatory responses is still lacking. To investigate the impact of surface topography on immune response, we undertook a systematic approach by analyzing immune response to eight grades of medical grade polyurethane of increasing surface roughness in three in vitro models of the human immune system. Polyurethane specimens were produced with defined roughness values by injection molding according to the VDI 3400 industrial standard. Specimens ranged from 0.1 μm to 18 μm in average roughness (Ra), which was confirmed by confocal scanning microscopy. Immunological responses were assessed with THP-1-derived macrophages, human peripheral blood mononuclear cells (PBMCs), and whole blood following culture on polyurethane specimens. As shown by the release of pro-inflammatory and anti-inflammatory cytokines in all three models, a mild immune response to polyurethane was observed, however, this was not associated with the degree of surface roughness. Likewise, the cell morphology (cell spreading, circularity, and elongation) in THP-1-derived macrophages and the expression of CD molecules in the PBMC model on T cells (HLA-DR and CD16), NK cells (HLA-DR), and monocytes (HLA-DR, CD16, CD86, and CD163) showed no influence of surface roughness. In summary, this study shows that modifying surface roughness in the micrometer range on polyurethane has no impact on the pro-inflammatory immune response. Therefore, we propose that such modifications do not affect the immunocompatibility of polyurethane, thereby supporting the notion of polyurethane as a biocompatible material.
The recovery of our body and brain from fatigue directly depends on the quality of sleep, which can be determined from the results of a sleep study. The classification of sleep stages is the first step of this study and includes the measurement of vital data and their further processing. The non-invasive sleep analysis system is based on a hardware sensor network of 24 pressure sensors providing sleep phase detection. The pressure sensors are connected to an energy-efficient microcontroller via a system-wide bus. A significant difference between this system and other approaches is the innovative way in which the sensors are placed under the mattress. This feature facilitates the continuous use of the system without any noticeable influence on the sleeping person. The system was tested by conducting experiments that recorded the sleep of various healthy young people. Results indicate the potential to capture respiratory rate and body movement.
Methods based exclusively on heart rate hardly allow to differentiate between physical activity, stress, relaxation, and rest, that is why an additional sensor like activity/movement sensor added for detection and classification. The response of the heart to physical activity, stress, relaxation, and no activity can be very similar. In this study, we can observe the influence of induced stress and analyze which metrics could be considered for its detection. The changes in the Root Mean Square of the Successive Differences provide us with information about physiological changes. A set of measurements collecting the RR intervals was taken. The intervals are used as a parameter to distinguish four different stages. Parameters like skin conductivity or skin temperature were not used because the main aim is to maintain a minimum number of sensors and devices and thereby to increase the wearability in the future.
The ballistocardiography is a technique that measures the heart rate from the mechanical vibrations of the body due to the heart movement. In this work a novel noninvasive device placed under the mattress of a bed estimates the heart rate using the ballistocardiography. Different algorithms for heart rate estimation have been developed.
Artificial intelligence (AI) technologies, such as machine learning or deep learning, have been predicted to highly impact future organizations and radically change the way how projects are managed. The Project Management Institute (PMI), the network of around 1.1 million certified project managers, ranked AI as one of the top three disruptors of their profession. In an own study on the effect of AI, 37% of the project management processes can be executed by machine learning and other AI technologies. In addition, Gartner recently postulated that 80% of the work of today's project managers may be eliminated by AI in 2030.
This editorial aims to outline today's project and portfolio management in context of pharmaceutical research and development (R&D), followed by an AI-vision and a more tangible mission, and illustrate what the consequences of an AI-enabled project and portfolio management could be for pharmaceutical R&D.
Die rasante Entwicklung der Sensortechnik im Endverbraucherbereich lässt einen klinischen Nutzen der verfügbaren dezentral erhobenen Daten aus dem Patientenalltag zur Überwachung des individuellen Gesundheitszustands vermuten. Zur Überprüfung dieser Vermutung ist die Bereitstellung einer entsprechenden Plattform in den klinischen Alltag erforderlich. Hierzu wird die bwHealthApp entwickelt, mit der sowohl die aktuelle Bandbreite als auch die Evolution der Sensortechnik auf die klinische Anwendung abbildbar ist. Mit dem flexiblen Entwurf lässt sich der klinische Nutzen für die personalisierte Medizin evaluieren. Außerdem bietet die bwHealthApp einen an Machbarkeit orientierten Diskussionsbeitrag zu offenen rechtlichen, regulatorischen und ethischen Fragestellungen der Digitalisierung in der Medizin in Deutschland.
The aim of this work was to investigate the mean fill weight control of a continuous capsule-filling process, whether it is possible to derive controller settings from an appendant process model. To that end, a system composed out of fully automated capsule filler and an online gravimetric scale was used to control the filled weight. This setup allows to examine challenges associated with continuous manufacturing processes, such as variations in the amount of active pharmaceutical ingredient (API) in the mixture due to fluctuations of the feeders or due to altered excipient batch qualities. Two types of controllers were investigated: a feedback control and a combination of feedback and feedforward control. Although both of those are common in the industry, determining the optimal parameter settings remains an issue. In this study, we developed a method to derive the control parameters based on process models in order to obtain optimal control for each filled product. Determined via rapid automated process development (RAPD), this method is an effective and fast way of determining control parameters. The method allowed us to optimize the weight control for three pharmaceutical excipients. By conducting experiments, we verified the feasibility of the proposed method and studied the dynamics of the controlled system. Our work provides important basic data on how capsule filler can be implemented into continuous manufacturing systems.
In networked operating room environments, there is an emerging trend towards standardized non-proprietary communication protocols which allow to build new integration solutions and flexible human-machine interaction concepts. The most prominent endeavor is the IEEE 11073 SDC protocol. For some uses cases, it would be helpful if not just medical devices could be controlled based on SDC, but also building automation systems like light, shutters, air condition, etc. For those systems, the KNX protocol is widely used. We build an SDC-to-KNX gateway which allows to use the SDC protocol for sending commands to connected KNX devices. The first prototype system was successfully implemented at the demonstration operating room at Reutlingen University. This is a first step toward the integration of a broader variety of KNX devices.
Documentation of clinical processes, especially in the perioperative are, is a base requirement for quality of service. Nonetheless, the documentation is a burden for the medical staff since it distracts from the clinical core process. An intuitive and user-friendly documentation system could increase documentation quality and reduce documentation workload. The optimal system solution would know what happened and the person documenting the step would need a single “confirm” button. In many cases, such a linear flow of activities is given as long as only one profession (e.g. anaestesiology, scrub nurse) is considered, but even in such cases, there might be derivations from the linear process flow and further interaction is required.
Intraoperative brain deformation, so called brain shift, affects the applicability of preoperative magnetic resonance imaging (MRI) data to assist the procedures of intraoperative ultrasound (iUS) guidance during neurosurgery. This paper proposes a deep learning-based approach for fast and accurate deformable registration of preoperative MRI to iUS images to correct brain shift. Based on the architecture of 3D convolutional neural networks, the proposed deep MRI-iUS registration method has been successfully tested and evaluated on the retrospective evaluation of cerebral tumors (RESECT) dataset. This study showed that our proposed method outperforms other registration methods in previous studies with an average mean squared error (MSE) of 85. Moreover, this method can register three 3D MRI-US pair in less than a second, improving the expected outcomes of brain surgery.
Checklists are a valuable tool to ensure process quality and quality of care. To ensure proper integration in clinical processes, it would be desirable to generate checklists directly from formal process descriptions. Those checklists could also be used for user interaction in context-aware surgical assist systems. We built a tool to automatically convert Business Process Model and Notation (BPMN) process models to checklists displayed as HTML websites. Gateways representing decisions are mapped to checklist items that trigger dynamic content loading based on the placed checkmark. The usability of the resulting system was positively evaluated regarding comprehensibility and end-user friendliness.
Pharmaceutical companies are among the top investors into research and development (R&D) globally, as product innovation is still the main growth driver for the industry and because the related complexities necessitate enormous R&D investments. The market demand for new medicines to be more efficacious or to provide better safety than existing drugs and the regulatory need to prove superiority in clinical trials are reasons why drug R&D is increasingly expensive and pharmaceutical companies need to manage extraordinarily high costs per approved new compound.
Purpose: Gliomas are the most common and aggressive type of brain tumors due to their infiltrative nature and rapid progression. The process of distinguishing tumor boundaries from healthy cells is still a challenging task in the clinical routine. Fluid attenuated inversion recovery (FLAIR) MRI modality can provide the physician with information about tumor infiltration. Therefore, this paper proposes a new generic deep learning architecture, namely DeepSeg, for fully automated detection and segmentation of the brain lesion using FLAIR MRI data.
Methods: The developed DeepSeg is a modular decoupling framework. It consists of two connected core parts based on an encoding and decoding relationship. The encoder part is a convolutional neural network (CNN) responsible for spatial information extraction. The resulting semantic map is inserted into the decoder part to get the full-resolution probability map. Based on modified U-Net architecture, different CNN models such as residual neural network (ResNet), dense convolutional network (DenseNet), and NASNet have been utilized in this study.
Results: The proposed deep learning architectures have been successfully tested and evaluated on-line based on MRI datasets of brain tumor segmentation (BraTS 2019) challenge, including s336 cases as training data and 125 cases for validation data. The dice and Hausdorff distance scores of obtained segmentation results are about 0.81 to 0.84 and 9.8 to 19.7 correspondingly.
Conclusion: This study showed successful feasibility and comparative performance of applying different deep learning models in a new DeepSeg framework for automated brain tumor segmentation in FLAIR MR images. The proposed DeepSeg is open source and freely available at https://github.com/razeineldin/DeepSeg/.
In Zusammenarbeit mit dem Medizinproduktehersteller ulrich medical wird eine User Experience und Usability Studie an der Software der im Moment eingesetzten Kontrastmittelinjektoren durchgeführt. Das Unternehmen möchte eine neue Variante eines Kontrastmittelinjektors entwickeln, der als Basis eine verbesserte Version dieser Softwares enthält. Benutzerstudien können mit den unterschiedlichsten Methoden durchgeführt werden. Das geeignete Vorgehen muss definiert und die Testpersonen in Bezug zur eingesetzten Methode ermittelt werden. Bei Medizinprodukten muss zusätzlich auf strikte Auflagen in Normen und Gesetzen geachtet werden. Die Grundlage zur Methodenauswahl bildet eine Recherche zu Usability und User Experience Vorgaben für Medizinprodukte. Die Studie wird anhand quantitativer Daten eines Usability Tests im Labor, Fragebögen zur User Experience und qualitativen Post Test- Interviews evaluiert. In erster Linie dient diese Studie der Ermittlung von möglichen Verbesserungen, welche in der darauf folgenden Masterthesis vertieft und umgesetzt werden.
The field of breath analysis has developed to be of growing interest in medical diagnosis and patient monitoring. The main advantages are that it’s noninvasive, painless and repeatable in flexible cycles. Even though breath analysis is being researched for a couple of decades there are still many unanswered questions. Human breath contains volatile organic compounds which are emitted from inside the body. Some of these compounds can be assigned to specific sources, such as inflammation or cancer, but also to non health related origins. This paper gives an overview of breath analysis for the purpose of disease diagnosis and health monitoring. Therefore, literature regarding breath analysis in the medical field has been analyzed, from its early stages to the present. As a result, this paper gives an outline of the topic of breath analysis.
Haptisches Feedback ist nach zahlreichen Studien ein wichtiger Bestandteil in der medizinischen Robotik. Die meisten Systeme befinden sich jedoch noch im Forschungsstatus und verfolgen unterschiedliche Ansätze. In der Teleoperation wird mit sensorlosen und Sensor-Systemen geforscht. Sensoren bieten, im Gegensatz zu den Encodern in sensorlosen Systemen, genaue Messungen, sind allerdings teuer in der Anschaffung, schwer zu desinfizieren und müssen in OP-Besteck integriert werden. In Hands-On Systemen fühlt der Operateur im Gegensatz zu Teleoperationssystemen direkt die auftretenden Kräfte bei der Benutzung. Der Roboter bietet in diesen Systemen nur die benötigte Stabilität und Genauigkeit, gesteuert werden sie direkt durch den Menschen. Dagegen werden in Teleoperationssystemen gezielte Controller eingesetzt. Hier hat sich der für den OP entwickelte sigma.7 durchgesetzt. Gegenüber der für die Allgemeinheit entwickelten Konkurrenz bietet er haptisches Feedback in allen nötigen Freiheitsgraden und eine entsprechende Kraftrückkoppelung.